| Plan Review Stops For Permit 22100412 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-12-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-12-01 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-12-01 |
Time |
12:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-11-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-11-22 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-11-22 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2022-11-22 11:31:59 | STAIR REPLACEMENT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE SHOW THE HANDRAIL EXTENSION AT THE TOP TO | | | CONTINUE IN THE SAME DIRECTION AS THE STAIR (ONE SIDE | | | DOES THE OTHER SIDE IS SHOWN TURNING) FBC 1014.6 | | | HANDRAIL EXTENSIONS.THE EXTENSIONS OF HANDRAILS SHALL | | | BE IN THE SAME DIRECTION OF THE FLIGHTS OF STAIRS AT | | | STAIRWAYS AND THE RAMP RUNS AT RAMPS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-11-08 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-11-08 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-11-08 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2022-11-08 10:55:59 | STAIR REPLACEMENT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE PROVIDE A SITE PLAN SHOWING THE LOCATION OF | | | THE STAIR. | | | | | | 2) PLEASE SHOW THE HANDRAIL EXTENSION AT THE TOP TO | | | CONTINUE IN THE SAME DIRECTION AS THE STAIR (ONE SIDE | | | DOES THE OTHER SIDE IS SHOWN TURNING) FBC 1014.6 | | | HANDRAIL EXTENSIONS.THE EXTENSIONS OF HANDRAILS SHALL | | | BE IN THE SAME DIRECTION OF THE FLIGHTS OF STAIRS AT | | | STAIRWAYS AND THE RAMP RUNS AT RAMPS. | | | | | | 3) IF A WALKING PATH IS UNDER THE STAIR PLEASE SHOW | | | COMPLIANCE WITH FBC ACCESSIBILITY 307.4 VERTICAL | | | CLEARANCE. | | | VERTICAL CLEARANCE SHALL BE 80 INCHES (2030 MM) HIGH | | | MINIMUM. GUARDRAILS OR OTHER BARRIERS SHALL BE PROVIDED | | | WHERE THE VERTICAL CLEARANCE IS LESS THAN 80 INCHES | | | (2030 MM) HIGH. THE LEADING EDGE OF SUCH GUARDRAIL OR | | | BARRIER SHALL BE LOCATED 27 INCHES (685 MM) MAXIMUM | | | ABOVE THE FINISH FLOOR OR GROUND. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2022-11-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-11-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-11-30 |
Time |
12:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-11-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-11-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-11-18 |
Time |
11:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2022-10-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-10-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-10-17 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2022-10-17 15:36:37 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE IS AN INDICATION OF AN EXIT STARIWAY AT THE | | | PROVIDED ADDRESS BUT THERE IS NOT SITE PLAN SHOWING THE | | | LOCATION AND/OR ORIENATION TO THE BUILDING. | | | | | | FOR THE OFFICIAL RECORD, PLEASE PROVIDE THE A SITE PLAN | | | SHOWING THE LOCATION OF THE STAIR. | | | | | | | | | 2) THERE IS NO INDICATION OF THE EXISTING STAIR | | | DIMENSIONS. | | | | | | PLEASE PROVIDE THE EXISTING STAIR DIMENSIONS INDICATING | | | THAT THESE NEW STAIRS MEET OR EXCEED THE EXISTING | | | STAIRS. | | | | | | OR PROVIDE A LIFE SAFETY PLAN INDICATING THE OCCUPANCY | | | LOAD OF THE 2ND FLOOR AND THAT THESE NEW STAIRS MEETS | | | OR EXCEEDS THE EXITING REQUIREMENTS OF NFPA 101 CH | | | 12/13. | | | | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-10-20 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-10-20 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-10-20 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-12-02 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2022-12-02 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2022-11-29 |
Time |
09:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-11-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-11-22 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-11-17 |
Time |
07:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-11-08 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-11-08 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-10-14 |
Time |
07:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-12-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-12-01 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-12-01 |
Time |
12:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-11-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-11-22 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-11-22 |
Time |
11:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-11-08 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-11-08 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-11-08 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-12-01 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2022-12-01 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2022-12-01 |
Time |
16:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-11-21 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2022-11-21 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2022-11-21 |
Time |
08:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-11-08 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2022-11-08 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2022-11-08 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2022-11-08 09:04:18 | 1. ZONING CANNOT PASS REVIEW DUE TO LACK OF SURVEY AND | | | SITE PLAN INDICATING WHERE THE STAIR IS LOCATED ON THE | | | PREMISES. | | | | | | - PLEASE PROVIDE BOTH A SURVEY AND SITE PLAN. | | | | | | CHRIS KIMMERLY, AICP | | | URBAN DESIGN PLANNER | | | [email protected] 822-1426 |
|
|