| Plan Review Stops For Permit 22100260 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-12-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-12-22 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-12-22 |
Time |
16:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-12-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-12-21 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-12-21 |
Time |
16:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-12-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-12-16 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-12-16 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2022-12-16 10:54:57 | BUILDING REVIEW IS APPROVED PENDING APPROVAL OF DIGITAL | | | SIGNATURE REVIEW. CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-11-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-16 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-11-16 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2022-11-16 12:11:15 | 1ST BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: DEMO PLAN INDICATES THE EXTERIOR DOOR AT | | | BEDROOM #2 WILL BE REPLACED. | | | | | | 1.PROVIDE THE FL PRODUCT APPROVALS OR MIAMI-DADE NOA | | | FOR THE PROPOSED EXT. DOOR | | | FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, | | | EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. | | | NOTE: NOAS DO NOT HAVE COVER SHEETS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-12-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-12-22 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-12-22 |
Time |
16:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-12-13 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-12-13 |
Time |
19:52 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-12-13 |
Time |
18:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-10-27 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-10-27 |
Time |
19:32 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-10-26 |
Time |
21:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-12-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-12-22 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-12-21 |
Time |
16:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-12-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-12-16 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-12-07 |
Time |
17:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-11-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-16 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-19 |
Time |
10:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2022-11-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-11-02 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-11-02 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2022-11-02 09:18:11 | NO MECHANICAL WORK SHOWN FOR THIS PROJECT. ME |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2022-12-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-12-21 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-12-21 |
Time |
16:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-12-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-12-09 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-12-09 |
Time |
07:01 |
Sent To |
|
|
| Notes |
| 2022-12-09 07:25:06 | | | | | | | 2ND PLUMBING REVIEW- FBC-2020 | | | 12/9/22 | | | | | | 1) SHEET A-2 WHICH HAS THE PLUMBING RISERS APPEARS TO | | | BE A PRINTED COPY OF THE ORIGINAL DIGITALLY SIGNED AND | | | SEALED PLAN BY THE ENGINEER OF RECORD- FL. STATUTE | | | 471.025, AND SECTION 61G15-23.005 FAC. | | | | | | PLANS PREPARED BY FL. LICENSED ENGINEERS SHALL BEAR | | | ORIGINAL AND VERIFIABLE DIGITAL SEALS AND SIGNATURES OF | | | THE ENGINEER. | | | A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL | | | ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY | | | CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION. | | | THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE | | | A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES | | | NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.) | | | YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE | | | ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT | | | USE A THIRD PARTY. | | | YOUR DIGITAL SIGNATURE MUST BE LINKED TO THE DOCUMENT | | | IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE SIGNATURE | | | AND DOCUMENT. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | | | | FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR | | | ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND | | | DOCUMENTS. | | | | | | A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL | | | ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY | | | CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION. | | | THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE | | | A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES | | | NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.) | | | YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE | | | ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT | | | USE A THIRD PARTY. | | | YOUR DIGITAL SIGNATURE MUST BE LINKED TO THE DOCUMENT | | | IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE SIGNATURE | | | AND DOCUMENT. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-10-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-10-25 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-10-25 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2022-10-25 10:03:58 | 1ST PLUMBING REVIEW- FBC-2020 | | | 10/25/22 | | | | | | 1) SHEET A-2 WHICH HAS THE PLUMBING RISERS IS NOT | | | DIGITALLY SIGNED AND SEALED BY THE ENGINEER OF RECORD- | | | FL. STATUTE 471.025, AND SECTION 61G15-23.005 FAC. | | | FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR | | | ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND | | | DOCUMENTS. NO CORRECTIONS ARE REQUIRED FOR THE RISERS | | | WHICH ARE IN COMPLIANCE. | | | | | | A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL | | | ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY | | | CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION. | | | THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE | | | A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES | | | NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.) | | | YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE | | | ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT | | | USE A THIRD PARTY. | | | YOUR DIGITAL SIGNATURE MUST BE LINKED TO THE DOCUMENT | | | IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE SIGNATURE | | | AND DOCUMENT. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
P |
Date |
2022-11-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-16 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-11-16 |
Time |
11:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-12-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-12-21 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-12-21 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2022-12-21 16:02:04 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | SIGNATURE REVIEW APPROVED BY PAPER PLAN SHEETS: COVER | | | SHEET, D-1, A-1, A-2, & E-1 COMPLETE WITH ORIGINAL HAND | | | SIGNATURES AND SEALS BY PROFESSIONSL ENGINEER JAIRO A. | | | ROJAS. THE SUBMITTED PAPER PLAN SHEETS HAVE BEEN ROUTED | | | TO THE STORAGE BIN. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-12-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-12-09 |
Time |
07:14 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-12-09 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2022-12-09 07:24:15 | 2ND SIGNATURE REVIEW | | | 12/9/22 | | | | | | 1) 1) THE PLANS APPEAR TO BE PRINTED COPIES OF | | | DIGITALLY SIGNED AND SEALED PLANS BY THE ENGINEER OF | | | RECORD. PLANS PREPARED BY FL. LICENSED ENGINEERS SHALL | | | BEAR ORIGINAL AND VERIFIABLE DIGITAL SEALS AND | | | SIGNATURES OF THE ENGINEER- FL. STATUTE 471.025, AND | | | SECTION 61G15-23.005 FAC. | | | A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL | | | ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY | | | CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION. | | | THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE | | | A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES | | | NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.) | | | YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE | | | ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT | | | USE A THIRD PARTY. | | | YOUR DIGITAL SIGNATURE MUST BE LINKED TO THE DOCUMENT | | | IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE SIGNATURE | | | AND DOCUMENT. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-10-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-10-25 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-10-25 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2022-10-25 09:57:47 | SIGNATURE REVIEW | | | 10/25/22 | | | | | | 1) THE PLAN SHEETS ARE NOT DIGITALLY SIGNED AND SEALED | | | BY THE ENGINEER OF RECORD- FL. STATUTE 471.025, AND | | | SECTION 61G15-23.005 FAC. | | | FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR | | | ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND | | | DOCUMENTS. | | | | | | A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL | | | ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY | | | CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION. | | | THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE | | | A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES | | | NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.) | | | YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE | | | ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT | | | USE A THIRD PARTY. | | | YOUR DIGITAL SIGNATURE MUST BE LINKED TO THE DOCUMENT | | | IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE SIGNATURE | | | AND DOCUMENT. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|