Plan Review Details - Permit 22100243
Plan Review Stops For Permit 22100243
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-11-15 Cont ID  
Sent By cpuell Date 2022-11-15 Time 12:17 Rev Time 0.00
Received By cpuell Date 2022-11-15 Time 12:17 Sent To  
Notes
2022-11-15 12:19:13ADDRESS APPROPRIATE FOR PROJECT.

Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-12-09 Cont ID  
Sent By rmcphers Date 2022-12-09 Time 16:22 Rev Time 0.00
Received By rmcphers Date 2022-12-09 Time 16:11 Sent To  
Notes
2022-12-09 16:18:38NEW METAL BUILDING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW WHAT THE BUILDING WILL BE USED FOR - FBC
 302.1 OCCUPANCY CLASSIFICATION.
 OCCUPANCY CLASSIFICATION IS THE FORMAL DESIGNATION OF
 THE PRIMARY PURPOSE OF THE BUILDING, STRUCTURE OR
 PORTION THEREOF. STRUCTURES SHALL BE CLASSIFIED INTO
 ONE OR MORE OF THE OCCUPANCY GROUPS LISTED IN THIS
 SECTION BASED ON THE NATURE OF THE HAZARDS AND RISKS TO
 BUILDING OCCUPANTS GENERALLY ASSOCIATED WITH THE
 INTENDED PURPOSE OF THE BUILDING OR STRUCTURE.
  
 2) PLEASE PROVIDE A SITE PLAN SHOWING THE FOLLOWING
 INFORMATION FBC WPB 107.2.5 SITE PLAN. THE CONSTRUCTION
 DOCUMENTS SUBMITTED WITH THE APPLICATION FOR PERMIT
 SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE
 THE SIZE AND LOCATION OF NEW CONSTRUCTION AND EXISTING
 STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE
 ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED
 GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS
 APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN
 FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE
 WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE
 SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY PROPOSED
 WATER RETAINING SWALES)
  
 3) DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE
 READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED
 TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2022-12-14 Cont ID  
Sent By mpeterso Date 2022-12-14 Time 11:51 Rev Time 0.00
Received By mpeterso Date 2022-12-14 Time 11:06 Sent To  
Notes
2022-12-14 11:52:27NO ELECTRIC WORK SHOWN, REVIEWED OR APPROVED.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2022-11-21 Cont ID  
Sent By rrossano Date 2022-11-21 Time   Rev Time  
Received By rrossano Date 2022-11-21 Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-11-15 Cont ID  
Sent By pleduc Date 2022-11-15 Time   Rev Time 0.00
Received By pleduc Date 2022-11-15 Time 13:18 Sent To  
Notes
2022-11-15 14:31:03THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THERE IS AN INDICATION OF A SURVEY; HOWEVER, THERE
 IS SITE PLAN INDICATING THE PROPOSED LOCATION OF THE
 GARAGE.
  
 PER NFPA 1
  
 1.7.12 PLANS AND SPECIFICATIONS.
  
 1.7.12.1 THE AHJ SHALL HAVE THE AUTHORITY TO REQUIRE
 PLANS AND SPECIFICATIONS TO ENSURE COMPLIANCE WITH
 APPLICABLE CODES AND STANDARDS.
  
 FOR THE OFFICIAL RECORD, PLEASE PROVIDE A SITE PLAN.
  
  
 2) THERE IS NO INDICATION OF THE PROPOSED OCCUPANCY
 CLASSIFICATION.
  
 IT APPEARS TO BE A COMMERCIAL PARKING GARAGE, WHICH
 SHALL COMPLY WITH NFPA 101 CH 42, STORAGE OCCUPANCY
  
 42.2.8 ILLUMINATION OF MEANS OF EGRESS.
 42.2.8.1 MEANS OF EGRESS SHALL BE ILLUMINATED IN
 ACCORDANCE WITH SEC TION 7.8.
 42.2.8.2 IN STRUCTURES OCCUPIED ONLY DURING DAYLIGHT
 HOURS, MEANS OF
 EGRESS SHALL BE PERMITTED TO BE ILLUMINATED WITH
 WINDOWS ARRANGED TO
 PROVIDE THE REQUIRED LEVEL OF ILLUMINATION ON ALL
 PORTIONS OF THE MEANS
 OF EGRESS DURING SUCH HOURS, WHEN APPROVED BY THE
 AUTHORITY HAVING
 JURISDICTION
  
 7.8.1.1* ILLUMINATION OF MEANS OF EGRESS SHALL BE
 PROVIDED IN ACCORDANCE
 WITH SECTION 7.8 FOR EVERY BUILDING AND STRUCTURE WHERE
 REQUIRED IN
 CHAPTERS 11 THROUGH 43. FOR THE PURPOSES OF THIS
 REQUIREMENT, EXIT ACCESS
 SHALL INCLUDE ONLY DESIGNATED STAIRS, AISLES,
 CORRIDORS, RAMPS, ESCALATORS,
 AND PASSAGEWAYS LEADING TO AN EXIT. FOR THE PURPOSES OF
 THIS REQUIREMENT,
 EXIT DISCHARGE SHALL INCLUDE ONLY DESIGNATED STAIRS,
 AISLES, CORRIDORS,
 RAMPS, ESCALATORS, WALKWAYS, AND PASSAGEWAYS LEADING TO
 A PUBLIC WAY
  
 PLEASE PROVIDE FOR THE REQUIRED ILLUMINATION OR PROVIDE
 DETAILS OF THE ALTERNATIVE REQUIREMENT.
  
  
 2A) THERE IS NO INDICATION OF THE PROPOSED OCCUPANCY
 CLASSIFICATION.
  
 IT APPEARS TO BE A COMMERCIAL PARKING GARAGE, WHICH
 SHALL COMPLY WITH NFPA 101 CH 42, STORAGE OCCUPANCY
  
 42.2.10 MARKING OF MEANS OF EGRESS. MEANS OF EGRESS
 SHALL HAVE
 SIGNS IN ACCORDANCE WITH SECTION 7.10.
  
 7.10.1.2 EXITS.
 7.10.1.2.1* EXITS, OTHER THAN MAIN EXTERIOR EXIT DOORS
 THAT OBVIOUSLY
 AND CLEARLY ARE IDENTIFIABLE AS EXITS, SHALL BE MARKED
 BY AN APPROVED
 SIGN THAT IS READILY VISIBLE FROM ANY DIRECTION OF EXIT
 ACCESS
  
 PLEASE PROVIDE AN EXIT SIGN.
  
  
 3) THERE IS NO INDICATION OF THE PROPOSED OCCUPANCY
 CLASSIFICATION.
  
 IT APPEARS TO BE A COMMERCIAL PARKING GARAGE, WHICH
 SHALL COMPLY WITH NFPA 101 CH 42, STORAGE OCCUPANCY
  
 42.2.9 EMERGENCY LIGHTING. EMERGENCY LIGHTING SHALL BE
 PROVIDED IN
 NORMALLY OCCUPIED STORAGE OCCUPANCIES IN ACCORDANCE
 WITH SECTION 7.9,
 EXCEPT FOR SPACES OCCUPIED ONLY DURING DAYLIGHT HOURS
 WITH NATURAL
 ILLUMINATION IN ACCORDANCE WITH 42.2.8.2.
  
 7.9.1.1* EMERGENCY LIGHTING FACILITIES FOR MEANS OF
 EGRESS SHALL BE
 PROVIDED IN ACCORDANCE WITH SECTION 7.9 FOR THE
 FOLLOWING:
 (1) BUILDINGS OR STRUCTURES WHERE REQUIRED IN CHAPTERS
 11 THROUGH 43
 (2) UNDERGROUND AND LIMITED ACCESS STRUCTURES AS
 ADDRESSED IN
 SECTION 11.7
 (3) HIGH-RISE BUILDINGS AS REQUIRED BY OTHER SECTIONS
 OF THIS CODE
 (4) DOORS EQUIPPED WITH DELAYED-EGRESS LOCKS
 (5) STAIR SHAFTS AND VESTIBULES OF SMOKEPROOF
 ENCLOSURES, FOR WHICH
 THE FOLLOWING ALSO APPLY:
 (A) THE STAIR SHAFT AND VESTIBULE SHALL BE PERMITTED TO
 INCLUDE A
 STANDBY GENERATOR THAT IS INSTALLED FOR THE SMOKEPROOF
 ENCLO SURE MECHANICAL VENTILATION EQUIPMENT.
 (B) THE STANDBY GENERATOR SHALL BE PERMITTED TO BE USED
 FOR THE
 STAIR SHAFT AND VESTIBULE EMERGENCY LIGHTING POWER
 SUPPLY.
 (6) NEW SENSOR-RELEASE OF ELECTRICAL LOCKING SYSTEMS IN
 ACCORDANCE
 WITH 7.2.1.6.2
  
 PLEASE PROVIDE THE REQUIRED EMERGENCY LIGHTING
  
  
  
 4) THERE IS NO INDICATION OF THE PROPOSED OCCUPANCY
 CLASSIFICATION.
  
 IT APPEARS TO BE A COMMERCIAL PARKING GARAGE, WHICH
 SHALL COMPLY WITH NFPA 101 CH 42, STORAGE OCCUPANCY
  
 42.2.7 DISCHARGE FROM EXITS. DISCHARGE FROM EXITS SHALL
 BE IN ACCOR DANCE WITH SECTION 7.7
  
 7.7 DISCHARGE FROM EXITS
 7.7.1* EXIT TERMINATION. EXITS SHALL TERMINATE
 DIRECTLY, AT A PUBLIC
 WAY OR AT AN EXTERIOR EXIT DISCHARGE, UNLESS OTHERWISE
 PROVIDED IN 7.7.1.2
 THROUGH 7.7.1.4.
  
 PLEASE PROVIDE DETAILS IN COMPLIANCE.
  
  
 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-12-16 Cont ID  
Sent By aoliver Date 2022-12-16 Time 11:12 Rev Time 0.00
Received By aoliver Date 2022-11-14 Time 07:42 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-12-09 Cont ID  
Sent By rmcphers Date 2022-12-09 Time 16:21 Rev Time 0.00
Received By rmcphers Date 2022-12-09 Time 16:21 Sent To  
Notes
2022-12-09 16:21:59PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-12-14 Cont ID  
Sent By hmoser Date 2022-12-14 Time 10:49 Rev Time 0.00
Received By hmoser Date 2022-12-14 Time 10:49 Sent To  
Notes
2022-12-14 10:52:58NO AIR CONDITIONING PLANS OR ENERGY CALCULATIONS
 SUBMITED
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-12-06 Cont ID  
Sent By rwbrown Date 2022-12-06 Time 05:47 Rev Time 0.00
Received By rwbrown Date 2022-12-06 Time 05:47 Sent To  
Notes
2022-12-06 05:51:271ST PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FPC 403.1.1 - THE TYPE OF OCCUPANCY IS NOT
 LISTED. PLEASE LIST THE OCCUPANCY AND SHOW THE MINIMUM
 PLUMBING FACILITIES REQUIRED BY THE FLORIDA PLUMBING
 CODE.
  
 2. PLEASE INCLUDE WITH YOUR PLANS THE MINIMUM PLAN
 REVIEW CRITERIA AS APPLICABLE:
 2017 WPB AMENDS 107.3.5.1.3 PLUMBING
  1. MINIMUM PLUMBING FACILITIES
  2. FIXTURE REQUIREMENTS
  3. WATER SUPPLY PIPING
  4. SANITARY DRAINAGE
  5. WATER HEATERS
  6. VENTS
  7. ROOF DRAINAGE
  8. BACK FLOW PREVENTION
  9. IRRIGATION
  10. LOCATION OF WATER SUPPLY LINE
  11. GREASE TRAPS
  12. ENVIRONMENTAL REQUIREMENTS
  13. PLUMBING RISER
  14. DESIGN FLOOD ELEVATION
  
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2022-12-09 Cont ID  
Sent By rmcphers Date 2022-12-09 Time 16:19 Rev Time 0.00
Received By rmcphers Date 2022-12-09 Time 16:19 Sent To  
Notes
2022-12-09 16:20:20THIS IS A METAL BUILDING - A ROOFING SYSTEM IS NOT
 REQUIRED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-12-09 Cont ID  
Sent By rmcphers Date 2022-12-09 Time 16:18 Rev Time 0.00
Received By rmcphers Date 2022-12-09 Time 16:18 Sent To  
Notes
2022-12-09 16:19:43SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWING DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE
 READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  

Review Stop Z ZONING
Rev No 1 Status F Date 2022-11-29 Cont ID  
Sent By kdefranc Date 2022-11-29 Time 18:03 Rev Time 0.00
Received By kdefranc Date 2022-11-29 Time 18:02 Sent To  
Notes
2022-11-29 18:02:5511/29/22 ??? FAILED
  
 REVIEW COMMENT TO BE ADDRESSED:
 1. BASED ON THE INFORMATION PROVIDED AND THE CITY???S
 ZONING AND LAND DEVELOPMENT REGULATIONS SUBSECTION
 94-304(A)(1), THE SUBJECT PROPOSAL IS NOT PERMITTED.
  
  
 KEVIE DEFRANC
 SENIOR PLANNER - PLANNING DIVISION
 [email protected]
 561-822-1449
  