| Plan Review Stops For Permit 22100087 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
4 |
Status |
P |
Date |
2023-03-10 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-03-10 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-03-10 |
Time |
12:20 |
Sent To |
|
|
| Notes |
| 2023-03-10 12:20:31 | APPLICATION UPDATED |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
F |
Date |
2023-01-31 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-01-31 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-01-31 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2023-01-31 09:01:49 | PREVIOUS COMMENTS NOT ADDRESSED |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2022-12-16 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-12-16 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-12-16 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2022-12-16 10:56:24 | PREVIOUS COMMENTS NOT ADDRESSED |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2022-10-08 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-10-08 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-10-08 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2022-10-08 09:29:34 | APPLICATION AND PLANS LIST THE ADDRESS AS 2700 BROADWAY | | | HOWEVER BASED ON THE BUILDING LAYOUT I BELIEVE THE | | | CORRECT ADDRESS IS 2708 BROADWAY, ALSO PLEASE LIST THE | | | UNIT ADDRESSES EFFECTED BY THIS PERMIT. ALL THE | | | PREVIOUS UNIT ADDRESSES WERE RETIRED, NEW UNIT | | | ADDRESSES NEED TO BE ASSIGNED. PLEASE CONTACT | | | [email protected] OR CALL 561-805-6659 TO DISCUSS | | | THE ADDRESSING ISSUES. |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
5 |
Status |
P |
Date |
2023-05-24 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-05-24 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-05-24 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2023-05-24 08:36:18 | OK PER D BATTLES |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
4 |
Status |
F |
Date |
2023-05-10 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-05-10 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-05-10 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2023-05-10 11:32:25 | AN ASBESTOS SURVEY IS NOT REQUIRED - - PLEASE PROVIDE A | | | SIGNED ACKNOWLEDGEMENT FROM THE CONTRACTOR, ON | | | LETTERHEAD, STATING THAT THE INSTRUCTIONS ON THE | | | WEBSITE OF ASBESTOS PROGRAM COORDINATOR, FLORIDA | | | DEPARTMENT OF HEALTH PALM BEACH COUNTY WILL BE | | | FOLLOWED, AND THAT NOTIFICATION WILL BE GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
F |
Date |
2023-02-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-01 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-01 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2023-02-01 10:55:14 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2022-12-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-12-19 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-12-19 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2022-12-19 14:55:52 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2022-11-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-11-16 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-11-16 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2022-11-16 13:04:35 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-02-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-01 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-01 |
Time |
10:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-12-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-12-19 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-12-19 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2022-12-19 14:53:24 | ALTERATION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE SHOW THE EXISTING TENANT SEPARATION HOURLY | | | FIRE RATING - FBC 708.1 | | | | | | 2) PLEASE SHOW THE WIND DESIGN DATA USED FOR THE WIND | | | DESIGN - FBC 1603.1.4 | | | | | | 3) THE ADDRESS ON THE DRAWINGS NEEDS TO MATCH THE | | | ADDRESS OF THE BUILDING. | | | | | | 4) PLEASE SHOW THE BUILDING CONSTRUCTION TYPE - FBC | | | 602.1 | | | | | | 5) PLEASE LABEL THE ACCESSIBLE ROOMS - FBC 233.3.4.2 | | | ALTERATIONS TO INDIVIDUAL RESIDENTIAL DWELLING UNITS. | | | IN INDIVIDUAL RESIDENTIAL DWELLING UNITS, WHERE A | | | BATHROOM OR A KITCHEN IS SUBSTANTIALLY ALTERED, AND AT | | | LEAST ONE OTHER ROOM IS ALTERED, THE REQUIREMENTS OF | | | 233.3.1 SHALL APPLY TO THE ALTERED RESIDENTIAL DWELLING | | | UNITS UNTIL THE TOTAL NUMBER OF RESIDENTIAL DWELLING | | | UNITS COMPLIES WITH THE MINIMUM NUMBER REQUIRED BY | | | 233.3.1.1 AND 233.3.1.2. RESIDENTIAL DWELLING UNITS | | | REQUIRED TO COMPLY WITH 233.3.1.1 SHALL BE ON AN | | | ACCESSIBLE ROUTE AS REQUIRED BY 206. | | | | | | 6) ACCESSIBLE RESTROOM = PLEASE SHOW THE SHOWER SEAT | | | DIMENSION DETAILS FBC A 610.3 | | | | | | 7) ACCESSIBLE RESTROOM = PLEASE SHOW THE SHOWER GRAB | | | BAR DIMENSION DETAILS FBC A 609 | | | | | | 8) ACCESSIBLE BATHROOM = PLEASE SHOW ALL SHOWER DETAILS | | | - THRESHOLDS, CONTROLS, GRAB BARS ETC. - DIMENSIONS AND | | | LOCATIONS PER FBC 608 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-11-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-11-16 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-11-16 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2022-11-16 13:28:39 | ALTERATION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE SHOW THE EXISTING TENANT SEPARATION HOURLY | | | FIRE RATING - FBC 708.1 | | | | | | 2) PLEASE SHOW THE WIND DESIGN DATA USED FOR THE WIND | | | DESIGN - FBC 1603.1.4 | | | | | | 3) THE ADDRESS ON THE DRAWINGS NEEDS TO MATCH THE | | | ADDRESS OF THE BUILDING. | | | | | | 4) PLEASE SHOW THE BUILDING CONSTRUCTION TYPE - FBC | | | 602.1 | | | | | | 5) PLEASE LABEL THE ACCESSIBLE ROOMS - FBC 233.3.4.2 | | | ALTERATIONS TO INDIVIDUAL RESIDENTIAL DWELLING UNITS. | | | IN INDIVIDUAL RESIDENTIAL DWELLING UNITS, WHERE A | | | BATHROOM OR A KITCHEN IS SUBSTANTIALLY ALTERED, AND AT | | | LEAST ONE OTHER ROOM IS ALTERED, THE REQUIREMENTS OF | | | 233.3.1 SHALL APPLY TO THE ALTERED RESIDENTIAL DWELLING | | | UNITS UNTIL THE TOTAL NUMBER OF RESIDENTIAL DWELLING | | | UNITS COMPLIES WITH THE MINIMUM NUMBER REQUIRED BY | | | 233.3.1.1 AND 233.3.1.2. RESIDENTIAL DWELLING UNITS | | | REQUIRED TO COMPLY WITH 233.3.1.1 SHALL BE ON AN | | | ACCESSIBLE ROUTE AS REQUIRED BY 206. | | | | | | 6) ACCESSIBLE RESTROOM = PLEASE SHOW THE SHOWER SEAT | | | DIMENSION DETAILS FBC A 610.3 | | | | | | 7) ACCESSIBLE RESTROOM = PLEASE SHOW THE SHOWER GRAB | | | BAR DIMENSION DETAILS FBC A 609 | | | | | | 8) ACCESSIBLE BATHROOM = PLEASE SHOW ALL SHOWER DETAILS | | | - THRESHOLDS, CONTROLS, GRAB BARS ETC. - DIMENSIONS AND | | | LOCATIONS PER FBC 608 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2023-02-15 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-02-15 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-02-15 |
Time |
09:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2023-01-06 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-01-06 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-01-06 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2023-01-06 10:58:39 | PREVIOUS COMMENTS NOT ADDRESSED |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-11-18 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-11-18 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-11-18 |
Time |
08:24 |
Sent To |
|
|
| Notes |
| 2022-11-18 10:29:59 | ELECTRIC REVIEW FAILED | | | 1) PLEASE DETAIL LOCATIONS OF ALL ELECTRIC SERVICE | | | EQUIPMENT AND OUTDOOR AIR CONDITIONING EQUIPMENT ON | | | ELECTRICAL FLOOR PLAN. ENSURE INSTALLATION COMPLIES | | | WITH NEC 110.26 CLEARANCE REQUIREMENTS AND RECEPTACLE | | | LOCATION COMPLIANCE WITH NEC 210.63 AND 210.64 | | | 2) PLEASE PROVIDE A RECEPETACLE AT BATH SINK IN MIDDLE | | | AND ADA BATHROM UNITS AS COMPLY WITH NEC 210.60(B) | | | 3) PLEASE PROVIDE A NOTE STATING INSTALLATION WILL | | | COMPLY WITH NEC 210.8 GFI PROTECTION AND 210.12(B) OR | | | (C) ARC FAULT PROTECTION | | | 4) IT APPEARS THE WRONG PANEL SCHEDULE AND LOAD | | | CALCULATION SHEETS WERE SUBMITTED. PLEASE PROVIDE THE | | | CORRECT SHEETS. FBC 107.2 NEC 215.5 | | | | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-10-12 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-10-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-10-11 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2022-10-12 15:19:25 | FIRE PROVISO: | | | | | | THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE | | | MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS | | | | | | ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING | | | DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP | | | DRAWINGS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
N |
Date |
2022-11-21 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-11-21 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-11-21 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2022-11-21 09:54:51 | SUBJECT BUILDING IS OUTSIDE OF HISTORIC LIMITS ON | | | PARCEL. | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-05-24 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-05-24 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-05-23 |
Time |
17:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-05-10 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-05-10 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-04-27 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-02-15 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-02-15 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-01-30 |
Time |
13:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-01-06 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-01-06 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-12-15 |
Time |
07:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-11-22 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-11-22 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-10-07 |
Time |
10:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2023-05-31 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-05-31 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-05-24 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2023-05-31 12:23:10 | 5/31/23 NO IMPACT FEES DUE. LEM | | 2023-05-24 09:37:08 | EMAILED IMPACT FOR REVIEW-AO |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-11-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-11-16 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-11-16 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2022-11-16 13:36:01 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2023-05-12 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-05-09 |
Time |
05:42 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-05-09 |
Time |
05:42 |
Sent To |
|
|
| Notes |
| 2023-05-09 05:42:38 | APPROVED ME | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-07 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-07 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2023-02-07 10:21:37 | 3RD REVIEW FMC | | | PERMIT: 22100087 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) IS THIS AN EXISTING I-2 OCCUPANCY? IF SO THE | | | MECHANICAL DESIGN SHALL MEET THE REQUIREMENTS OF ASHRAE | | | 170-2017. FMC 407 | | | | | | 2) IT IS UNCLEAR TO THIS REVIEWER AS TO WHEREIN THE | | | BUILDING THIS MECHANICAL WORK WILL BE COMPLETED. LABEL | | | THE ROOMS ON THE MECHANICAL SHEET TO MATCH THE ROOM THE | | | WORK IS TO BE COMPLETED FROM THE A-202 DRAWING. | | | | | | 3) IS THIS A NEW ADDITION? IS IT A MECHANICAL CHANGE | | | OUT? IS IT CREATING NEW ROOMS WITHIN AN EXISTING | | | FOOTPRINT? PLEASE HELP ME TO UNDERSTAND THE SCOPE OF | | | THIS PROJECT. | | | | | | 4) SHEET M-1.0: THE AHU IS SUPPLING AIR TO THE NEXT | | | ROOM FROM WHERE THE AHU IS LOCATED. SHOW THE RETURN AIR | | | PATH FROM THIS ROOM BACK TO THE AHU IN THE OTHER ROOM. | | | FMC 601.6 | | | | | | 5) THE AHU MUST MEET THE NEW FEDERAL GUIDELINES FOR THE | | | SEER2 RATINGS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-12-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-12-30 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-12-30 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2022-12-30 11:18:17 | | | | | | | 1ST REVIEW FMC | | | PERMIT: 22100087 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 2ND ATTEMPT TO GET A COMPLETE MECHANICAL DESIGN FOR | | | THIS CHANGE OF USE. | | | | | | 1) PLEASE PROVIDE A COMPLETE MECHANICAL DESIGN FOR THIS | | | CHANGE OF USE FROM AN R-2 TO R-4. THIS SHOULD INCLUDE | | | THE REQUIREMENTS IN FMC 403.3.2 FOR R-4 OCCUPANCIES AND | | | HEATING LOADS REQUIRED BY FMC 312 AND PROVIDE THE | | | ENERGY REQUIREMENTS FROM FEC C403. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-11-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-11-10 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-11-10 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2022-11-10 10:10:20 | 1ST REVIEW FMC | | | PERMIT: 22100087 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE A COMPLETE MECHANICAL DESIGN FOR THIS | | | CHANGE OF USE FROM AN R-2 TO R-4. THIS SHOULD INCLUDE | | | THE REQUIREMENTS IN FMC 403.3.2 FOR R-4 OCCUPANCIES AND | | | HEATING LOADS REQUIRED BY FMC 312 AND PROVIDE THE | | | ENERGY REQUIREMENTS FROM FEC C403. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-12-16 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-12-16 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-11-02 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-11-02 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-11-02 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2022-11-02 10:22:16 | 1ST PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2017 WPB AMENDS 107.3.5.1.3 - PLEASE SUBMIT THE | | | PLUMBING PAGES AS REQUIRED. INCLUDE ISOMETRICS FOR THE | | | NEW CONNECTION FOR BOTH WATER AND DRAIN, WASTE, VENTS, | | | HOT WATER DETAILS, FIXTURE SCHEDULES, ETC. | | | | | | A FULL PLUMBING REVIEW WAS NOT COMPLETED DUE TO LACK OF | | | INFORMATION. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2023-05-09 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-05-09 |
Time |
05:42 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-05-09 |
Time |
05:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-02-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-01 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-01 |
Time |
10:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-12-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-12-19 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-12-19 |
Time |
14:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-11-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-11-16 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-11-16 |
Time |
13:38 |
Sent To |
|
|
| Notes |
|
|