Plan Review Details - Permit 22100058
Plan Review Stops For Permit 22100058
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2023-07-20 Cont ID  
Sent By rmcdouga Date 2023-07-20 Time 08:41 Rev Time 0.00
Received By rmcdouga Date 2023-07-20 Time 08:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-04-20 Cont ID  
Sent By rmcdouga Date 2023-04-20 Time 15:27 Rev Time 0.00
Received By rmcdouga Date 2023-04-20 Time 15:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2022-11-18 Cont ID  
Sent By rmcdouga Date 2022-11-18 Time 07:58 Rev Time 0.00
Received By rmcdouga Date 2022-11-18 Time 06:15 Sent To  
Notes
2022-11-18 07:59:52ADDRESS COMMENTS FROM OTHER REVIEWERS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-04-21 Cont ID  
Sent By rperdomo Date 2023-04-21 Time 10:27 Rev Time 0.00
Received By rperdomo Date 2023-04-21 Time 10:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-11-02 Cont ID  
Sent By rperdomo Date 2022-11-02 Time 14:33 Rev Time 0.00
Received By rperdomo Date 2022-11-01 Time 16:36 Sent To  
Notes
2022-11-02 14:32:44FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 - FOLLOW REQUIREMENT OF NEC 2017 ARTICLE 680.40 PART IV
 SPAS AND HOT TUBS.
 - ONE LINE DIAGRAM SHOWINGS BONDING AND EQUIPMENT
 BONDING, AND EQUIPOTENTIAL BONDING.
  
 RUBEN PEREZ PERDOMO
 ELECTRICAL PLANS EXAMINER
 561-805-6738
 [email protected]
  
  
  

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2023-07-05 Cont ID  
Sent By ccole Date 2023-07-05 Time 17:39 Rev Time 0.00
Received By ccole Date 2023-07-05 Time 15:15 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2023-04-19 Cont ID  
Sent By ccole Date 2023-04-19 Time 09:24 Rev Time 0.00
Received By ccole Date 2023-04-18 Time 13:44 Sent To  
Notes
2023-04-19 09:25:201ST REVIEW FBC-2020 FUEL GAS
 PERMIT- 22100058
 4/19/23
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. PLEASE REVIEW THE COMMENTS
 AND NOTE GAS CAN BE SUBMITTED AS A REVISION TO THE
 MASTER PLAN UNDER PERMIT 18100540. IF THIS OPTION IS
 CHOSEN I WILL PLACE AN "N" RESULT (NO REVIEW) FOR GAS
 AND PERFORM THE REVIEW UNDER THE REVISION SUBMITTAL.
  
 FAILED COMMENTS FROM THE 1ST REVIEW ARE LISTED BELOW
 WITH ADDITIONAL NOTES.
  
 1) FAILED. SHEETS P.700: THE RISER BRANCH THAT
 CORRELATES TO KEYNOTE 1 DOES NOT APPEAR TO BE SHOWN ON
 THE DRAWING. PLEASE PROVIDE A COMPLETE GAS RISER
 DRAWING THAT INCLUDES ALL NEW AND EXISTING GAS PIPING
 INVOLVED WITH SUPPLYING THE GAS HEATER AND OTHER
 APPLIANCES- SECTIONS 401.3 & 401.4 FBC FG. REFER TO FBC
 CHAPTER 4 FUEL FBC- THE RISER SHALL INDICATE:
 A) DELIVERY PRESSURE AT THE METER.
 B) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE AND
 EQUIPMENT BTU LOADS.
 C) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 D) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 E) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE
 UNIONS.
 F) OUTLET PRESSURES AT REGULATORS.
 G) LOCATIONS AND TYPES OF PIPE SLEEVES.
 H) PIPE SIZING TABLES.
  
 THE RISER IS INCOMPLETE BECAUSE IT DOES NOT INCLUDE THE
 LOW PRESSURE PIPING SYSTEM FROM THE REGULATORS TO THE
 POOL HEATERS. A COMPLETE RISER PER COMMENT #1 ABOVE IS
 REQUIRED.
  
 5) FAILED. P.509: SHOW THE GAS VENT PIPING RUN AND
 TERMINATION LOCATION FROM THE EQUIPMENT ROOM BY
 GRIDLINES 10 & K- SEC. 410.3 FBC FG.
  
 THE DESIGN PROFESSIONAL'S NARRATIVE REFERENCES SHEET
 P.105C WHICH WAS NOT UPLOADED FOR REVIEW.
  
 6) FAILED. P.509: PLEASE SUBMIT SHEET P.804 THAT
 CONTAINS THE GAS MONITORING AND DETECTING DETAILS
 CALLED OUT ON THE PLAN- SEC. 107.2.1 WPB.
  
 THE DESIGN PROFESSIONAL'S NARRATIVE REFERENCES SHEET
 P.804 WHICH WAS NOT UPLOADED FOR REVIEW.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-11-16 Cont ID  
Sent By ccole Date 2022-11-16 Time 15:39 Rev Time 0.00
Received By ccole Date 2022-11-16 Time 13:54 Sent To  
Notes
2022-11-16 16:04:571ST REVIEW FBC-2020 FUEL GAS
 PERMIT- 22100058
 11/16/22
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. THE PERMIT APPLICATION IS
 FOR THE INDOOR SPA WHICH HAS A GAS-FIRED POOL HEATER,
 HOWEVER SINCE SHEET P.509 & P.700 SHOWS MULTIPLE POOL
 HEATERS FOR THE OTHER POOL AND SPAS THE APPLICANTS
 SHOULD CONSIDER SUBMITTING A SEPARATE PERMIT
 APPLICATION FOR GAS THAT INCLUDES ALL THE GAS WORK
 RELATING TO THE POOLS AND SPAS. IF A SEPARATE PERMIT IS
 CHOSEN I WILL PLACE AN "N" RESULT (NO REVIEW) FOR GAS
 AND PERFORM THE REVIEW UNDER THE SEPARATE PERMIT.
 PLEASE REVIEW THE COMMENTS AND CONTACT ME IF YOU HAVE
 QUESTIONS..
  
 1) SHEETS P.700: THE RISER BRANCH THAT CORRELATES TO
 KEYNOTE 1 DOES NOT APPEAR TO BE SHOWN ON THE DRAWING.
 PLEASE PROVIDE A COMPLETE GAS RISER DRAWING THAT
 INCLUDES ALL NEW AND EXISTING GAS PIPING INVOLVED WITH
 SUPPLYING THE GAS HEATER AND OTHER APPLIANCES- SECTIONS
 401.3 & 401.4 FBC FG. REFER TO FBC CHAPTER 4 FUEL FBC-
 THE RISER SHALL INDICATE:
 A) DELIVERY PRESSURE AT THE METER.
 B) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE AND
 EQUIPMENT BTU LOADS.
 C) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 D) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 E) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE
 UNIONS.
 F) OUTLET PRESSURES AT REGULATORS.
 G) LOCATIONS AND TYPES OF PIPE SLEEVES.
 H) PIPE SIZING TABLES.
  
 2) SP.420, P.509, P.700: SUBMIT MANUFACTURER' S
 SPECIFICATIONS FOR THE POOL HEATER- SEC.617.1 FBC FG.
  
 3) M.205C: PLEASE TAG EACH DUCT SYSTEM WITH THE
 CORRESPONDING POOL OR SPA HEATER TO HELP EXPEDITE THE
 REVIEW- SEC. 107.2.1 WPB. PROVIDE AN ENLARGED
 DIMENSIONED INTAKE AND EXHAUST DUCT DIAGRAM THAT SHOWS
 THE LENGTHS OF THE DUCT RUNS AND TERMINATION LOCATIONS
 WITH CLEARANCES- SEC. 617.1, 503.2.3 & 503.8 FGB FG. IF
 MULTIPLE FLOORS ARE INVOLVED SHOW THE FLOOR LEVLS IN
 THE DIAGRAM.
  
 A) INDICATE HOW DUCTS WERE SIZED SUBMIT AND SUBMIT
 MANUFACTURER'S SPECIFICATION FOR ALL COMPONENTS OF THE
 SYSTEM INCLUDING THE TERMINATION CAPS.
  
 B) SHOW THE TERMINATION LOCATION CLEARANCES TO OTHER
 EXHAUST OUTLETS AND AIR INTAKE OPENINGS.
  
 4) P.509: PLEASE INDICATE WHICH FLOOR LEVELS THE
 EQUIPMENT ROOMS ARE ON- SEC. 107.2.1 WPB.
  
 5) P.509: SHOW THE GAS VENT PIPING RUN AND TERMINATION
 LOCATION FROM THE EQUIPMENT ROOM BY GRIDLINES 10 & K-
 SEC. 410.3 FBC FG.
  
 6) P.509: PLEASE SUBMIT SHEET P.804 THAT CONTAINS THE
 GAS MONITORING AND DETECTING DETAILS CALLED OUT ON THE
 PLAN- SEC. 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-07-20 Cont ID  
Sent By hmoser Date 2023-07-20 Time 09:46 Rev Time 0.00
Received By hmoser Date 2023-07-03 Time 10:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-04-25 Cont ID  
Sent By medwards Date 2023-04-25 Time 13:16 Rev Time 0.00
Received By medwards Date 2023-04-14 Time 09:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-11-22 Cont ID  
Sent By lmarchan Date 2022-11-22 Time 13:23 Rev Time 0.00
Received By lmarchan Date 2022-10-28 Time 12:51 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2023-07-20 Cont ID  
Sent By hmoser Date 2023-07-20 Time 09:46 Rev Time 0.00
Received By hmoser Date 2023-07-20 Time 09:46 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2023-04-25 Cont ID  
Sent By medwards Date 2023-04-25 Time 13:11 Rev Time 0.00
Received By medwards Date 2023-04-25 Time 13:11 Sent To  
Notes
2023-04-25 13:12:16PROVIDE DIGITALLY SIGNED MECHANICAL DRAWINGS FOR THIS
 POOL. FS471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-11-21 Cont ID  
Sent By medwards Date 2022-11-21 Time 07:52 Rev Time 0.00
Received By medwards Date 2022-11-21 Time 07:51 Sent To  
Notes
2022-11-21 07:52:131ST REVIEW FMC
 PERMIT: 22100058
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M.205C: PROVIDE A DRAWING THAT SHOWS THE
 LOCATION OF EF-62, IS THIS EXHAUST TERMINATION ON THE
 ROOF? PLEASE PROVIDE THE SPECS FOR EF-62. PLEASE SHOW
 WHERE THE MAKEUP AIR IS BEING INTRODUCED INTO THE POOL
 PUMP ROOM. FBC 107.3.5
  
 2) SHEET M.207A: PROVIDE THE SPECS FOR EF-48. FBC
 107.3.5
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2023-07-05 Cont ID  
Sent By ccole Date 2023-07-05 Time 17:38 Rev Time 0.00
Received By ccole Date 2023-07-05 Time 15:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2023-04-19 Cont ID  
Sent By ccole Date 2023-04-19 Time 08:56 Rev Time 0.00
Received By ccole Date 2023-04-18 Time 13:44 Sent To  
Notes
2023-04-19 09:12:302ND REVIEW FBC-2020 PLUMBING
 PERMIT- 22100058
 4/19/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC RES- FLORIDA BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED 1ST REVIEW COMMENTS
 #1 & #11 ARE LISTED BELOW WITH ADDITIONAL NOTES.
  
 1) FAILED. SHEET SP.003 & SP.620: REFER TO SEC.
 454.1.1.1 FBC B AND PROVIDE THE FOLLOWING INFORMATION
 ON THE PLAN.
 A) THE POOL IS FOR USE BY TRANSIENT OR NON-TRANSIENT
 OCCUPANTS OF THE FACILITY.
 B) CLARIFY HOW THE BATHING LOAD WAS CALCULATED.
  
 SHEETS SP.001 & SP.002: PLEASE CORRECT THE CALCULATIONS
 SO THEY CLEARLY INDICATE (TRANSIENT UNITS- 5 BATHERS
 PER TRANSIENT UNIT), AND (NON-TRANSIENT UNITS- 7
 BATHERS PER TRANSIENT UNIT)- SEC. 454.1.1.1 FBC B.
 CORRECT THE MIAMI LOCATION TO WEST PALM BEACH.
  
 11) FAILED. P.509: PLEASE REMOVE THE NOTE REQUIRING
 SEPARATE PERMITS FOR THE RPZ BACKFLOW PREVENTERS AND
 PROVIDE EQUIPMENT SCHEDULES ON THE PLAN- SEC. 608.3 &
 608.16 FBC P.
  
 SEPARATE PERMITS ARE NOT REQUIRED FOR ISOLATION
 BACKFLOW DEVICES INSTALLED ON SUPPLY LINES DOWNSTREAM
 OF THE MAIN POTABLE WATER SERVICE BACKFLOW PREVENTER.
 PLEASE PROVIDE THE REQUESTED COMPLIANCE INFORMATION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-11-16 Cont ID  
Sent By ccole Date 2022-11-16 Time 15:16 Rev Time 0.00
Received By ccole Date 2022-11-16 Time 10:50 Sent To  
Notes
2022-11-16 15:16:431ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22100058
 11/16/22
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC RES- FLORIDA BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. BASED ON THE PERMIT
 APPLICATION PLEASE NOTE THE FOLLOWING COMMENTS ARE FOR
 THE INDOOR SPA ONLY WITH THE EXCEPTION OF COMMENT #2
 WHICH INCLUDES THE SPA.
  
 1) SHEET SP.003 & SP.620: REFER TO SEC. 454.1.1.1 FBC B
 AND PROVIDE THE FOLLOWING INFORMATION ON THE PLAN.
 A) THE POOL IS FOR USE BY TRANSIENT OR NON-TRANSIENT
 OCCUPANTS OF THE FACILITY.
 B) CLARIFY HOW THE BATHING LOAD WAS CALCULATED.
  
 2) SHEETS SP.003 & A1.107: PROVIDE PLUMBING FIXTURE
 CALCULATIONS FOR THE POOL AND SPA IN ACCORDANCE WITH
 TABLE 403.6 FBC P, AND TABLE 454.1.6.1, AND SEC.
 454.1.8.1 FBC B. THERE ARE MULTIPLE BATHROOMS ON THE
 FLOOR, BUT NONE DESIGNATED AS POOL BATHROOMS. PLEASE
 SEE THE EXCEPTION UNDER SEC. 454.1.6.1.1. AND IF
 APPLICABLE THEN THE FIXTURE REQUIREMENT FOR THE
 BUILDING SHALL BE DETERMINED AND IF IT EXCEEDS THE
 REQUIREMENT IN TABLE 454.1.6.1 THEN THE BUILDING
 REQUIREMENT SHALL REGULATE THE FIXTURE COUNT, OTHERWISE
 THE FIXTURE COUNT SHALL BE BASED ON THE REQUIREMENT FOR
 THE POOL. UNDER NO CIRCUMSTANCES SHALL THE FIXTURE
 COUNTS BE CUMULATIVE.
 PLEASE ALSO SHOW COMPLIANCE WITH THE FOLLOWING CODE
 SECTIONS-
 A) SEC. 454.1.6.1.1: CONFIRM WITH DETAILS AND/OR NOTES
 THAT FIXTURE COUNT IS DEEMED TO BE ADEQUATE FOR THE
 POOL AND SPA AND POOL AND SPA DECK THAT IS UP TO THREE
 TIMES THE AREA OF THE POOL SURFACE.
 B) SECS. 454.1.6.1.3: CONFIRM WITH DETAILS AND/OR NOTES
 THAT EACH BATHROOM CONTAINS A FLOOR DRAIN.
  
 3) SP.610 DETAIL 7: SHOW THE WALL INLET LOCATION IS A
 MINIMUM OF 12-INCHES BELOW THE NORMAL OPERATING WATER
 LEVEL- SECS. 454.1.8.1 & 454.1.6.5.9 FBC B.
  
 4) SP.750: PLEASE PROVIDE TDH CALCULATIONS FOR PUMP
 SIZING- SEC. 454.1.6.5.4 FBC B.
  
 5) SP.620: PROVIDE A BACKFLOW PREVENTER FOR THE WATER
 SUPPLY LINE TO THE COLLECTOR TANK, AND INCLUDE AN
 EQUIPMENT SCHEDULE- SEC. 608.3 FBC P & SEC. 454.1.6.3
 FBC B.
  
 6) SP.620: PLEASE SUBMIT MANUFACTURER'S SPECIFICATIONS
 FOR THE MAIN DRAIN GRATE AND SUMP SHOWING COMPLIANCE
 WITH SEC. 454.1.6.5.10.2 AND ANSI/APSP 16.
  
 7) SP.620: THE PIPING PLANS SHOW POOL WASTEWATER
 DRAINING INTO THE SANITARY SYSTEM WHICH IS PROHIBITED-
 SEC. 90-126 (5) WPB CODE OF ORDINANCES. THE DRAWINGS
 ALSO SHOW THE COLLECTOR TANK OVERFLOW DRAINING INTO THE
 STORM. PLEASE REVIEW THE FOLLOWING INFORMATION AND
 REVISE THE PLAN ACCORDINGLY.
 SWIMMING POOL WATER SHALL NOT BE DISCHARGED TO SANITARY
 SEWER WITHOUT PRIOR APPROVAL FROM THE PUBLIC UTILITIES
 DEPARTMENT.
 SWIMMING POOL WATER MAY BE DISCHARGED TO THE CITY
 STORMWATER SEWER ONLY IF THE WATER IS DECHLORINATED
 ACCORDING TO SECTION 90-205(1) OF THE CITY OF WEST PALM
 BEACH CODE OF ORDINANCES. SUBMIT THE MANUFACTURER'S
 SPECIFICATION FOR THE DECHLORINATION SYSTEM FOR REVIEW
 AND STAMPING BEFORE THE INSPECTION. AT THE TIME OF POOL
 WATER DISCHARGE, THE FOLLOWING WILL BE REQUIRED:
 * THE RECEIVING INLET MUST BE PROTECTED (FILTER CLOTH
 TO KEEP EXCESS SEDIMENTS FROM ROADWAY WASHING INTO THE
 INLET).
 * NO DISCHARGE HOSE CAN BE DIRECTLY INSERTED INTO THE
 INLET TO DISCHARGE EFFLUENT.
 * WHENEVER POSSIBLE, DISCHARGE EFFLUENT SHALL BE
 ALLOWED TO FILTER THROUGH GRASS AREA ON THE POOL OWNERS
 PROPERTY BEFORE DISCHARGING ON CITY PROPERTY.
 * DISCHARGE SHALL NOT FLOOD STREETS OR NEIGHBORING
 PROPERTY.
 * FOR TECHNICAL QUESTIONS, CONTACT O&M SUPERINTENDENT
 STEPHON HARRIS AT [email protected] OR 561-822-2168.
 * FOR STORMWATER DISCHARGE COMPLIANCE QUESTIONS, PLEASE
 CONTACT CHRIS JACKSON, ENVIRONMENTAL COMPLIANCE
 SPECIALIST III, PUBLIC UTILITIES DEPARTMENT, (561)
 822-2062 OR [email protected].
  
 8) SP.620, SP.509: THE EMERGENCY SHOWER AND EYEWASH
 STATIONS SHALL CONFORM TO ISEA Z358.1. SUBMIT
 MANUFACTURER' S SPECIFICATIONS TO VERIFY COMPLIANCE.
 A) PLEASE NOTE IF HOT WATER IS SUPPLIED TO THE UNIT IT,
 THE TEMPERATURE OF THE WATER SUPPLY SHALL ONLY BE
 CONTROLLED BY A TEMPERATURE ACTUATED MIXING VALVE
 COMPLYING WITH ASSE 1071- SEC. 411.3 FBC P. PLEASE NOTE
 THE SPECS MAY BE A DEFERRED SUBMITTAL IN COMPLIANCE
 WITH SEC. 107.3.4.1 WPB.
  
 9) SP.610: SUBMIT MANUFACTURER' S SPECIFICATIONS FOR
 THE POOL LIFT SHOWING COMPLIANCE WITH SECS. 1009.1-
 1009.2.9 FBC ACC. PLEASE NOTE THE SPECS MAY BE A
 DEFERRED SUBMITTAL IN COMPLIANCE WITH SEC. 107.3.4.1
 WPB.
  
 10) SP.620: PROVIDE A POOL EQUIPMENT SUBMITTAL PACKAGE
 THAT INCLUDES BUT IS NOT LIMITED TO THE ITEMS LISTED IN
 THE SCHEDULE UNDER THE PERIMETER OVERFLOW AND
 RECIRCULATION SYSTEM, AND THE FILTRATION EQUIPMENT-
 SEC. 107.2.1 WPB. PLEASE NOTE ALL SUBMITTALS CAN BE
 DEFERRED AND PLACED ON SITE AT TIME OF INSPECTION- SEC.
 10.3.4.1 WPB.
  
 11) P.509: PLEASE REMOVE THE NOTE REQUIRING SEPARATE
 PERMITS FOR THE RPZ BACKFLOW PREVENTERS AND PROVIDE
 EQUIPMENT SCHEDULES ON THE PLAN- SEC. 608.3 & 608.16
 FBC P. SEPARATE PERMITS ARE NOT REQUIRED FOR ISOLATION
 BACKFLOW DEVICES INSTALLED ON SUPPLY LINES DOWNSTREAM
 OF THE MAIN POTABLE WATER SERVICE BACKFLOW PREVENTER.
  
 12) SP.003: PROVIDE SPA SIGNAGE DETAILS- SECS.
 454.1.2.3.5, 454.1.8.13, 454.1.8.14, & 454.1.8.15 FBC
 B.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-07-05 Cont ID  
Sent By ccole Date 2023-07-05 Time 17:39 Rev Time 0.00
Received By ccole Date 2023-07-05 Time 17:39 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2023-04-20 Cont ID  
Sent By rmcdouga Date 2023-04-20 Time 16:29 Rev Time 0.00
Received By rmcdouga Date 2023-04-20 Time 16:29 Sent To  
Notes
2023-04-20 16:21:40BUILDING SHEETS SP.001, SP.002, SP.600, 6.51, 6.52 AND
 6.53 ARE NOT DIGITALLY SIGNED. OTHER SHEETS ARE ALSO
 NOT DIGITALLY SIGNED OR ARE SELF-CERTIFIED BY THE
 ENGINEER (NOT ALLOWED BY THE FLORIDA BOARD OF
 PROFESSIONAL ENGINEERS). ALL PLANS THAT ARE SUBMITTED
 FOR PERMIT THAT ARE FROM A FLORIDA LICENSED DESIGN
 PROFESSIONAL ARE REQUIRED TO BE SIGNED AND SEALED.
 ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE
 THE ARCHITECT OR ENGINEER'S DIGITAL SIGNATURE ON THEM.
 FS 481 & FAC 61G1 OR FS 471 & FAC 61G15

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-11-18 Cont ID  
Sent By rmcdouga Date 2022-11-18 Time 07:29 Rev Time 0.00
Received By rmcdouga Date 2022-11-18 Time 06:15 Sent To  
Notes
2022-11-18 07:48:02SOME OF THE PLANS ARE NOT DIGITALLY SIGNED BY THE
 ENGINEER AND SOME HAVE BEEN SELF-CERTIFIED BY THE
 ENGINEER THAT DIGITALLY SIGNED THEM. THE FLORIDA BOARD
 OF PROFESSIONAL ENGINEERS REQUIRES ENGINEERS TO USE AN
 APPROVED THIRD PARTY CERTIFICATION AGENCY.
 ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE
 THE ARCHITECT OR ENGINEER'S DIGITAL SIGNATURE ON THEM.
 FS 481 & FAC 61G1 OR FS 471 & FAC 61G15

Review Stop Z ZONING
Rev No 2 Status P Date 2023-04-25 Cont ID  
Sent By ckimmerl Date 2023-04-25 Time 11:51 Rev Time 0.00
Received By ckimmerl Date 2023-04-25 Time 11:51 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-11-21 Cont ID  
Sent By ckimmber Date 2022-11-21 Time 15:26 Rev Time 0.00
Received By ckimmerl Date 2022-11-21 Time 15:26 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy