| Plan Review Stops For Permit 22091262 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2023-05-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-22 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-22 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-05-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-05 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-05 |
Time |
12:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-12-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-12-22 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-12-22 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2022-12-22 11:01:13 | 2ND BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: CERTIFICATION OF PERGOLA UNDER CHAPT. 553, PART | | | 1 F.S. HAS NOT BEEN PROVIDED. | | | SEE COMMENTS UNDER SIGNATURE REVIEW. | | | | | | 1. PROVIDE DEMENSIONS OF PERGOLA TO PROPERTY LINES. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | 2. PROVIDE A STRUCTURAL DETAIL OF FOOTINGS/FOUNDATION. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | 3. SPECIFY CONCRETE ANCHORS AT POST BASE TO FOUNDATION | | | CONNECTION. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-11-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-04 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-11-04 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2022-11-04 13:25:24 | 1ST BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: EVERY STRUCTURE SUBJECT TO WIND LOADS SHALL BE | | | DESIGNED PER FBC CHPT 16, FBC RES CHPT 3 SECTION R301 | | | OR ASCE 7. | | | | | | 1.PROVIDE A COPY OF THE MOST RECENT BOUNDARY LINE | | | SURVEY. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2.PROVIDE THE MANUFACTURER???S CERTIFICATION UNDER THE | | | MANUFACTURED BUILDING PROGRAM, AS PROVIDED FOR UNDER | | | CHAPTER 553, PART 1, FLORIDA STATUTES. (F.S.) | | | INCLUDE A COPY OF THE CURRENT FLORIDA PRODUCT APPROVAL. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | OPTION TO #2 ABOVE: | | | | | | 3. PROVIDE THE FOLLOWING BUILDING PLANS AND DETAILS | | | 3A) FOUNDATION PROVIDE POST BASE CONNECTOR | | | 3B) WALL PROVIDE POSTL TO TRUSS CONNECTOR. | | | 3C) ROOF PROVIDE TRELLIS TO TRUSS CONNECTOR. | | | 3D) PROVIDE A FASTENER SCHEDULE OR SPECIFY WHAT | | | FASTENERS ARE USED FOR EACH CONNECTOR. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-05-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-22 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-09 |
Time |
08:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-05-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-05 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-04-20 |
Time |
07:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-12-27 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2022-12-27 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2022-12-02 |
Time |
08:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-11-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-04 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-03 |
Time |
06:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2023-05-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-22 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-22 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2023-05-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-05 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-05 |
Time |
12:33 |
Sent To |
|
|
| Notes |
| 2023-05-05 12:41:18 | 3RD SIGNATURE REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: ALL PLAN PAGES: DIGITAL SIGNATURES APPEAR TO BE | | | COPIES | | | | | | 1.DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A | | | VALID DIGITAL SIGNATURE. | | | A SCAN OF A WET SEAL AND SIGNATURE OR DIGITAL SIGNATURE | | | IS NOT CONSIDERED A VALID DIGITAL SIGNATURE. | | | | | | 2.SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE PER F.S. | | | 668.003 (3); | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5). | | | F.S. 471; F.A.C. 61G15-23.005 (ENGINEERS) | | | F.S. 481; F.A.C. 61G1-16.005 (ARCHITECTS) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-12-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-12-22 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-12-22 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2022-12-22 10:56:03 | 2ND SIGNATURE REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: CERTIFICATION OF PERGOLA UNDER CHAPT. 553, PART | | | 1 F.S. HAS NOT BEEN PROVIDED. | | | | | | | | | 1.THE OWNER/BUILDER, CONTRACTOR OR DESIGNER OF RECORD | | | SHALL PROVIDE THEIR PRINTED NAME AND SIGNATURE ON PLAN | | | SHEETS UNDER THEIR AUTHORITY. | | | 2017 WPB AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1, SECTION 107.2.1. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | | 481, F.S. & 61G1. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2022-11-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-04 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-11-04 |
Time |
12:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-12-27 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2022-12-27 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2022-12-27 |
Time |
12:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-10-07 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-10-07 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-10-07 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|