Plan Review Details - Permit 22091252
Plan Review Stops For Permit 22091252
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2022-11-28 Cont ID  
Sent By jwitmer Date 2022-11-28 Time 14:40 Rev Time 0.00
Received By jwitmer Date 2022-11-15 Time 14:39 Sent To  
Notes
2022-11-15 14:40:33UPLOADED E-MAIL PDF FOR ASBESTOS. PASSED, J WITMER
 11/28/22

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-12-20 Cont ID  
Sent By jwitmer Date 2022-12-20 Time 11:34 Rev Time 0.00
Received By jwitmer Date 2022-12-20 Time 11:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2022-11-28 Cont ID  
Sent By jwitmer Date 2022-11-28 Time 15:02 Rev Time 0.00
Received By jwitmer Date 2022-11-15 Time 14:39 Sent To  
Notes
2022-11-15 15:02:3011/21/22 MIKE ODUM UPLADED REQUIRED SOUND TESTING
 REPORTS PLUS FLAME SPREAD REPORT. PASSED J. WITMER
 11/28/22.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-12-14 Cont ID  
Sent By jleahy Date 2022-12-14 Time 15:23 Rev Time 0.00
Received By jleahy Date 2022-12-14 Time 15:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-11-01 Cont ID  
Sent By jleahy Date 2022-11-01 Time 11:04 Rev Time 0.00
Received By jleahy Date 2022-11-01 Time 10:46 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-12-15 Cont ID  
Sent By pleduc Date 2022-12-15 Time   Rev Time 0.00
Received By pleduc Date 2022-12-15 Time 15:27 Sent To  
Notes
2022-12-15 15:27:27FIRE PROVISO:
  
 PROTECT FIRE SPRINKLERS AND FIRE ALARM DEVICES AND
 EQUIPMENT.
  
 DO NOT PAINT OVER SPRINKLER HEADS AND/OR FIRE ALARM
 DEVICES/EQUIPMENT.
  
  
 THE FS AND FA SYSTEMS SHALL BE MAINTAINED THROUGHOUT
 DEMO AND CONSTRUCTION.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-10-13 Cont ID  
Sent By pleduc Date 2022-10-13 Time   Rev Time 0.00
Received By pleduc Date 2022-10-13 Time 11:29 Sent To  
Notes
2022-10-13 11:30:01FIRE PROVISO:
  
 PROTECT FIRE SPRINKLERS AND FIRE ALARM DEVICES AND
 EQUIPMENT.
  
 DO NOT PAINT OVER SPRINKLER HEADS AND/OR FIRE ALARM
 DEVICES/EQUIPMENT.
  
  
 THE FS AND FA SYSTEMS SHALL BE MAINTAINED THROUGHOUT
 DEMO AND CONSTRUCTION.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-12-20 Cont ID  
Sent By lmarchan Date 2022-12-20 Time 13:12 Rev Time 0.00
Received By lmarchan Date 2022-12-13 Time 15:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-11-15 Cont ID  
Sent By jwitmer Date 2022-11-15 Time 15:03 Rev Time 0.00
Received By jwitmer Date 2022-10-12 Time 12:13 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2022-11-15 Cont ID  
Sent By jwitmer Date 2022-11-15 Time 14:40 Rev Time 0.00
Received By jwitmer Date 2022-11-15 Time 14:39 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2022-11-02 Cont ID  
Sent By medwards Date 2022-11-02 Time 05:36 Rev Time 0.00
Received By medwards Date 2022-11-02 Time 05:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-12-14 Cont ID  
Sent By rwbrown Date 2022-12-14 Time 13:21 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-10-18 Cont ID  
Sent By rwbrown Date 2022-10-18 Time 13:58 Rev Time 0.00
Received By rwbrown Date 2022-10-18 Time 13:58 Sent To  
Notes
2022-10-18 14:01:241ST PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FPC 918.3.1 - AIR ADMITTANCE VALVES CANNOT BE
 USED IF MORE THAN 4 BRANCH INTERVALS FROM THE TOP OF
 THE STACK, UNLESS PROVIDED WITH A RELIEF VENT IN
 ACCORDANCE WITH THIS SECTION.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-12-13 Cont ID  
Sent By rmcdouga Date 2022-12-13 Time 15:06 Rev Time 0.00
Received By rmcdouga Date 2022-12-13 Time 15:06 Sent To  
Notes
2022-12-13 15:07:51SIGNED AND SEALED PLAN SENT TO STORAGE.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-10-12 Cont ID  
Sent By jleahy Date 2022-10-12 Time 16:18 Rev Time 0.00
Received By jleahy Date 2022-10-12 Time 16:17 Sent To  
Notes
***NONE***