Plan Review Details - Permit 22091180
Plan Review Stops For Permit 22091180
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-10-29 Cont ID  
Sent By cthroop Date 2022-10-29 Time 10:42 Rev Time 0.00
Received By cthroop Date 2022-10-29 Time 10:11 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-10-22 Cont ID  
Sent By cthroop Date 2022-10-22 Time 08:34 Rev Time 0.00
Received By cthroop Date 2022-10-22 Time 08:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-10-08 Cont ID  
Sent By cthroop Date 2022-10-08 Time 09:09 Rev Time 0.00
Received By cthroop Date 2022-10-08 Time 07:52 Sent To  
Notes
2022-10-08 09:12:521ST BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 1.PROVIDE THE FL PRODUCT APPROVALS OR MIAMI-DADE NOA
 FOR THE PROPOSED FRENCH DOORS.
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 NOTE: NOA???S DO NOT HAVE COVER SHEETS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 2. PLANS REQUIRE CONTRACTOR SIGNATURE. SEE COMMENTS
 UNDER SIGNATURE REVIEW.
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN.
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2022-10-29 Cont ID  
Sent By cthroop Date 2022-10-29 Time 10:42 Rev Time 0.00
Received By cthroop Date 2022-10-29 Time 10:13 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-10-21 Cont ID  
Sent By mpeterso Date 2022-10-21 Time 15:21 Rev Time 0.00
Received By mpeterso Date 2022-10-21 Time 15:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-10-13 Cont ID  
Sent By mpeterso Date 2022-10-13 Time 11:49 Rev Time 0.00
Received By mpeterso Date 2022-10-13 Time 11:49 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2022-10-28 Cont ID  
Sent By rwbrown Date 2022-10-28 Time 07:03 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2022-10-24 Cont ID  
Sent By rwbrown Date 2022-10-24 Time 07:50 Rev Time 0.00
Received By rwbrown Date 2022-10-24 Time 07:49 Sent To  
Notes
2022-10-24 07:50:222ND GAS REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2017 WPB AMENDS 107.2.1 - IT IS NOT CLEAR WHERE THE
 DRYER IS. THERE IS A GAS DETAIL THAT SHOWS 1" PE GOING
 TO A DRYER BUT THE DRYER IS NOT ON THE FLOOR PLAN.
 CLARIFY.
  
 2. 2020 FRC G2439.5 (614.6) WHEN DETAILING THE DRYER,
 PLEASE SHOW MAKEUP AIR FOR DRYER. PLEASE SHOW THE
 CALCULATION FOR THE REQUIREMENT OR EXCEPTION TO THE
 NEED FOR MAKE-UP AIR FOR THE DRYER.
  
 3. 2020 FRC G2415.17.1 (404.17.1) WHEN DETAILING THE
 GAS LINE TO THE DRYER, PLEASE NOT THAT PLASTIC GAS LINE
 SHALL BE INSTALLED OUTDOORS UNDERGROUND ONLY. IT SHALL
 NOT BE USED WITHIN OR UNDER ANY BUILDING.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-10-17 Cont ID  
Sent By rwbrown Date 2022-10-17 Time 08:54 Rev Time 0.00
Received By rwbrown Date 2022-10-17 Time 08:54 Sent To  
Notes
2022-10-17 08:59:211ST GAS REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2017 WPB AMENDS 107.2.1 - IT IS NOT CLEAR WHERE THE
 DRYER IS. THERE IS A GAS DETAIL THAT SHOWS 1" PE GOING
 TO A DRYER BUT THE DRYER IS NOT ON THE FLOOR PLAN.
 CLARIFY.
  
 2. 2020 FRC G2439.5 (614.6) WHEN DETAILING THE DRYER,
 PLEASE SHOW MAKEUP AIR FOR DRYER. PLEASE SHOW THE
 CALCULATION FOR THE REQUIREMENT OR EXCEPTION TO THE
 NEED FOR MAKE-UP AIR FOR THE DRYER.
  
 3. 2020 FRC G2415.17.1 (404.17.1) WHEN DETAILING THE
 GAS LINE TO THE DRYER, PLEASE NOT THAT PLASTIC GAS LINE
 SHALL BE INSTALLED OUTDOORS UNDERGROUND ONLY. IT SHALL
 NOT BE USED WITHIN OR UNDER ANY BUILDING.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-10-29 Cont ID  
Sent By cthroop Date 2022-10-29 Time 10:44 Rev Time 0.00
Received By cthroop Date 2022-10-27 Time 07:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-10-24 Cont ID  
Sent By rwbrown Date 2022-10-24 Time 07:50 Rev Time 0.00
Received By rwbrown Date 2022-10-19 Time 15:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-10-17 Cont ID  
Sent By rwbrown Date 2022-10-17 Time 09:05 Rev Time 0.00
Received By rwbrown Date 2022-10-03 Time 11:58 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2022-10-04 Cont ID  
Sent By medwards Date 2022-10-04 Time 09:58 Rev Time 0.00
Received By medwards Date 2022-10-04 Time 09:58 Sent To  
Notes
2022-10-04 09:59:08NO MECHANICAL WORK SHOWN ON DRAWINGS FOR THIS PROJECT.
 ME

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-10-28 Cont ID  
Sent By rwbrown Date 2022-10-28 Time 07:03 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-10-20 Cont ID  
Sent By rwbrown Date 2022-10-20 Time 08:13 Rev Time 0.00
Received By rwbrown Date 2022-10-20 Time 08:13 Sent To  
Notes
2022-10-20 08:15:032ND PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 THE FOLLOWING COMMENTS DO NOT APPEAR TO BE ADDRESSED
 FROM THE 1ST ROUND. PLEASE ADDRESS THESE COMMENTS.
  
 1. 2017 WPB AMENDS 107.2.1 - PLEASE DETAIL WHERE THE
 WASHER IS. THE ISOMETRIC SHOWS A WATER LINE TO THE
 WASHER BUT IT IS NOT LOCATED ON THE FLOOR PLAN. CLARIFY
 PLEASE.
  
 2. 2020 FRC P2906.5 - PLEASE NOTE THAT WHEN DETAILING
 THE WASHING MACHINE, THAT PVC PIPE IS NOT ALLOWED
 WITHIN ANY BUILDING.
  
 3. 2020 FRC P2801.1 REQUIRED - IT DOES NOT APPEAR THAT
 HOT WATER WAS SUPPLIED TO THE WASHING MACHINE AND IS
 REQUIRED TO BE.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-10-17 Cont ID  
Sent By rwbrown Date 2022-10-17 Time 10:04 Rev Time 0.00
Received By rwbrown Date 2022-10-05 Time 10:04 Sent To  
Notes
2022-10-17 09:04:511ST PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2017 WPB AMENDS 107.2.1 - PLEASE DETAIL WHERE THE
 WASHER IS. THE ISOMETRIC SHOWS A WATER LINE TO THE
 WASHER BUT IT IS NOT LOCATED ON THE FLOOR PLAN. CLARIFY
 PLEASE.
  
 2. 2020 FRC P2906.5 - PLEASE NOTE THAT WHEN DETAILING
 THE WASHING MACHINE, THAT PVC PIPE IS NOT ALLOWED
 WITHIN ANY BUILDING.
  
 3. 2020 FRC P2801.1 REQUIRED - IT DOES NOT APPEAR THAT
 HOT WATER WAS SUPPLIED TO THE WASHING MACHINE AND IS
 REQUIRED TO BE.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status N Date 2022-10-29 Cont ID  
Sent By cthroop Date 2022-10-29 Time 10:44 Rev Time 0.00
Received By cthroop Date 2022-10-29 Time 10:12 Sent To  
Notes
2022-10-29 10:44:35CONTRACTOR SIGNED PLANS. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-10-22 Cont ID  
Sent By cthroop Date 2022-10-22 Time 08:34 Rev Time 0.00
Received By cthroop Date 2022-10-22 Time 08:10 Sent To  
Notes
2022-10-22 08:34:50CONTRACTOR SIGNED PLANS. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-10-08 Cont ID  
Sent By cthroop Date 2022-10-08 Time 09:01 Rev Time 0.00
Received By cthroop Date 2022-10-08 Time 07:52 Sent To  
Notes
2022-10-08 09:09:051ST SIGNATURE REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE: DIGITAL SIGNATURE OF LICENSED CONTRACTORS IS
 NOT REQUIRED.
  
 1. YOU MAY SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE
 (OPTIONAL) OR REMOVE DIGITAL SIGNATURE AND SUBMIT PLANS
 SIGNED BY CONTRACTOR FOR APPLICABLE DISIPLINE.
 (BLDG., ELECTRICAL AND PLUMBING).
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT.
 481, F.S. & 61G1.
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved