| Plan Review Stops For Permit 22091180 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-10-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-29 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-29 |
Time |
10:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-10-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-22 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-22 |
Time |
08:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-10-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-08 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-08 |
Time |
07:52 |
Sent To |
|
|
| Notes |
| 2022-10-08 09:12:52 | 1ST BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | 1.PROVIDE THE FL PRODUCT APPROVALS OR MIAMI-DADE NOA | | | FOR THE PROPOSED FRENCH DOORS. | | | FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, | | | EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. | | | NOTE: NOA???S DO NOT HAVE COVER SHEETS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 2. PLANS REQUIRE CONTRACTOR SIGNATURE. SEE COMMENTS | | | UNDER SIGNATURE REVIEW. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-10-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-29 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-29 |
Time |
10:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-10-21 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-10-21 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-10-21 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-10-13 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-10-13 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-10-13 |
Time |
11:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2022-10-28 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-28 |
Time |
07:03 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2022-10-24 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-24 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-10-24 |
Time |
07:49 |
Sent To |
|
|
| Notes |
| 2022-10-24 07:50:22 | 2ND GAS REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2017 WPB AMENDS 107.2.1 - IT IS NOT CLEAR WHERE THE | | | DRYER IS. THERE IS A GAS DETAIL THAT SHOWS 1" PE GOING | | | TO A DRYER BUT THE DRYER IS NOT ON THE FLOOR PLAN. | | | CLARIFY. | | | | | | 2. 2020 FRC G2439.5 (614.6) WHEN DETAILING THE DRYER, | | | PLEASE SHOW MAKEUP AIR FOR DRYER. PLEASE SHOW THE | | | CALCULATION FOR THE REQUIREMENT OR EXCEPTION TO THE | | | NEED FOR MAKE-UP AIR FOR THE DRYER. | | | | | | 3. 2020 FRC G2415.17.1 (404.17.1) WHEN DETAILING THE | | | GAS LINE TO THE DRYER, PLEASE NOT THAT PLASTIC GAS LINE | | | SHALL BE INSTALLED OUTDOORS UNDERGROUND ONLY. IT SHALL | | | NOT BE USED WITHIN OR UNDER ANY BUILDING. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-10-17 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-17 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-10-17 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2022-10-17 08:59:21 | 1ST GAS REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2017 WPB AMENDS 107.2.1 - IT IS NOT CLEAR WHERE THE | | | DRYER IS. THERE IS A GAS DETAIL THAT SHOWS 1" PE GOING | | | TO A DRYER BUT THE DRYER IS NOT ON THE FLOOR PLAN. | | | CLARIFY. | | | | | | 2. 2020 FRC G2439.5 (614.6) WHEN DETAILING THE DRYER, | | | PLEASE SHOW MAKEUP AIR FOR DRYER. PLEASE SHOW THE | | | CALCULATION FOR THE REQUIREMENT OR EXCEPTION TO THE | | | NEED FOR MAKE-UP AIR FOR THE DRYER. | | | | | | 3. 2020 FRC G2415.17.1 (404.17.1) WHEN DETAILING THE | | | GAS LINE TO THE DRYER, PLEASE NOT THAT PLASTIC GAS LINE | | | SHALL BE INSTALLED OUTDOORS UNDERGROUND ONLY. IT SHALL | | | NOT BE USED WITHIN OR UNDER ANY BUILDING. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-10-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-29 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-27 |
Time |
07:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-10-24 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-24 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-10-19 |
Time |
15:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-10-17 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-17 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-10-03 |
Time |
11:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2022-10-04 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-10-04 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-04 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2022-10-04 09:59:08 | NO MECHANICAL WORK SHOWN ON DRAWINGS FOR THIS PROJECT. | | | ME |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2022-10-28 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-28 |
Time |
07:03 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-10-20 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-20 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-10-20 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2022-10-20 08:15:03 | 2ND PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | THE FOLLOWING COMMENTS DO NOT APPEAR TO BE ADDRESSED | | | FROM THE 1ST ROUND. PLEASE ADDRESS THESE COMMENTS. | | | | | | 1. 2017 WPB AMENDS 107.2.1 - PLEASE DETAIL WHERE THE | | | WASHER IS. THE ISOMETRIC SHOWS A WATER LINE TO THE | | | WASHER BUT IT IS NOT LOCATED ON THE FLOOR PLAN. CLARIFY | | | PLEASE. | | | | | | 2. 2020 FRC P2906.5 - PLEASE NOTE THAT WHEN DETAILING | | | THE WASHING MACHINE, THAT PVC PIPE IS NOT ALLOWED | | | WITHIN ANY BUILDING. | | | | | | 3. 2020 FRC P2801.1 REQUIRED - IT DOES NOT APPEAR THAT | | | HOT WATER WAS SUPPLIED TO THE WASHING MACHINE AND IS | | | REQUIRED TO BE. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-10-17 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-17 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-10-05 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2022-10-17 09:04:51 | 1ST PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2017 WPB AMENDS 107.2.1 - PLEASE DETAIL WHERE THE | | | WASHER IS. THE ISOMETRIC SHOWS A WATER LINE TO THE | | | WASHER BUT IT IS NOT LOCATED ON THE FLOOR PLAN. CLARIFY | | | PLEASE. | | | | | | 2. 2020 FRC P2906.5 - PLEASE NOTE THAT WHEN DETAILING | | | THE WASHING MACHINE, THAT PVC PIPE IS NOT ALLOWED | | | WITHIN ANY BUILDING. | | | | | | 3. 2020 FRC P2801.1 REQUIRED - IT DOES NOT APPEAR THAT | | | HOT WATER WAS SUPPLIED TO THE WASHING MACHINE AND IS | | | REQUIRED TO BE. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
N |
Date |
2022-10-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-29 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-29 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2022-10-29 10:44:35 | CONTRACTOR SIGNED PLANS. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-10-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-22 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-22 |
Time |
08:10 |
Sent To |
|
|
| Notes |
| 2022-10-22 08:34:50 | CONTRACTOR SIGNED PLANS. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-10-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-08 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-08 |
Time |
07:52 |
Sent To |
|
|
| Notes |
| 2022-10-08 09:09:05 | 1ST SIGNATURE REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: DIGITAL SIGNATURE OF LICENSED CONTRACTORS IS | | | NOT REQUIRED. | | | | | | 1. YOU MAY SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE | | | (OPTIONAL) OR REMOVE DIGITAL SIGNATURE AND SUBMIT PLANS | | | SIGNED BY CONTRACTOR FOR APPLICABLE DISIPLINE. | | | (BLDG., ELECTRICAL AND PLUMBING). | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | | 481, F.S. & 61G1. | | | | | | |
|
|