Plan Review Details - Permit 22090869
| Plan Review Stops For Permit 22090869 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-02-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-02-24 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-02-24 |
Time |
13:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2023-01-25 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2023-01-25 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2023-01-25 08:57:55 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. RESPONSE LETTER STATES THAT PROFLEX SUPERSIM 90 IS | | | PROPOSED. THE FLAME SPREAD TEST IS FOR TILE. IT IS NOT | | | CLEAR IF THE ASSEMBLY MEETS THE FLAME SPREAD | | | REQUIREMENT SINCE A COMBUSTIBLE FLOORING APPEARS TO BE | | | PROPOSED. (APPEARS TO BE A LAMINATE FLOORING, VM HS | | | PALM ACACIA FLOORING). NOTE THAT WE HAVE PROFLEX LV200 | | | TEST REPORTS ON FILE (INCLUDES STC, IIC, FLAME SPREAD). | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-11-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-11-16 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-11-16 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2022-11-16 15:51:47 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | TEST REPORTS SUBMITTED: | | | STC - PROFLEX MSC90, 8" SLAB, QUARRY TILE | | | IIC - THE STC TEST REPORT WAS UPLOADED TWICE, ONCE | | | NAMED IMPACT SOUND TRANSMISSION | | | ASTME-84 - PROFLEX SUPERSIM 90 | | | | | | 1. FBC 107, NOT CLEAR WHICH PRODUCT IS PROPOSED. IF | | | MSC90 IS PROPOSED, ADVISE HOW YOU HAVE DETERMINED THAT | | | THE SLAB IS 8". | | | | | | IF SUPERSIM 90 IS PROPOSED, PLEASE ADVISE VIA A | | | RESUBMITTAL LETTER, THE STC/IIC TEST REPORTS WILL BE | | | UPLOADED FOR YOU. | | | | | | FBC B 1207, FBC B 603.1. | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-01-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-01-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-01-04 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2022-10-12 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-10-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-10-12 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2022-10-12 12:26:33 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE IS AN INDICATION OF THE SPEC SHEETAND FLAME | | | TEST FOR THE FLOOR SOUND UNDERLAYMENT, BUT NO SPEC | | | SHEET NOR A PRODUCT NAME FOR THE ACTUAL PROPOSED | | | WOOD/ENGINEERED WOOD FLOORING. | | | | | | ENGINEERED WOOD FLOORING CAN BE MANUFACTURED FROM | | | AROUND THE WORLD AND NOT ALL ARE TESTED AND MEETING | | | LISTED AND NFPA STANDARDS. | | | | | | PER NFPA 101, CH 30 | | | | | | 30.3.3.3 INTERIOR FLOOR FINISH. | | | 30.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN | | | ACCORDANCE WITH | | | SECTION 10.2. | | | | | | 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH | | | 10.2.2.2 | | | ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL | | | HAVE A | | | MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2. | | | | | | FOR THE OFFICIAL RECORD, PLEASE PROVIDE THE ENGINEERED | | | WOOD FLOORING NAME AND THE PRODUCT SPEC SHEETS OF THE | | | PROPOSED ENGINEERED WOOD FLOORING INDICATING THE FIRE | | | BEHAVIOR RATING. | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-02-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-02-24 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-02-22 |
Time |
07:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2023-01-25 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2023-01-04 |
Time |
05:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-11-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-11-16 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-09-23 |
Time |
10:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2022-11-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-11-16 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-11-16 |
Time |
15:51 |
Sent To |
|
|
| Notes |
|
|
|