| Plan Review Stops For Permit 22090842 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
N |
Date |
2023-02-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-06 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-06 |
Time |
09:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-11-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-11-14 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-11-14 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2022-11-14 16:03:29 | VEHICLE CHARGING STATION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) ELECTRIC VEHICLE CHARGING STATIONS ARE BEING | | | INSTALLED - PLEASE SHOW THAT AT LEAST 1 OF THE CHARGING | | | STATIONS IS AN ACCESSIBLE PARKING SPACE, ACCESS AISLE, | | | SIGNAGE ETC. PER FBC 502 | | | FBC 406.1.7 ELECTRIC VEHICLE CHARGING STATIONS. | | | ACCESSIBILITY TO ELECTRIC VEHICLE CHARGING STATIONS | | | SHALL BE PROVIDED IN ACCORDANCE WITH CHAPTER 11. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2023-02-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-02-27 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-02-27 |
Time |
07:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2023-02-09 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-02-09 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-02-09 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2023-02-09 14:27:32 | VALUE TO INCLUDE THE CHARGER AND OTHER MATERIALS TO | | | COMPLETE THE INSTALLATION INCLUDING LABOR. | | | | | | PLEASE SUBMIT A VALUE THAT REFLECTS THE WORKING BEING | | | DONE. JLEAHY (1.5K) |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-10-31 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-10-31 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-10-21 |
Time |
17:15 |
Sent To |
|
|
| Notes |
| 2022-10-31 07:45:19 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 625.43 DISCONNECTING MEANS. | | | | | | FOR EQUIPMENT RATED MORE THAN 60 AMPERES OR MORE THAN | | | 150 VOLTS TO GROUND, THE DISCONNECTING MEANS SHALL BE | | | PROVIDED AND INSTALLED IN A READILY ACCESSIBLE | | | LOCATION. THE DISCONNECTING MEANS SHALL BE LOCKABLE | | | OPEN IN ACCORDANCE WITH 110.25 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-02-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-02-27 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-02-14 |
Time |
07:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-02-13 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-02-03 |
Time |
11:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-11-21 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-11-21 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-10-12 |
Time |
09:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-02-09 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-02-09 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-02-09 |
Time |
14:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-10-31 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-10-31 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-10-21 |
Time |
17:15 |
Sent To |
|
|
| Notes |
| 2022-10-31 07:47:42 | PLAN SIGNATURE IS NOT DIGITALLY VERIFIABLE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-02-13 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-02-13 |
Time |
11:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-11-21 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-11-21 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-11-21 |
Time |
12:52 |
Sent To |
|
|
| Notes |
| 2022-11-21 12:59:12 | 11/21/2022 FAILED | | | | | | PLEASE PROVIDE A SURVEY OR SITE PLAN INDICATING THE | | | TOTAL NUMBER OF PARKING SPACES REQUIRED PER THE USE OF | | | THE BUILLDING. | | | PLEASE INCLUDE A PROPOSED LOCATION OF THE CHARING | | | STATION, PLEASE NOTE A CHARGING STATION MAY NOT OCCUPIE | | | REQUIRED PARKING | | | | | | PLEASE SHOW THE FACE OF THE PROPOSED SIGN, AS THIS MAY | | | REQUIRE A SEPARTE PERMIT | | | | | | | | | **** REVIEWD BY **** | | | VALENTINA BROGLIA | | | ASSOCIATE PLANNER | | | [email protected] | | | |
|
|