Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-10-19 Cont ID  
Sent By rmcphers Date 2022-10-19 Time 14:51 Rev Time 0.00
Received By rmcphers Date 2022-10-19 Time 14:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-10-14 Cont ID  
Sent By jbrooks Date 2022-10-14 Time 12:46 Rev Time 0.00
Received By jbrooks Date 2022-10-14 Time 07:58 Sent To  
Notes
2022-10-14 12:46:51JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL16717-R12
 (HVHZ) IS NOT APPROVED FOR USE OUTSIDE HVHZ. CITY OF
 WEST PALM BEACH IS NOT LOCATED IN A HVHZ. YOU MIGHT
 CONSIDER USING FL1654-R29 (NON-HVHZ).
 2. FBC B 107.2.1 MIAMI-DADE COUNTY NOA NO. 21-1217.02
 WILL BE ACCEPTED FOR DIRECT-TO-DECK INSTALLATIONS BY
 THE CITY OF WEST PALM BEACH. NOTE: FL17084-R10 IS NOT
 APPROVED FOR USE AS A SEAM TAPE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-10-04 Cont ID  
Sent By jbrooks Date 2022-10-04 Time 10:17 Rev Time 0.00
Received By jbrooks Date 2022-10-04 Time 07:51 Sent To  
Notes
2022-10-04 10:17:32JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL
 FL1654-R29 IS INCOMPLETE, PROVIDE THE FOLLOWING
 ADDITIONAL INFORMATION: COVER SHEET
 (WWW.FLORIDABUILDING.ORG, THIS WILL INCLUDE THE CODE
 VERSION, PRODUCT APPROVAL NUMBER, STATUS, GENERAL
 INFORMATION ABOUT THE PRODUCT).
 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL1654-R29 SYSTEM NO. W-111 DOES NOT MEET THE
 MINIMUM ZONE 3 DESIGN PRESSURE REQUIREMENT OF -108.17
 FOR EXPOSURE CATEGORY C AREAS. PROVIDE SYSTEM THAT
 MEETS OR EXCEEDS ALL DESIGN PRESSURE REQUIREMENTS FOR
 EXPOSURE CATEGORY C/PROVIDE SIGNED AND SEALED
 ENGINEERED NAILING CALCULATIONS WITH AN APPROVED
 SYSTEM.
 3. FBC R 301 FAC9N-3 SUBMITTED MIAMI-DADE COUNTY NOA
 21-1217.02 SELECT INSTALLATION PROCEDURE SYSTEM TYPE
 E(1), E(2) OR E(3) IT DO NOT ALLOW FOR DIRECT-TO-DECK
 INSTALLATION. THE CITY OF WEST PALM BEACH WILL NOT
 ACCEPT DIRECT-TO-DECK METHOD OF INSTALLATION FOR THIS
 NOA.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-09-21 Cont ID  
Sent By jbrooks Date 2022-09-21 Time 09:38 Rev Time 0.00
Received By jbrooks Date 2022-09-21 Time 07:40 Sent To  
Notes
2022-09-21 09:38:25JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL10124-R31
 HAS BEEN REVISED TO FL10124-R32. PLEASE PROVIDE A
 COMPLETE SET; IT COVERS MULTIPLE PRODUCTS &
 INSTALLATION METHODS. SELECT PRODUCT & INSTALLATION
 METHOD TO BE USED. ALL APPLICABLE DETAILS AND
 ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT
 APPROVAL DRAWINGS.
 2. FBC B 107.2.1. SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL17084-R10 IS NOT APPROVED FOR USE AS A SEAM
 TAPE. PROVIDE A COMPLETE SET OF 2020 CODE VERSION
 PRODUCT APPROVALS/NOA'S FOR THE PROPOSED ROOF
 UNDERLAYMENT (JOINT TAPE/STRIPS) TO BE USED. INCLUDE
 COVER PAGE, EVALUATION REPORTS AND INSTALLATION
 INSTRUCTIONS FOR SYSTEM USED. ALL APPLICABLE DETAILS
 AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE
 PRODUCT APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS NOT
 SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED
 SITE-SPECIFIC ENGINEERING. OPTION FL12328-R9 (NON-HVHZ)
 3. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL16717-R12
 (HVHZ) IS NOT APPROVED FOR USE OUTSIDE HVHZ. CITY OF
 WEST PALM BEACH IS NOT LOCATED IN A HVHZ. YOU MIGHT
 CONSIDER USING FL1654-R29 (NON-HVHZ).
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-10-19 Cont ID  
Sent By rmcphers Date 2022-10-19 Time 14:51 Rev Time 0.00
Received By rmcphers Date 2022-10-17 Time 07:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-10-14 Cont ID  
Sent By jbrooks Date 2022-10-14 Time 12:47 Rev Time 0.00
Received By jbrooks Date 2022-10-06 Time 08:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-10-04 Cont ID  
Sent By jbrooks Date 2022-10-04 Time 10:17 Rev Time 0.00
Received By jbrooks Date 2022-09-29 Time 10:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-09-21 Cont ID  
Sent By jbrooks Date 2022-09-21 Time 09:39 Rev Time 0.00
Received By jbrooks Date 2022-09-20 Time 09:11 Sent To  
Notes
***NONE***