Plan Review Details - Permit 22090658
Plan Review Stops For Permit 22090658
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-10-13 Cont ID  
Sent By rmcdouga Date 2022-10-13 Time 17:16 Rev Time 0.00
Received By rmcdouga Date 2022-10-13 Time 17:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-10-04 Cont ID  
Sent By rmcdouga Date 2022-10-04 Time 15:36 Rev Time 0.00
Received By rmcdouga Date 2022-10-04 Time 15:36 Sent To  
Notes
2022-10-04 15:51:22PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE MAXIMUM DESIGN PRESSURE FOR THE BUILT UP ROOF
 FASTENING THAT WAS SELECTED ON PAGE 23 IS -52.5 PSF
 WHICH IS NOT ADEQUATE FOR THE PERIMETER AND CORNER
 AREAS OF THE ROOF. SUBMIT SIGNED AND SEALED ENHANCED
 FASTENING CALCULATIONS IN ACCORDANCE WITH LIMITATION #7
 ON PAGE 27 OF THE NOA.