Plan Review Details - Permit 22090583
Plan Review Stops For Permit 22090583
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-10-13 Cont ID  
Sent By rgathrig Date 2022-10-13 Time 11:00 Rev Time 0.00
Received By rgathrig Date 2022-10-13 Time 11:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-09-19 Cont ID  
Sent By jwitmer Date 2022-09-19 Time 11:50 Rev Time 0.00
Received By jwitmer Date 2022-09-19 Time 11:10 Sent To  
Notes
2022-09-19 11:50:01WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. REVISION: 22090583
 W. P. B. PERMIT: 22021141
 ADD: 4 HARVARD CIRCLE
 CONT: VERTEX
 TEL: 561-619-7722
 E-MAIL: [email protected]
  
 1) LIFE SAFETY SHEET SHOWS OCCUPANT LOAD FOR BUILDING
 AT 16 PERSONS BUT NOT THE PLUMBING OCCUPANT LOAD PER
 2020 FBC-BUILDING TABLE 2902.1. THE OCCUPANT LOAD
 FACTOR IS STILL 100 NOT THE 150 OF THE BUILDING CODE
 MAKING THE PLUMBING OCCUPANT LOAD 24 PERSONS. SEE
 SECTION 2902.6 OCCUPANT LOADS 15 OR LESS DO NOT NEED TO
 MEET THE DRINKING FOUNTAIN REQUIREMENTS BUT OVER 15
 OCCUPANTS NEED TO SHOW COMPLIANCE WITH:
 1A) 2020 FBC-ACCESSIBILITY CODE. 211.2 MINIMUM NUMBER.
 NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED.
 ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH
 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH
 602.7.
  
 1B) PROTRUDING OBJECTS 307.2 PROTRUSION LIMITS 307.2.
 OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES AND NOT
 MORE THAN 80 INCHES ABOVE THE FLOOR SHALL NOT PROTRUDE
 MORE THAN 4 INCHES HORIZONTALLY INTO THE CIRCULATION
 PATH.
  
 1C) 602.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE
 COMPLYING WITH 305, POSITIONED FOR A FORWARD APPROACH,
 AND KNEE AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE
 PROVIDED.
  
 1D) SPOUT OUTLETS/ DRINKING FOUNTAINS. 2017 ACCESS.
 CODE. SPOUT OUTLETS SHALL COMPLY WITH:
 1D)(1) 602.4 SPOUT HEIGHT. 36 INCHES MAXIMUM ABOVE THE
 FINISH FLOOR OR GROUND FOR WHEELCHAIR BOUND
 INDIVIDUALS.
 1D)(2) 602.7 SPOUT HEIGHT FOR THE STANDING PERSONS
 SHALL BE BETWEEN 38 TO 43 INCHES ABOVE FINISH FLOOR.
  
 2) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-09-23 Cont ID  
Sent By fgiaquin Date 2022-09-23 Time 21:00 Rev Time 0.00
Received By fgiaquin Date 2022-09-23 Time 19:48 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-09-29 Cont ID  
Sent By cwalker Date 2022-09-29 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-09-19 Cont ID  
Sent By cwalker Date 2022-09-19 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-10-13 Cont ID  
Sent By aoliver Date 2022-10-13 Time 16:07 Rev Time 0.00
Received By aoliver Date 2022-09-27 Time 09:35 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-09-23 Cont ID  
Sent By fgiaquin Date 2022-09-23 Time 21:00 Rev Time 0.00
Received By fgiaquin Date 2022-09-16 Time 10:12 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-09-19 Cont ID  
Sent By medwards Date 2022-09-19 Time 13:37 Rev Time 0.00
Received By medwards Date 2022-09-19 Time 13:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-09-30 Cont ID  
Sent By rwbrown Date 2022-09-30 Time 07:59 Rev Time 0.00
Received By rwbrown Date 2022-09-30 Time 07:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-09-19 Cont ID  
Sent By rwbrown Date 2022-09-19 Time 09:13 Rev Time 0.00
Received By rwbrown Date 2022-09-19 Time 09:13 Sent To  
Notes
2022-09-19 09:16:131ST PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
  
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FPC - 607.1.1 TEMPERATURE LIMITING MEANS - THE
 THERMOSTAT CONTROL ON THE WATER HEATER CANNOT BE THE
 LIMITING DEVICE FOR HOT WATER DELIVERY. PLEASE PROVIDE
 A DETAIL FOR A LIMITING DEVICE FOR THE PURPOSE OF HOT
 WATER DELIVERY. THIS WOULD BE IN ADDITION TO THE
 DEVICES REQUIRED FOR TEMPERED WATER FOR PUBLIC
 HANDWASHING 607.1.2/419.5. AND, SHALL BE INSTALLED AT
 THE HOT WATER SOURCE PER 613.1.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-10-13 Cont ID  
Sent By rgathrig Date 2022-10-13 Time 11:01 Rev Time 0.00
Received By rgathrig Date 2022-10-13 Time 11:01 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-09-19 Cont ID  
Sent By rwbrown Date 2022-09-19 Time 09:17 Rev Time 0.00
Received By rwbrown Date 2022-09-19 Time 09:17 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved