Plan Review Details - Permit 22090497
| Plan Review Stops For Permit 22090497 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-11-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-11-17 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-11-17 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-10-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-10-27 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-10-27 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2022-10-27 15:37:29 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE TWO TEST REPORTS FOR SOUND WERE DONE WITH | | | SUSPENDED CEILINGS BELOW THE SIX INCH CONCRETE SLABS. | | | THE TESTS HAVE TO REPRESENT THE CONDITIONS AT THE SITE | | | WHERE THE PRODUCT IS BEING INSTALLED. SUBMIT THE | | | APPROPRIATE TEST REPORTS. | | | FBC 1207.2 AIR-BORNE SOUND. ASTM E 90-04 | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E 492-09 | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-10-31 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-10-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-10-31 |
Time |
11:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2022-09-16 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-09-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-09-16 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2022-09-16 11:30:22 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE IS AN INDICATION OF THE SPEC SHEET FOR THE | | | FLOOR UNDERLAYMENT, BUT NO SPEC SHEET NOR A PRODUCT | | | NAME FOR THE ACTUAL PROPOSED LAMINATE FLOORING. | | | | | | LAMINATE FLOORING IS MANUFACTURED AROUND THE WORLD AND | | | NOT ALL ARE TESTED AND MEETING LISTED AND NFPA | | | STANDARDS. | | | | | | PER NFPA 101, CH 30 | | | | | | 30.3.3.3 INTERIOR FLOOR FINISH. | | | 30.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN | | | ACCORDANCE WITH | | | SECTION 10.2. | | | | | | 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH | | | 10.2.2.2 | | | ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL | | | HAVE A | | | MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2. | | | | | | FOR THE OFFICIAL RECORD, PLEASE PROVIDE THE LAMINATE | | | FLOORING NAME AND THE PRODUCT SPEC SHEETS OF THE | | | PROPOSED FINISHED | | | LAMINATE FLOORING INDICATING THE FIRE BEHAVIOR RATING. | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-11-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-11-17 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-10-28 |
Time |
16:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-10-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-10-27 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-09-15 |
Time |
15:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2022-10-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-10-27 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-10-27 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
|