Plan Review Details - Permit 22090321
| Plan Review Stops For Permit 22090321 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-12-14 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2022-12-14 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2022-12-14 |
Time |
16:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-11-28 |
|
|
Cont ID |
|
| Sent By |
eroseber |
Date |
2022-11-28 |
Time |
18:46 |
Rev Time |
0.00 |
| Received By |
eroseber |
Date |
2022-11-28 |
Time |
18:46 |
Sent To |
|
|
| Notes |
| 2022-11-28 18:48:31 | 1. PLEASE HIGHLIGHT FBC/NOA WITH INSTALLATION | | | CONFIGURATION/PRODUCT SIZES DESIGN PRESSURES. FBC 107.2 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-10-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-10-22 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-10-22 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2022-10-22 16:11:01 | [email protected] | | | [email protected] | | | | | | 1. CONTRACTOR FURNISHED INFORMATION, WHICH ENGINEERED | | | DESIGN PRESSURE REQUIREMENTS ARE BASED ON, STATE LOWEST | | | ELEVATION INSTALLATION TO BE 10'. AS THIS IS A | | | PENTHOUSE WITH 170' MRH, THIS DOES NOT APPEAR TO BE | | | CORRECT DATA. PLEASE VERIFY AND RESUBMIT CORRECTION OR | | | CLARIFICATION. FBC 107.2 | | | 2. PLEASE PROVIDE A FLASHING DETAIL, OR ADD A NOTE TO | | | THE PLAN, DEMONSTRATING COMPLIANCE WITH FBC R 703.4 OR | | | FBC B 1405.4. | | | DIGITAL SIGNATURE- APPROVED PENDING COMMENT RESPONSE. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-12-14 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2022-12-14 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2022-11-30 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
F |
Date |
2022-11-28 |
|
|
Cont ID |
|
| Sent By |
eroseber |
Date |
2022-11-28 |
Time |
18:48 |
Rev Time |
0.00 |
| Received By |
eroseber |
Date |
2022-11-16 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-10-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-10-22 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-09-27 |
Time |
08:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-12-14 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2022-12-14 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2022-12-14 |
Time |
16:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-11-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-11-16 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-11-16 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2022-11-16 10:08:30 | SIGNED AND SEALED CALCULATIONS ON PAPER SENT TO | | | STORAGE/CC. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-10-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-10-22 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-10-22 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2022-10-22 16:11:21 | SEE BUILDING | | | |
|
|
|