Plan Review Details - Permit 22090300
| Plan Review Stops For Permit 22090300 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-11-29 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-11-29 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-11-29 |
Time |
13:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-10-18 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-10-18 |
Time |
11:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-11-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-11-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-11-15 |
Time |
11:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2022-10-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-10-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-10-04 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2022-10-04 13:41:09 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE IS NO INDICATION SHOWING THE LOCATION OF THE | | | DIESEL TANK FILL PORT. | | | | | | PER NFPA 1 CH 42 | | | | | | 42.7.2.2 TANK FILLING AND BULK DELIVERY. | | | 42.7.2.2.1 DELIVERY OPERATIONS SHALL MEET ALL | | | APPLICABLE RE QUIREMENTS OF NFPA 385 AND THE | | | REQUIREMENTS OF 42.7.2.2.3 | | | THROUGH 42.7.2.2.46. [30A:9.2.2.1] | | | 42.7.2.2.3 THE DELIVERY VEHICLE SHALL BE SEPARATED FROM | | | ANY | | | ABOVEGROUND TANK IN ACCORDANCE WITH TABLE42.7.2.2.3. | | | | | | 42.7.2.2.3.1 SEPARATION DISTANCES SHALL BE SEPARATED BY | | | THE USE OF CURBING, GUARD POSTS, OR OTHER APPROVED | | | METHODS. | | | | | | PLEASE REIVEW AND PROVIDE DETAILS IN COMPLIANCE WITH | | | THE ABOVE CODES AS WELL AS OTHER APPLICABLE CODES OF CH | | | 42. | | | | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-11-29 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-11-29 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-11-14 |
Time |
09:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-10-18 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-09-30 |
Time |
06:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-11-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-11-18 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-11-18 |
Time |
14:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-10-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-10-13 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-13 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2022-10-13 14:03:27 | 1ST REVIEW FMC | | | PERMIT: 22090300 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) APPLICATION IS FOR FUEL SYSTEM INSTALL OF ABOVE | | | GROUND TANK, FUEL PIPE, FUEL FILTRATION, FUEL PORT AND | | | FUEL PUMP. SHEET M.301C: GENERAL NOTES 1 STATES REFER | | | TO PIPING RISER DIAGRAMS M.703, M.704, M.705, M.708, | | | M.709 AND M.710 FOR PIPING SIZES. THESE SHEETS WERE NOT | | | SUBMITTED. PLEASE SUBMIT A COMPLETE DESIGN SO THIS | | | REVIEWER CAN COMPLETE THE FUEL SYSTEM DESIGN REVIEW. I | | | DID NOT DO A REVIEW AS THESE DOCUMENTS WERE MISSING. | | | FBC 107.3.5 | | | | | | 2) IT APPEARS THAT THIS DESIGN IS FOR THE FUEL OIL | | | TANKS ALSO. PROVIDE INFORMATION FOR THE TANK. FBC | | | 107.3.5 | | | | | | 3) IS THE PERMIT APPLICATION ALSO FOR THE GENERATORS? | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-11-29 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-11-29 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-11-29 |
Time |
13:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-10-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-10-13 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-13 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2022-10-13 14:05:07 | THE EOR MUST DIGITALLY SIGN THE DOCUMENTS. FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
|