|
 |
 |
 |
 |
 |
Plan Review Details - Permit 22090114
| Plan Review Stops For Permit 22090114 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2022-10-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-10-24 |
Time |
15:01 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-10-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-10-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-10-26 |
Time |
11:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2022-09-08 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-09-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-09-08 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2022-09-08 11:22:07 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE ARE INDICATIONS OF THE SPEC SHEETS FOR THE | | | FLOOR UNDERLAYMENT, BUT NO MANUFACTURE'S SPEC SHEET FOR | | | THE ACTUAL PROPOSED CLICK VINYL FLOORING. | | | | | | CLICK VINYL FLOORING IS MANUFACTURED AROUND THE WORLD | | | AND NOT ALL ARE TESTED AND MEETING LISTED AND NFPA | | | STANDARDS. | | | | | | PER NFPA 101, CH 30 | | | | | | 30.3.3.3 INTERIOR FLOOR FINISH. | | | 30.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN | | | ACCORDANCE WITH | | | SECTION 10.2. | | | | | | 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH | | | 10.2.2.2 | | | ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL | | | HAVE A | | | MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2. | | | | | | FOR THE OFFICIAL RECORD, PLEASE PROVIDE THE PRODUCT | | | SPEC SHEETS OF THE PROPOSED FINISHED | | | CLICK VINYL FLOORING INDICATING THE FIRE BEHAVIOR | | | RATING. | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-10-26 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-10-26 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-10-25 |
Time |
15:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-10-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
cdecoeur |
Date |
2022-09-07 |
Time |
07:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2022-10-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-10-24 |
Time |
15:01 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |