| Plan Review Stops For Permit 22081447 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2023-01-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-06 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-06 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-12-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-12-30 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-12-30 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2022-12-30 11:31:07 | 3RD BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: WINDOW SCHEDULE ON PLAN PAGE A.3 INDICATES | | | FIXED WINDOWS WILL BE INSTALLED. | | | | | | 1.PROVIDE THE FL PRODUCT APPROVALS FOR THE PROPOSED | | | WINDOWS. | | | FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, | | | EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. | | | NOTE: NOAS DO NOT HAVE COVER SHEETS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | NOTICE: 2 COPIES OF NOA 19-0918.03 WERE SUBMITTED FOR | | | REVIEW. THESE ARE NOT LISTED ON THE DOOR SCHEDULE OR | | | REFERENCED ON THE FLOOR PLAN. IF THESE SWINGING DOORS | | | ARE TO BE INSTALLED, PLEASE LOCATE THEM ON THE PLANS. | | | IF NOT, PLEASE REMOVE THEM FROM YOUR SUBMITTAL. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-11-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-17 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-11-17 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2022-11-17 11:08:25 | 2ND BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | 1.PROVIDE THE FL PRODUCT APPROVALS FOR THE PROPOSED | | | WINDOWS AND EXT. DOORS. | | | FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, | | | EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. | | | NOTE: NOAS DO NOT HAVE COVER SHEETS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 2. PLAN PAGE A-2 INDICATES THE 2ND STORY BALCONY WILL | | | BE ENCLOSED. PROVIDE DETAILED PLANS, INCLUDE ALL | | | DEMENSIONS. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 3.PROVIDE SMOKE ALARMS. ALARMS ARE MISSING OUTSIDE 1ST | | | FLOOR MASTER BEDROOM AND LIBRARY/BEDROOM. | | | FBC 1104.1SMOKE ALARMS IN EXISTING PORTIONS OF A | | | BUILDING. | | | | | | R314.2.2ALTERATIONS, REPAIRS AND ADDITIONS. | | | WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC R314. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-10-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-21 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-21 |
Time |
05:36 |
Sent To |
|
|
| Notes |
| 2022-10-21 14:04:10 | 1ST BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | 1. PLAN QUALITY IS POOR. CANNOT READ TEXT. RE-SUBMIT | | | PLANS FOR REVIEW. | | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-12-14 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-12-14 |
Time |
20:11 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-12-14 |
Time |
18:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-11-02 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-11-02 |
Time |
22:54 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-11-02 |
Time |
21:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-10-04 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-10-04 |
Time |
23:14 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-10-04 |
Time |
22:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-01-17 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2023-01-17 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2023-01-06 |
Time |
07:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-12-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-12-30 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-12-09 |
Time |
10:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-11-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-17 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-26 |
Time |
16:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-10-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-21 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-09-19 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-12-14 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2022-12-14 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2022-12-14 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2022-12-14 12:58:38 | THE MECHANICAL NOTES ON THE NEW MECHANICAL DRAWING 1-8 | | | APPEAR TO BE FOR THE MECHANICAL SYSTEM AND NOT FOR JUST | | | THE KITCHEN HOOD AND BATH EXHAUST FANS SHOWN ON THE | | | DRAWINGS. IS THERE TO BE ANY MECHANICAL SYTEM WORK TO | | | BE COMPLETED IN THIS PROJECT THAT ISN'T SHOWN ON THE | | | NEW MECHANICAL DRAWING? IF SO, PLEASE SHOW ALL WORK TO | | | BE COMPLETED ON THE MECHANICAL DRAWING. IF THESE NOTES | | | DO NOT APPLY TO THIS PROJECT PLEASE REMOVE THEM SO | | | THERE IS NO CONFUSION AS TO THE SCOPE OF THE MECHANICAL | | | WORK TO BE COMPLETED UNDER THIS PEROJECT. A MECHANICAL | | | SUB PERMIT WILL BE REQUIRED FOR THIS PROJECT. FBC | | | 107.3.5 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-11-04 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-11-04 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-11-04 |
Time |
08:12 |
Sent To |
|
|
| Notes |
| 2022-11-04 08:12:51 | 1ST REVIEW FMC | | | PERMIT: 22081447 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | THERE ARE MECHANICAL CHANGES TO THIS PROJECT. PROVIDE A | | | MECHANICAL DRAWING INDICATING ALL MECHANICAL CHANGES TO | | | THIS PROJECT: PARTIAL LIST SEEN ON THE DRAWINGS??? | | | DRYER TO BE RELOCATED, NEW BATHROOM FOR THE | | | LIBRARY/BEDROOM- BATH EXHAUST REQUIRED? RANGE BEING | | | RELOCATED, IS THERE TO BE A DUCTED HOOD ABOVE THE RANGE | | | IN THE NEW LOCATION? CFM???S OF THE FAN MOTOR FOR THE | | | HOOD? | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-09-20 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-20 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-20 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2022-09-20 11:09:07 | 1) PLANS SUBMITTED ARE COPIES AND ARE BLURRY, CANNOT | | | READ. PLEASE SUBMIT CLEAR DRAWINGS. FBC 107.3.5 | | | | | | 2) THERE ARE NO MECHANICAL DOCUMENTS IN THIS SUBMITTAL, | | | PROVIDE MECHANICAL SCOPE OF WORK ALONG WITH DRAWINGS. | | | FBC 107.3.5 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-10-28 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-28 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-10-28 |
Time |
07:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-09-20 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-09-20 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-09-20 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2022-09-20 11:05:10 | 1ST PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. I AM UNABLE TO REVIEW. THE RESOLUTION ON THE PLANS | | | HAVE MADE IT UNCLEAR ON THE RISER DIAGRAM AND SOME OF | | | THE NOTATIONS. PLEASE RESOLVE. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2023-01-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-06 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-06 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-12-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-12-30 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-12-30 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2022-12-14 12:59:31 | MECHANICAL DIGITAL SIGNATURES APPROVED ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-11-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-17 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-11-17 |
Time |
11:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-09-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-09-19 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-09-19 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2022-09-19 16:36:43 | 8.5 X 11 INCH PAPER PLANS WITH COPIES OF DIGITAL | | | SIGNATURES WERE SUBMITTED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2023-01-17 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2023-01-17 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2023-01-17 |
Time |
17:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-12-30 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2022-12-30 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2022-12-30 |
Time |
09:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-11-03 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-11-03 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-11-03 |
Time |
15:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-09-22 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-09-22 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-09-22 |
Time |
10:51 |
Sent To |
|
|
| Notes |
|
|