| 2022-09-19 10:54:33 | INDICATE AREAS OF PROPOSED DRIVEWAY CONSTRUCTION ON A |
| | COPY OF THE PROPERTY SURVEY. DIMENSION DRIVEWAYS, |
| | LOCATED HORIZONTALLY AND VERTICALLY. CALL OUT MIN. 3 |
| | FT. SETBACK FROM EDGE OF PROPOSED DRIVEWAY TO PROPERTY |
| | LINE. SHOW ANY WATER METERS, SANITARY CLEANOUTS, STORM |
| | INLETS ETC. IN VICINITY OF PROPOSED DRIVEWAY. DO NOT |
| | CONSTRUCT DRIVEWAY ON TOP OF WATER METERS, SANITARY |
| | CLEANOUTS, STORMWATER INLETS ETC. MAXIMUM DRIVEWAY |
| | WIDTHS AT RIGHT OF WAY SHALL NOT EXCEED 20 FT. PLUS TWO |
| | 3 FT. FLARES. |
| | |
| | CONSTRUCT DRIVEWAY APRON IN COMPLIANCE WITH WPB |
| | CONSTRUCTION STANDARD DETAIL GC-5 (WHEN DISTANCE |
| | BETWEEN CURB OR EDGE OF PAVEMENT IS 10 FT. OR GREATER), |
| | OR STANDARD DETAIL GC-6 (WHEN DISTANCE BETWEEN CURB OR |
| | EDGE OF PAVEMENT IS LESS THAN 10 FT.) CITY STANDARD |
| | DETAIL IS REQUIRED, SEE LINK BELOW: HTTPS://WWW.WPB.ORG |
| | /GOVERNMENT/ENGINEERING/ENGINEERING-STANDARDS-DETAILS |
| | |
| | |