| 2023-07-06 13:57:22 | FINAL ELEVATION CERTIFICATE | | | REVIEW COMMENTS | | | | | | 3RD REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) [NOT RESOLVED. REMOVE THE 1792 AND ENTER 2800 IN THE | | | SPACE. REMOVE THE NOTE ABOUT THE 2800 SQFT. THIS IS | | | EXPLAINED IN THE COMMENT SECTION OF SECTION D.] FOR | | | ITEM A8 C) ENTER THE TOTAL COVERAGE AREA OR RATED AREA | | | OF THE ENGINEERED OPENINGS WHICH IS EQUIVALENT TO THE | | | PERFORMACE THAT WOULD BE PROVIDED BY THAT NUMBER OF | | | SQUARE INCHES OF NON-ENGINEERED OPENINGS. THE FLOOD | | | VENT DETAIL ON THE ARCHITECTURAL PLANS SPECIFY (14) | | | SMART VENTS MODEL NUMBER 1540-520, WHICH HAVE A | | | CAPACITY OF 200 SQFT PER VENT. THE TOTAL WILL BE 14 X | | | 200 = 2800. THE CRAWL SPACE AREA IS 2771 SQFT. FEMA | | | TECHNICAL BULLETIN #1 SECTION 9.3.5 | | | | | | 2) RESOLVED. | | | | | | 6) RESOLVED. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-06-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-06-08 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-06-07 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2023-06-07 14:26:12 | FINAL ELEVATION CERTIFICATE | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FOR ITEM A8 C) ENTER THE TOTAL COVERAGE AREA OR | | | RATED AREA OF THE ENGINEERED OPENINGS WHICH IS | | | EQUIVALENT TO THE PERFORMACE THAT WOULD BE PROVIDED BY | | | THAT NUMBER OF SQUARE INCHES OF NON-ENGINEERED | | | OPENINGS. THE FLOOD VENT DETAIL ON THE ARCHITECTURAL | | | PLANS SPECIFY (14) SMART VENTS MODEL NUMBER 1540-520, | | | WHICH HAVE A CAPACITY OF 200 SQFT PER VENT. THE TOTAL | | | WILL BE 14 X 200 = 2800. THE CRAWL SPACE AREA IS 2771 | | | SQFT. FEMA TECHNICAL BULLETIN #1 SECTION 9.3.5 | | | | | | 2) THE PHOTOS THAT WERE SUBMITTED ONLY SHOW FLOOD VENTS | | | ON ONE WALL. PROVIDE PHOTOS THAT SHOW THE FLOOD VENTS | | | ON AT LEAST TWO OF THE ELEVATIONS. | | | | | | 6) THE PHOTOS NEED TO STATE "RIGHT SIDE VIEW" AND "LEFT | | | SIDE VIEW" PER INSTRUCTIONS. NOT SOUTH SIDE OR WEST | | | SIDE. FEMA ELEVATION CERTIFICATE INSTRUCTIONS | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-08-25 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2022-08-25 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-08-25 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2022-08-25 11:16:14 | | | | FINAL ELEVATION CERTIFICATE | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE NUMBER OF PERMANENT FLOOD OPENINGS LISTED FOR | | | ITEM A8(A) IS (9). ITEM A8(D) SPECIFIES THE VENTS AS | | | BEING ENGINEERED. THE FLOOD VENT DETAIL ON THE | | | ARCHITECTURAL PLANS SPECIFY (14) SMART VENTS MODEL | | | NUMBER 1540-520, WHICH HAVE A CAPACITY OF 200 SQFT PER | | | VENT. THE CRAWL SPACE AREA IS 2771 SQFT. NINE (9) OF | | | THESE VENTS ARE ONLY GOOD FOR 9 X 200 = 1800 SQFT. | | | ADDITIONAL VENTS ARE REQUIRED. FBC-R322.2.2 | | | | | | 2) SINCE THIS BUILDING HAS NO ATTACHED GARAGE THE BOXES | | | FOR A9 (D) SHOULD NOT BE MARKED. | | | | | | 3) SPECIFY THE ENGINEERED FLOOD VENTS THAT WERE USED IN | | | THE COMMENTS. | | | | | | 4) PROVIDE PHOTOS THAT SHOW THE FLOOD VENTS ON AT LEAST | | | TWO OF THE ELEVATIONS. | | | | | | 5) THE PHOTOS NEED TO BE DATED. | | | | | | 6) THE PHOTOS NEED TO STATE ?FRONT VIEW? ?REAR VIEW? | | | ??RIGHT SIDE VIEW? ?LEFT SIDE VIEW? PER INSTRUCTIONS. | | | | | | 7) SECTION ?D? THE BOX ?CHECK HERE IF ATTACHMENTS? | | | SHOULD BE CHECKED (FOR THE FLOOD VENT ENGINEERING) ? | | | SEE FEMA ELEVATION INSTRUCTIONS ?ITEMS A8B-D? | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-07-14 |
Time |
09:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-07-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-07-06 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-06-23 |
Time |
08:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-06-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-06-08 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-06-01 |
Time |
14:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-08-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-08-25 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-08-24 |
Time |
10:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-07-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-07-06 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-07-06 |
Time |
13:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-06-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-06-07 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-06-07 |
Time |
14:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-08-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-08-25 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-08-25 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2022-08-25 09:33:30 | SIGNATURES AND SEALS ON THE PAPER FINAL E.C. AND SURVEY | | | ARE GOOD. |
|
|