Plan Review Details - Permit 22081100
Plan Review Stops For Permit 22081100
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-10-22 Cont ID  
Sent By shill Date 2022-10-22 Time 16:13 Rev Time 0.00
Received By shill Date 2022-10-22 Time 16:13 Sent To  
Notes
2022-10-22 16:13:21CAP - EROSEBERRY

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-09-06 Cont ID  
Sent By shill Date 2022-09-06 Time 16:38 Rev Time 0.00
Received By shill Date 2022-09-06 Time 16:38 Sent To  
Notes
2022-09-06 16:39:52SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FBC EB 702.5, REVISE PLAN TO SHOW WHAT TYPE OF
 WINDOW IS BEING REPLACED. NOTE THAT THE WINDOWS MARKED
 AS "EGRESS" DO NOT MEET EGRESS REQUIREMENTS. FOR
 INSTANCE, OPENING 4 SHOWS A DIMENSIO OF 36.25X49.75 FOR
 A HORIZONTAL ROLLER WINDOW. IF THIS IS THE OPENING SIZE
 REVISE THE PLAN TO CLARIFY AND ALSO INCLUDE THE OVERALL
 DIMENSION AS THAT IS WHAT IS USED TO DETERMINE DESIGN
 PRESSURE REQUIREMENTS.
  
 2. FBC R 703.4, SUBMIT A FLASHING DETAIL.
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-10-22 Cont ID  
Sent By shill Date 2022-10-22 Time 16:13 Rev Time 0.00
Received By shill Date 2022-09-29 Time 11:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-09-06 Cont ID  
Sent By shill Date 2022-09-06 Time 16:40 Rev Time 0.00
Received By shill Date 2022-08-26 Time 09:59 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2022-09-06 Cont ID  
Sent By shill Date 2022-09-06 Time 16:40 Rev Time 0.00
Received By shill Date 2022-09-06 Time 16:39 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy