| Plan Review Stops For Permit 22081081 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2022-10-27 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-10-27 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-10-27 |
Time |
07:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2022-10-17 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-10-17 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-10-17 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2022-10-17 10:41:48 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. PLEASE ADDRESS THE SIGNATURE REVIEW COMMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-10-03 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-10-03 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-10-03 |
Time |
07:49 |
Sent To |
|
|
| Notes |
| 2022-10-03 11:38:37 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FS471, DOCUMENTS PREPARED BY AN ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. PLEASE UPLOAD A VALID ELECTRONICALLY | | | SIGNED DOCUMENT (STRUCTURAL CALCULATIONS FOR PANEL | | | ANCHORAGE) TO PROJECTDOX. | | | 2. FBC B 107.2.1. REVISE SUBMITTED STRUCTURAL | | | CALCULATIONS FOR PANEL ANCHORAGE DOCUMENT TO CORRECT | | | EXPOSURE CATEGORY. THE EXPOSURE CATEGORY FOR 411 SUMMA | | | ST. WEST PALM BEACH, FL 33405 IS EXPOSURE CATEGORY C. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-09-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-15 |
Time |
06:08 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-15 |
Time |
06:08 |
Sent To |
|
|
| Notes |
| 2022-09-15 06:09:47 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | PERMIT #22081081 BUILDING REVIEW FAILED. 411 SUMMA ST. | | | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL30343.07-R2 IS NOT RATED FOR USE IN ZONE 2 | | | OR ZONE 3 FOR STRUCTURES LOCATED IN EXPOSURE B, C, OR D | | | HAVE EITHER FLAT ROOF OR GABLE/HIP ROOF WITH MAX SLOPE | | | OF 12:12 WITH A MEAN ROOF HEIGHT 30 FEET OR LESS WIND | | | SPEED 170 MPH. PROVIDE SIGNED AND SEALED ENGINEERING | | | FOR USE OR SELECT A SYSTEM THAT MEETS THE ABOVE | | | CRITERIA. PROJECT LOCATED IN EXPOSURE C CATEGORY AREA. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX | | | | | | JONATHAN N. BROOKS JR. | | | BUILDING PLAN REVIEWER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENTIAL SERVICES | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-08-26 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-08-26 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-08-26 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2022-08-26 08:35:26 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL2569-R24 | | | IS NOT APPROVED FOR USE AS A SEAM TAPE IN METAL PANEL | | | INSTALLATION AS PER TABLE 1 PAGE #4. PROVIDE A COMPLETE | | | SET OF 2020 CODE VERSION PRODUCT APPROVALS/NOA'S FOR | | | THE PROPOSED ROOF UNDERLAYMENT (JOINT TAPE/STRIPS) TO | | | BE USED. INCLUDE COVER PAGE, EVALUATION REPORTS AND | | | INSTALLATION INSTRUCTIONS FOR SYSTEM USED. ALL | | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. OPTION | | | FL12328-R9 (NON-HVHZ) | | | 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL1654-R29 SYSTEM NO. W-209 DOES NOT MEET THE | | | MINIMUM ZONE 3 DESIGN PRESSURE REQUIREMENT OF -108.17 | | | FOR EXPOSURE CATEGORY C AREAS. PROVIDE SYSTEM THAT | | | MEETS OR EXCEEDS ALL DESIGN PRESSURE REQUIREMENTS FOR | | | EXPOSURE CATEGORY C/PROVIDE SIGNED AND SEALED | | | ENGINEERED NAILING CALCULATIONS WITH AN APPROVED | | | SYSTEM. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2022-10-27 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-10-27 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-10-19 |
Time |
08:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-10-17 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-10-17 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-10-06 |
Time |
07:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-10-03 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-10-03 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-09-27 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-09-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-15 |
Time |
06:09 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-06 |
Time |
07:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-08-26 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-08-26 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-08-25 |
Time |
07:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-10-27 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-10-27 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-10-27 |
Time |
07:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-10-17 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-10-17 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-10-17 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2022-10-17 10:42:45 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | SUBMITTED SIGNED AND SEALED STRUCTURAL CALCULATIONS FOR | | | PANEL ANCHORAGE CAN NOT BE VERIFIED IT APPEARS TO BE A | | | COPY OF A DIGITALLY SIGNED DOCUMENT. | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED | | | PLAN/DOCUMENT TO PROJECTDOX | | | PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO | | | LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH | | | BUILDING DEPRTMENT. | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6656. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-10-03 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-10-03 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-10-03 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2022-10-03 11:37:47 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | STRUCTURAL CALCULATIONS FOR PANEL ANCHORAGE NOT SIGNED | | | & SEALED. | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED | | | PLAN/DOCUMENT TO PROJECTDOX | | | PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO | | | LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH | | | BUILDING DEPRTMENT. | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6656. | | | |
|
|