Plan Review Details - Permit 22081069
Plan Review Stops For Permit 22081069
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-10-19 Cont ID  
Sent By cthroop Date 2022-10-19 Time 09:41 Rev Time 0.00
Received By cthroop Date 2022-10-19 Time 07:15 Sent To  
Notes
2022-10-19 09:45:511ST BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE: A SEPERATE PERMIT IS REQUIRED FOR THE ACCESSORY
 STRUCTURE.
 PRO-RATE VALUE AS FOLLOWS: MAIN DWELLING UNIT
 (MDU)-$115,380; ACCESSORY STRUCTURE-$16,620.
  
 NOTICE: SUBMIT MEP PLANS FOR REVIEW.
  
 1.PROVIDE A COPY OF THE MOST RECENT BOUNDARY LINE
 SURVEY.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3
 IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED BOUNDARY LINE SURVEY.
 FBC R401.3 SITE DRAINAGE
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD.
 LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
 FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6
 INCHES WITHIN THE FIRST 10 FEET.
  
 3. PROVIDE AN ENERGY SUBMITTAL RESIDENTIAL (RE)
 R401.2COMPLIANCE.
 SECTION R405 AND THE PROVISIONS OF SECTIONS R401
 THROUGH R404 LABELED MANDATORY.
  
 4. PROVIDE CURRENT PRODUCT APPROVALS OR NOA FOR
 PROPOSED HORIZONTAL SLIDER WINDOWS.
 PRODUCT APPROVALS INCLUDE THE COVER SHEET, EVALUATION
 REPORT AND INSTALLATION INSTRUCTIONS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 5.SMOKE ALARMS
 R314.2.2ALTERATIONS, REPAIRS AND ADDITIONS.
 WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC R314.
  
 6. PROVIDE LOCATION OF ATTIC ACCESS PER R807.1.7.
 R807.1.7 BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF
 CONSTRUCTION SHALL HAVE AN ATTIC ACCESS OPENING TO
 ATTIC AREAS THAT HAVE A VERTICAL HEIGHT OF 30 INCHES
 (762 MM) OR GREATER OVER AN AREA OF NOT LESS THAN 30
 SQUARE FEET (2.8 M2).
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-09-27 Cont ID  
Sent By fgiaquin Date 2022-09-27 Time 20:00 Rev Time 0.00
Received By fgiaquin Date 2022-09-26 Time 22:27 Sent To  
Notes
2022-09-27 20:00:48ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. NO ELECTRICAL DRAWINGS UPLOADED. COVERPAGE SHOWS E
 DRAWINGS. PLEASE UPLOAD DRAWINGS FOR REVIEW. FS
 471.003(2)(H); 471.025; WPB FBC 107.2.1, 107.3.5
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-805-6744
  

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2022-10-07 Cont ID  
Sent By amhamilt Date 2022-10-07 Time 10:59 Rev Time 0.00
Received By amhamilt Date 2022-10-07 Time 10:59 Sent To  
Notes
2022-10-07 11:01:00THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 PER HPB DECISION, "GLASS GARAGE DOOR TO HAVE TWO
 ADDITIONAL VERTICAL ELEMENTS ADDED TO MIMIC PANEL
 PATTERN OF ORIGINAL DOOR." PLEASE REVISE PLANS TO
 INCLUDE THIS PATTERN ON THE GARAGE DOOR.
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-10-19 Cont ID  
Sent By cthroop Date 2022-10-19 Time 09:58 Rev Time 0.00
Received By cthroop Date 2022-09-06 Time 07:33 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-10-19 Cont ID  
Sent By cthroop Date 2022-10-19 Time 07:16 Rev Time 0.00
Received By cthroop Date 2022-10-19 Time 07:16 Sent To  
Notes
2022-10-19 07:17:01IMPACT FEES
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-09-13 Cont ID  
Sent By medwards Date 2022-09-13 Time 17:24 Rev Time 0.00
Received By medwards Date 2022-09-13 Time 17:24 Sent To  
Notes
2022-09-13 17:29:16PROVIDE THE MECHANICAL DESIGN FO RTHIS PROJECT. FBC
 107.3.5
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-09-15 Cont ID  
Sent By rwbrown Date 2022-09-15 Time 08:48 Rev Time 0.00
Received By rwbrown Date 2022-09-15 Time 08:48 Sent To  
Notes
2022-09-15 08:49:461ST PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2017 WPB AMEND 107.3.5.3 (12) - PLEASE SUBMIT THE
 PLUMBING RISER FOR ALL NEW AND MODIFIED PLUMING DRAINS,
 WASTE AND VENTS.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2022-10-19 Cont ID  
Sent By cthroop Date 2022-10-19 Time 09:31 Rev Time 0.00
Received By cthroop Date 2022-10-19 Time 07:16 Sent To  
Notes
2022-10-19 09:32:40VALUE OF BOTH ROOFS INCLUDED ON PERMIT APP. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-10-19 Cont ID  
Sent By cthroop Date 2022-10-19 Time 09:41 Rev Time 0.00
Received By cthroop Date 2022-10-19 Time 07:16 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2022-10-07 Cont ID  
Sent By amhamilt Date 2022-10-07 Time 13:46 Rev Time 0.00
Received By amhamilt Date 2022-10-07 Time 13:46 Sent To  
Notes
2022-10-07 13:53:58THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 THE VALUE OF CONSTRUCTION EXCEEDS 50% OF THE
 IMPROVEMENT VALUE OF THE STRUCTURE, THEREFORE A
 SEPERATE LANDSCAPE PERMIT IS REQUIRED AND MUST BE
 SUBMITTED FOR ZONING APPROVAL TO MOVE FORWARD
  
 SEC 94-441 (B)
  
 ALL POOLS, MECHANICAL, ELECTRICAL, FENCES, SITE WALLS,
 DRIVEWAYS AND LANDSCAPE TO BE APPROVED UNDER A SEPARATE
 PERMIT.
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  