Plan Review Details - Permit 22080828
Plan Review Stops For Permit 22080828
Review Stop AD ADDRESSING
Rev No 4 Status P Date 2022-11-22 Cont ID  
Sent By cpuell Date 2022-11-22 Time 07:05 Rev Time 0.00
Received By cpuell Date 2022-11-22 Time 07:05 Sent To  
Notes
2022-11-22 07:06:53PER ALEXIS SANGELEER - GOOD AFTERNOON BILL,
  
 JUST WANTED TO INFORM YOU THE ACCESSORY STRUCTURE
 CANNOT BE RENTED OUT THE ZONING ONLY ALLOWS SINGLE
 FAMILY.
  
 ALEXIS SANGELEER
 ASSOCIATE PLANNER
  
 NO ADDITIONAL ADDRESS REQUIRED AT THIS TIME

Review Stop AD ADDRESSING
Rev No 3 Status F Date 2022-11-08 Cont ID  
Sent By cpuell Date 2022-11-08 Time 13:25 Rev Time 0.00
Received By cpuell Date 2022-11-08 Time 13:25 Sent To  
Notes
2022-11-08 13:25:47PLEASE CONTACT [email protected] OR CALL
 561-805-6659 ONCE ZONING APPROVES ADDITIONAL UNIT.

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2022-10-08 Cont ID  
Sent By cpuell Date 2022-10-08 Time 10:55 Rev Time 0.00
Received By cpuell Date 2022-10-08 Time 10:55 Sent To  
Notes
2022-10-08 10:58:09PLEASE CONTACT [email protected] OR CALL
 561-805-6659 ONCE ZONING APPROVES ADDITIONAL UNIT.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-08-29 Cont ID  
Sent By cpuell Date 2022-08-29 Time 16:33 Rev Time 0.00
Received By cpuell Date 2022-08-29 Time 16:33 Sent To  
Notes
2022-08-29 16:36:53AN ADDRESS WILL NEED TO BE ASSIGNED IF ZONING ALLOWED
 FOR A SECOND UNIT ON THE PARCEL. THE SURVEY DOES NOT
 SHOW THE LOCATION OF EITHER BUILDING, THE MAIN BUILDING
 IS BEING PERMITTED UNDER 22080613. ONCE ZONING APPROVES
 THE SECOND UNIT, PLEASE CONTACT [email protected]
 OR CALL 561-805-6659 TO BE ASSIGNED AN ADDRESS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-11-30 Cont ID  
Sent By cthroop Date 2022-11-30 Time 13:29 Rev Time 0.00
Received By cthroop Date 2022-11-30 Time 11:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-11-01 Cont ID  
Sent By cthroop Date 2022-11-01 Time 16:11 Rev Time 0.00
Received By cthroop Date 2022-11-01 Time 15:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-10-03 Cont ID  
Sent By cthroop Date 2022-10-03 Time 16:04 Rev Time 0.00
Received By cthroop Date 2022-09-15 Time 17:01 Sent To  
Notes
2022-10-03 16:08:011ST BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 1. PROVIDE AN ENERGY SUBMITTAL. RESIDENTIAL (RE)
 R401.2COMPLIANCE.
 PROJECTS SHALL COMPLY WITH ONE OF THE FOLLOWING:
 1.SECTIONS R401 THROUGH R404.
 2.SECTION R405 AND THE PROVISIONS OF SECTIONS R401
 THROUGH R404 LABELED MANDATORY.
  
 2. PROVIDE THE ICC-ES REPORT FOR THE ICYNENE SPRAY FOAM
 INSULATION.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2023-01-05 Cont ID  
Sent By mpeterso Date 2023-01-05 Time 16:07 Rev Time 0.00
Received By mpeterso Date 2023-01-05 Time 16:05 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2023-01-05 Cont ID  
Sent By mpeterso Date 2023-01-05 Time 13:57 Rev Time 0.00
Received By mpeterso Date 2023-01-05 Time 13:57 Sent To  
Notes
2023-01-05 13:59:20NO ELECTRIC DRAWING WAS SUBMITTED. IT APPEARS ANOTHER
 PLUMBING PLAN WAS SUBMITTED IN PLACE OF AN ELECTRIC
 PLAN.

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2022-12-15 Cont ID  
Sent By mpeterso Date 2022-12-15 Time 08:46 Rev Time 0.00
Received By mpeterso Date 2022-12-15 Time 08:38 Sent To  
Notes
2022-12-15 09:03:52ELECTRIC REVIEW FAILED
 1) PREVIOUS COMMENT CONCERNING COMPLIANCE WITH REDUCED
 AMPACITY OF 83% NOT ALLOWED FOR TWO ELECTRIC PANELS
 FEDDING THE SAME DWELLING IS NOT ADDRESSED.
 2) GROUNDING ELECTRODE SYSTEM REQUIRED FOR GUEST HOUSE
 PANEL NOT SHOWN. 250.32
  
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2022-11-28 Cont ID  
Sent By mpeterso Date 2022-11-28 Time 13:34 Rev Time 0.00
Received By mpeterso Date 2022-11-28 Time 12:51 Sent To  
Notes
2022-11-28 13:35:31ELECTRIC REVIEW FAILED
 1) ELECTRIC RISER DIAGRAM DETAILS (2) ELECTRIC PANELS
 FOR WHAT IS ASSUMED TO BE THE MAIN HOUSE. THESE PANELS
 ARE DETAILED AS BEING FED WITH 2/0 CU CONDUCTORS. 2/0
 CU CONDUCTORS FEEDING ONLY PART OF THE MAIN HOUSE ARE
 NOT PERMITTED TO BE DE-RATED TO 83%. ONLY CONDUCTORS
 SUPPLYING THE ENTIRE LOAD ASSOCIATED WITH A DWELLING IS
 PERMITTED TO BE DE-RATED TO 83%. IN ADDITION, ALL 6 OF
 THESE CONDUCTORS ARE DETAILED AS BEING IN THE SAME
 CONDUIT WHICH WOULD REQUIRE FURTHER DERATING AS PER NEC
 310.15(B)(3). PLEASE CORRECT AS APPLICABLE FOR CODE
 COMPLIANCE
 2) THE ELECTRIC RISER DIAGRAM DOES NOT DETAIL SIZE OF
 SERVICE OR ANY MAIN DISCONNECTS. PLEASE DETAIL SERVICE
 SIZE AND ALL MAIN OVERCURRENT PROTECTION AS REQUIRED
 PER NEC 215.5 AND NEC 240.4
 3) PLEASE DETAIL ALL MAIN DISCONNECTS AS GROUPED IN ONE
 LOCATION AND MARKED TO INDICATE THE LOAD SERVED AS PER
 NEC 230.72
 4) PLEASE DETAIL GROUNDING ELECTRODE CONNECTIONS IN
 PROPER LOCATIONS NOT CONNECTED TO CONDUITS. NEC215.5
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2022-10-19 Cont ID  
Sent By mpeterso Date 2022-10-19 Time 12:12 Rev Time 0.00
Received By mpeterso Date 2022-10-19 Time 12:12 Sent To  
Notes
2022-10-19 12:24:47ELECTRIC REVIEW FAILED
  
 1) PLEASE LOCATE ALL ELECTRIC EQIPMENT ON A SITE PLAN
 AS THE SERVICE ORIGINATES AT A SEPARATE STRUCURE AS
 THIS INFORMATION IS REQUIRED TO DO A COMPLETE
 ELECTRICAL REVIEW. FBC 107.2
 2) RISER DIAGRAMS MAIN DISCONNECTS NOT GROUPED AS
 REQUIRED PER NEC 230.72. PLEASE CORRECT AS APPLICABLE
 3) PLEASE SEE ZONING REVIEW AS THIS STRUCTURE APPEARS
 TO BE PROHIBITED. FBC 107.2
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-09-14 Cont ID  
Sent By mpeterso Date 2022-09-14 Time 15:00 Rev Time 0.00
Received By mpeterso Date 2022-09-14 Time 15:00 Sent To  
Notes
2022-09-14 15:12:00ELECTRIC REVIEW FAILED
 1)PLEASE PROVIDE ALL ELECTRICAL EQUIPMENT LOCATIONS
 DETAILED ON ELECTRIC RISER. FBC 107.2
 2) PLEASE DETAIL NEC CLEARANCE REQUIREMENTS FOR
 INTERIOR ELECTRIC PANEL. NEC 110.26
 3) PLEASE DETAIL THE REQUIRED OUTDOOR RECEPTACLES AS
 PER NEC 210.52
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2023-01-05 Cont ID  
Sent By lmarchan Date 2023-01-05 Time 16:13 Rev Time 0.00
Received By lmarchan Date 2023-01-05 Time 16:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2023-01-05 Cont ID  
Sent By mpeterso Date 2023-01-05 Time 14:21 Rev Time 0.00
Received By mpeterso Date 2022-12-27 Time 07:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-12-15 Cont ID  
Sent By mpeterso Date 2022-12-15 Time 09:07 Rev Time 0.00
Received By mpeterso Date 2022-12-05 Time 08:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-11-30 Cont ID  
Sent By cthroop Date 2022-11-30 Time 13:30 Rev Time 0.00
Received By cthroop Date 2022-11-03 Time 07:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-11-01 Cont ID  
Sent By cthroop Date 2022-11-01 Time 16:12 Rev Time 0.00
Received By cthroop Date 2022-10-05 Time 07:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-10-03 Cont ID  
Sent By cthroop Date 2022-10-03 Time 16:08 Rev Time 0.00
Received By cthroop Date 2022-08-22 Time 08:16 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2023-01-12 Cont ID  
Sent By lmarchan Date 2023-01-12 Time 12:56 Rev Time 0.00
Received By lmarchan Date 2023-01-05 Time 15:58 Sent To  
Notes
2023-01-12 12:56:04NO IMPACT FEES DUE. LEM
2023-01-05 15:58:531/5/23 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-09-15 Cont ID  
Sent By cthroop Date 2022-09-15 Time 17:04 Rev Time 0.00
Received By cthroop Date 2022-09-15 Time 17:02 Sent To  
Notes
2022-09-15 17:05:34IMPACT FEES
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2022-11-14 Cont ID  
Sent By medwards Date 2022-11-14 Time 17:28 Rev Time 0.00
Received By medwards Date 2022-11-14 Time 17:28 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2022-10-17 Cont ID  
Sent By medwards Date 2022-10-17 Time 16:19 Rev Time 0.00
Received By medwards Date 2022-10-17 Time 16:19 Sent To  
Notes
2022-10-17 16:27:13THE ENERGY CALCULATIONS SUBMITTED INDICATE THIS TO BE
 THE WORST CASE. THIS SINGLE BUILDING DOES NOT MEET THE
 EXCEPTIONS OF FEC R405.4.2.1 PLEASE SUBMIT AN ENERGY
 CALCULATION THAT MEETS FEC R405.4.2.1 AND IF THIS
 CHANGES THE MECHANICAL EQUIPMENT SIZE PLEASE PROVIDE A
 NEW MECHANICAL EQUIPMENT SIZING CALCULATION.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-08-31 Cont ID  
Sent By medwards Date 2022-08-31 Time 07:57 Rev Time 0.00
Received By medwards Date 2022-08-31 Time 07:56 Sent To  
Notes
2022-08-31 08:02:061) PROVIDE THE ENERGY CALCULATIONS. FEC R401
  
 2) PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FEC R403.7
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-11-04 Cont ID  
Sent By rwbrown Date 2022-11-04 Time 09:03 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-10-06 Cont ID  
Sent By rwbrown Date 2022-10-06 Time 14:52 Rev Time 0.00
Received By rwbrown Date 2022-10-06 Time 14:52 Sent To  
Notes
2022-10-06 14:55:161ST PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
  
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2017 WPB AMEND 107.3.5.3 (12) - THE RISER DIAGRAM
 AND THE FLOOR PLAN DO NOT MATCH. THE RISER SHOWS A TUB
 AND THE FLOOR PLAN DOES NOT.
  
 2. 2020 FRC P3201.7 - THE MINIMUM PIPE SIZE FOR THE
 LAUNDRY TRAP IS 2", NOT 1 1/2".
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-08-23 Cont ID  
Sent By rwbrown Date 2022-08-23 Time 07:19 Rev Time 0.00
Received By rwbrown Date 2022-08-23 Time 07:19 Sent To  
Notes
2022-08-23 07:20:031ST PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2017 WPB AMEND 107.3.5.3 (12) - PLEASE INCLUDE A
 PLUMBING RISER DIAGRAM
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2022-11-01 Cont ID  
Sent By cthroop Date 2022-11-01 Time 16:11 Rev Time 0.00
Received By cthroop Date 2022-11-01 Time 15:14 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-10-03 Cont ID  
Sent By cthroop Date 2022-10-03 Time 14:48 Rev Time 0.00
Received By cthroop Date 2022-09-15 Time 17:02 Sent To  
Notes
2022-10-03 14:56:461ST ROOFING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 REFERENCE FL 7473-R9 FOR THE FOLLOWING COMMENT:
  
 1. DESIGNER SHALL SELECT MEANS OF ATTACHMENT. IF
 ADHESIVE SET IS SELECTED, PROVIDE PRODUCT APPROVALS FOR
 TILE ADHESIVE.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2. PROVIDE PRODUCT APPROVALS FOR SECONDARY WATER
 BARRIER PER FBC R905.1.1.
 UNDERLAYMENT FOR ROOF SLOPES 2:12 AND GREATER SHALL
 CONFORM TO THE APPLICABLE STANDARDS??? AND SHALL BE
 APPLIED AND ATTACHED IN ACCORDANCE WITH SECTION
 R905.1.1.1, R905.1.1.2 OR R905.1.1.3, AS APPLICABLE.
 PROVIDE THE FL PRODUCT APPROVALS OR MIAMI-DADE NOA FOR
 THE PROPOSED ROOFING UNDERLAYMENT TO BE INSTALLED.
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 NOTE: NOA???S DO NOT HAVE COVER SHEETS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 3. PROVIDE PRODUCT APPROVALS FOR HIP AND RIDGE TILE.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 6 Status P Date 2023-01-05 Cont ID  
Sent By mpeterso Date 2023-01-05 Time 16:08 Rev Time 0.00
Received By mpeterso Date 2023-01-05 Time 16:08 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2023-01-05 Cont ID  
Sent By mpeterso Date 2023-01-05 Time 14:21 Rev Time 0.00
Received By mpeterso Date 2023-01-05 Time 14:21 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-12-15 Cont ID  
Sent By mpeterso Date 2022-12-15 Time 09:07 Rev Time 0.00
Received By mpeterso Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-11-30 Cont ID  
Sent By cthroop Date 2022-11-30 Time 13:29 Rev Time 0.00
Received By cthroop Date 2022-11-30 Time 11:28 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-10-19 Cont ID  
Sent By mpeterso Date 2022-10-19 Time 12:29 Rev Time 0.00
Received By mpeterso Date 2022-10-19 Time 12:29 Sent To  
Notes
2022-10-19 12:32:12PLANS IN SIGNATURE FILE PASSED REVIEW
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-10-03 Cont ID  
Sent By cthroop Date 2022-10-03 Time 08:20 Rev Time 0.00
Received By cthroop Date 2022-09-15 Time 17:02 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2022-11-18 Cont ID  
Sent By asangele Date 2022-11-18 Time 10:23 Rev Time 0.00
Received By asangele Date 2022-11-18 Time 10:23 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2022-10-13 Cont ID  
Sent By asangele Date 2022-10-13 Time 14:20 Rev Time 0.00
Received By asangele Date 2022-10-13 Time 14:20 Sent To  
Notes
2022-10-13 14:25:2710/13/2022
 FAIL
  
 REPEAT COMMENT
  
  
 IBIS IS ONLY ZONED SINGLE FAMILY THEREFORE YOU CANNOT
 CREATE A SECOND DWELLING UNIT ON THE PROPERTY.
 SHEET 007 MECHANICAL AND 003 FOUNDATION PLAN ARE
 SHOWING A FULL FUNCTIONAL KITCHEN.
  
  
 ALEXIS SANGELEER
 ASSOCIATE PLANNER
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2022-08-26 Cont ID  
Sent By asangele Date 2022-08-26 Time 14:54 Rev Time 0.00
Received By asangele Date 2022-08-26 Time 14:53 Sent To  
Notes
2022-08-26 15:01:458/26/2022
 FAILED
  
 PLEASE PROVIDE BUILDING HEIGHT ELVATION OF ACCESORY
 STRUCTURE CANNOT EXCEED 25FT
  
 IBIS IS ONLY ZONED SINGLE FAMILY THEREFORE YOU CANNOT
 CREATE A SECOND DWELLING UNIT ON THE PROPERTY.
  
  
 ALEXIS SANGELEER
 ASSOCIATE PLANNER
 [email protected]