Plan Review Details - Permit 22080820
Plan Review Stops For Permit 22080820
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-08-19 Cont ID  
Sent By cpuell Date 2022-08-19 Time 09:50 Rev Time 0.00
Received By cpuell Date 2022-08-19 Time 09:50 Sent To  
Notes
2022-08-19 09:58:33WORK TO BE DONE ON TWO SEPARATE BUILDINGS ON THE
 PARCEL, WITH THE ADDRESSES OF 432 25TH ST (EAST BLDG)
 AND 434 25TH ST (WEST BLDG), UPDATED PERMIT DESCRIPTION
 TO INCLUDE BOTH BUILDINGS.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2022-12-07 Cont ID  
Sent By rmcphers Date 2022-12-07 Time 16:58 Rev Time 0.00
Received By rmcphers Date 2022-12-07 Time 16:58 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-10-06 Cont ID  
Sent By rmcphers Date 2022-10-06 Time 08:49 Rev Time 0.00
Received By rmcphers Date 2022-10-05 Time 13:56 Sent To  
Notes
2022-10-06 08:48:56PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2023-01-26 Cont ID  
Sent By rmcphers Date 2023-01-26 Time 13:11 Rev Time 0.00
Received By rmcphers Date 2023-01-26 Time 13:11 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2023-01-12 Cont ID  
Sent By rmcphers Date 2023-01-12 Time 13:50 Rev Time 0.00
Received By rmcphers Date 2023-01-12 Time 13:04 Sent To  
Notes
2023-01-12 13:11:07RENOVATION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE WIND DESIGN DATA USED (WIND SPEED,
 RISK CATEGORY, EXPOSURE, ETC.) FOR WIND DESIGN - SEE
 FBC 1603.1.4
  
 2) DOOR SIZE HAS NOT CHANGED ON THE DOOR SCHEDULE -
 PIVOT DOOR PRODUCT APPROVAL SEE PAGE 3 OF 11 (NOTE:
 DOOR CANNOT BE USED AS AN EGRESS DOOR WHEN THE DOOR
 LEAF WIDTH IS MORE THAN 48") -- THE 6 FOOT WIDE ENTRY
 DOOR SHOWN DOES NOT COMPLY WITH FBC 1010.1.1 SIZE OF
 DOORS. THE MAXIMUM WIDTH OF A SWINGING DOOR LEAF SHALL
 BE 48 INCHES (1219 MM) NOMINAL
  
 3) SHOW THE OCCUPANCY CLASSIFICATION ON THE DRAWINGS AS
 (S1) OR (S2) - - PLEASE SHOW THE MAIN "USE" FOR EACH
 BUILDING ( RESTAURANT, PROFESSIONAL OFFICES, STORAGE
 (WHAT MATERIALS OF STORAGE), RETAIL OR WHOLESALE STORE
 ETC.) - A WAREHOUSE WOULD BE A STORAGE AREA PLEASE SEE
 FBC SECTION 311 AND SHOW THE OCCUPANCY CLASSIFICATION
 AS S1 OR S2 - THE OCCUPANCY CLASSIFICATION NEEDS TO BE
 DETERMINED - FBC 302.1 OCCUPANCY CLASSIFICATION.
 OCCUPANCY CLASSIFICATION IS THE FORMAL DESIGNATION OF
 THE PRIMARY PURPOSE OF THE BUILDING, STRUCTURE OR
 PORTION THEREOF. STRUCTURES SHALL BE CLASSIFIED INTO
 ONE OR MORE OF THE OCCUPANCY GROUPS LISTED IN THIS
 SECTION BASED ON THE NATURE OF THE HAZARDS AND RISKS TO
 BUILDING OCCUPANTS GENERALLY ASSOCIATED WITH THE
 INTENDED PURPOSE OF THE BUILDING OR STRUCTURE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-12-08 Cont ID  
Sent By rmcphers Date 2022-12-08 Time 08:53 Rev Time 0.00
Received By rmcphers Date 2022-12-08 Time 08:29 Sent To  
Notes
2022-12-07 16:51:06RENOVATION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) THE PRODUCT APPROVALS FOR THE 8000 ALUMINUM WINDOW
 WALL AND THE PIVOT DOOR ARE NOT COMPLETE (FRONT PAGES
 AND THE INSTALLATION INSTRUCTIONS) - PLEASE PROVIDE
 COMPLETE (FRONT PAGES AND THE INSTALLATION
 INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE PRODUCT
 APPROVALS FOR THE EXTERIOR WINDOWS AND DOORS. ALL
 PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED
 APPROVED BY THE DESIGNER OF RECORD OR BE SHOWN ON THE
 PLANS BY PRODUCT APPROVAL NUMBER _ FBC WPB 107.3.4
  
 2) PLEASE SHOW THE WIND DESIGN DATA USED FOR WIND
 DESIGN PER FBC 1603.1.4
  
 3) PIVOT DOOR PRODUCT APPROVAL SEE PAGE 3 OF 11 (NOTE:
 DOOR CANNOT BE USED AS AN EGRESS DOOR WHEN THE DOOR
 LEAF WIDTH IS MORE THAN 48") -- THE 6 FOOT WIDE ENTRY
 DOOR SHOWN DOES NOT COMPLY WITH FBC 1010.1.1 SIZE OF
 DOORS. THE MAXIMUM WIDTH OF A SWINGING DOOR LEAF SHALL
 BE 48 INCHES (1219 MM) NOMINAL
  
 4) PLEASE SHOW THE MAIN "USE" FOR EACH BUILDING (
 RESTAURANT, PROFESSIONAL OFFICES, STORAGE (WHAT
 MATERIALS OF STORAGE), RETAIL OR WHOLESALE STORE ETC.)
 - A WAREHOUSE WOULD BE A STORAGE AREA PLEASE SEE FBC
 SECTION 311 AND SHOW THE OCCUPANCY CLASSIFICATION AS S1
 OR S2 - THE OCCUPANCY CLASSIFICATION NEEDS TO BE
 DETERMINED - FBC 302.1 OCCUPANCY CLASSIFICATION.
 OCCUPANCY CLASSIFICATION IS THE FORMAL DESIGNATION OF
 THE PRIMARY PURPOSE OF THE BUILDING, STRUCTURE OR
 PORTION THEREOF. STRUCTURES SHALL BE CLASSIFIED INTO
 ONE OR MORE OF THE OCCUPANCY GROUPS LISTED IN THIS
 SECTION BASED ON THE NATURE OF THE HAZARDS AND RISKS TO
 BUILDING OCCUPANTS GENERALLY ASSOCIATED WITH THE
 INTENDED PURPOSE OF THE BUILDING OR STRUCTURE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-10-06 Cont ID  
Sent By rmcphers Date 2022-10-06 Time 08:49 Rev Time 0.00
Received By rmcphers Date 2022-10-05 Time 13:56 Sent To  
Notes
2022-10-06 08:48:00RENOVATION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS AND DOORS.
 ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED
 APPROVED BY THE DESIGNER OF RECORD OR BE SHOWN ON THE
 PLANS BY PRODUCT APPROVAL NUMBER _ FBC WPB 107.3.4
  
 2) THE OCCUPANT LOAD SHOWN ON DRAWING CVR UNDER
 "OCCUPANCY LOADS" SHOWS THE INCORRECT NUMBER OF
 OCCUPANTS FOR MERCANTILE - SEE FBC TABLE 1004.5
  
 3) PLEASE SHOW THE OCCUPANT LOAD FOR EACH BUILDING
 SEPARATELY.
  
 4) PLEASE SHOW THE SQUARE FOOTAGE FOR EACH BUILDING
 SEPARATELY.
  
 5) PLEASE SHOW THE WALL LOCATION DIMENSIONS FOR ALL
 RESTROOM AND OFFICE WALLS.
  
 6) PLEASE SHOW THE WIND DESIGN DATA USED FOR WIND
 DESIGN PER FBC 1603.1.4
  
 7) THE 6 FOOT WIDE ENTRY DOOR SHOWN DOES NOT COMPLY
 WITH FBC 1010.1.1 SIZE OF DOORS. THE MAXIMUM WIDTH OF A
 SWINGING DOOR LEAF SHALL BE 48 INCHES (1219 MM)
 NOMINAL.
  
 8) PLEASE SHOW THE RAMP SLOPE - FBC 405.2 SLOPE. RAMP
 RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12.
  
 9) PLEASE SHOW THE STEEL COLUMN CONNECTION TO THE ADDED
 TIEBEAM.
  
 10) PLEASE SHOW THE RESTROOM WALL FINISH - FBC 1210.2.2
 WALLS AND PARTITIONS.
 WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE
 SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH,
 HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS
 THAN 4 FEET (1219 MM) ABOVE THE FLOOR,( DRYWALL IS NOT
 CONSIDERED A HARD SURFACE)
  
 11) ACCESSIBLE RESTROOM = PLEASE SHOW THE TOILET GRAB
 BAR MAXIMUM HEIGHT TO THE TOP OF THE GRIPPING SURFACE -
 FBC A 609.4 POSITION OF GRAB BARS.
 GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION,
 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM)
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF
 THE GRIPPING SURFACE,
  
 12) ACCESSIBLE RESTROOM = PLEASE USE THE WORDS
 "REFLECTING SURFACE" WHEN REFERRING TO THE MIRROR
 LOCATION - FBC 603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
  
 13) SEPARATE PERMITS ARE REQUIRED FOR SEPARATE
 BUILDINGS.
  
 14) ALL SIGNED AND SEALED DRAWINGS NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 PROJECTDOX - SIGNED AND SEALED DRAWINGS IN PROJECTDOX
 NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED
 IN ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2023-02-02 Cont ID  
Sent By mpeterso Date 2023-02-02 Time 08:51 Rev Time 0.00
Received By mpeterso Date 2023-02-02 Time 08:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2023-01-20 Cont ID  
Sent By mpeterso Date 2023-01-20 Time 13:08 Rev Time 0.00
Received By mpeterso Date 2023-01-20 Time 13:08 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-12-13 Cont ID  
Sent By fgiaquin Date 2022-12-13 Time 18:39 Rev Time 0.00
Received By fgiaquin Date 2022-12-12 Time 22:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-09-24 Cont ID  
Sent By fgiaquin Date 2022-09-24 Time 19:53 Rev Time 0.00
Received By fgiaquin Date 2022-09-24 Time 17:56 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2023-01-26 Cont ID  
Sent By pleduc Date 2023-01-26 Time   Rev Time 0.00
Received By pleduc Date 2023-01-26 Time 15:22 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2023-01-05 Cont ID  
Sent By pleduc Date 2023-01-05 Time   Rev Time 0.00
Received By pleduc Date 2023-01-04 Time 10:26 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-11-22 Cont ID  
Sent By pleduc Date 2022-11-22 Time   Rev Time 0.00
Received By pleduc Date 2022-11-22 Time 10:55 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-08-24 Cont ID  
Sent By pleduc Date 2022-08-24 Time   Rev Time 0.00
Received By pleduc Date 2022-08-22 Time 13:40 Sent To  
Notes
2022-08-22 14:00:04THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) SHEET A 1.2 - THERE IS AN INDICATION OF A MERCANTILE
 OCCUPANCY; HOWEVER, THERE IS ALSO AN INDICATION IN BLDG
 434, OF A NEW STORAGE AREA THAT IS SEPARATED BY A
 NONRATED NON ACCESSIBLE WALL & WINDOW.
  
 A STORAGE OCCUPACNY IS NOT THE SAME OCCUPANCY
 CLASSIFICATION AS MERCANTILE.
  
 PER NFPA 101 CH 6, TABLE 6.1.14.4.1, A 2 HOUR FIRE
 SEPARATION IS REQUIRED.
  
 PLEASE REVIEW AND CORRECT OR JUSTIFIY WITH SPECIFIC
 DETAILS AND NARRATIVE AND FIRE CODE REFERENCES.
  
  
 1A) SHOULD THIS BE CONSIDERED AS A MIXED NON-SEPARATED
 OCCUPANCY CLASSIFICATION PLEASE REVIEW AND CORRECT AS
 APPLICABLE.
  
  
  
 2) ON REVIEW OF THE ABOVE COMMENTS, A STORAGE OCCUPANCY
 NON-SEOARATED OR STAND ALONE SHALL HAVE THE HAZARD OF
 CONTENTS REVIEWED FOR FIRE RATED SEPARATION PURPOSES.
  
 PER NFPA 101
  
 6.2 HAZARD OF CONTENTS
 6.2.1 GENERAL.
 6.2.1.1 FOR THE PURPOSE OF THIS CODE, THE HAZARD OF
 CONTENTS SHALL BE
 THE RELATIVE DANGER OF THE START AND SPREAD OF FIRE,
 THE DANGER OF SMOKE
 OR GASES GENERATED, AND THE DANGER OF EXPLOSION OR
 OTHER OCCURRENCE
 POTENTIALLY ENDANGERING THE LIVES AND SAFETY OF THE
 OCCUPANTS OF THE
 BUILDING OR STRUCTURE
  
 6.2.1.2 HAZARD OF CONTENTS SHALL BE CLASSIFIED BY THE
 REGISTERED DESIGN
 PROFESSIONAL (RDP) OR OWNER AND SUBMITTED TO THE
 AUTHORITY HAVING
 JURISDICTION FOR REVIEW AND APPROVAL ON THE BASIS OF
 THE CHARACTER OF THE
 CONTENTS AND THE PROCESSES OR OPERATIONS CONDUCTED IN
 THE BUILDING OR
 STRUCTURE.
  
 6.2.1.3* FOR THE PURPOSE OF THIS CODE, WHERE DIFFERENT
 DEGREES OF HAZARD
 OF CONTENTS EXIST IN DIFFERENT PARTS OF A BUILDING OR
 STRUCTURE, THE MOST
 HAZARDOUS SHALL GOVERN THE CLASSIFICATION, UNLESS
 HAZARDOUS AREAS ARE
 SEPARATED OR PROTECTED AS SPECIFIED IN SECTION 8.7 AND
 THE APPLICABLE
 SECTIONS OF CHAPTERS 11 THROUGH 43
  
 6.2.2 CLASSIFICATION OF HAZARD OF CONTENTS.
 6.2.2.1* GENERAL. THE HAZARD OF CONTENTS OF ANY
 BUILDING OR STRUCTURE
 SHALL BE CLASSIFIED AS LOW, ORDINARY, OR HIGH IN
 ACCORDANCE WITH 6.2.2.2,
 6.2.2.3, AND 6.2.2.4
  
 PLEASE PROVIDE DETAILS FO THE PROPOSED
 PRODUCT/COMMODITY BEING STORED.
  
  
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2023-03-01 Cont ID  
Sent By medwards Date 2023-03-01 Time 11:09 Rev Time 0.00
Received By medwards Date 2023-02-27 Time 13:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2023-02-14 Cont ID  
Sent By medwards Date 2023-02-14 Time 16:01 Rev Time 0.00
Received By medwards Date 2023-02-10 Time 15:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-02-09 Cont ID  
Sent By asangele Date 2023-02-09 Time 17:05 Rev Time 0.00
Received By asangele Date 2023-02-09 Time 17:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-01-20 Cont ID  
Sent By mpeterso Date 2023-01-20 Time 13:09 Rev Time 0.00
Received By mpeterso Date 2023-01-03 Time 13:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-12-19 Cont ID  
Sent By lmarchan Date 2022-12-19 Time 16:03 Rev Time 0.00
Received By lmarchan Date 2022-11-21 Time 08:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-10-06 Cont ID  
Sent By rmcphers Date 2022-10-06 Time 09:03 Rev Time 0.00
Received By rmcphers Date 2022-08-19 Time 09:02 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2023-01-26 Cont ID  
Sent By rmcphers Date 2022-10-06 Time 08:50 Rev Time 0.00
Received By rmcphers Date 2022-10-06 Time 08:50 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2023-03-01 Cont ID  
Sent By medwards Date 2023-03-01 Time 11:09 Rev Time 0.00
Received By medwards Date 2023-03-01 Time 11:09 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2023-02-14 Cont ID  
Sent By medwards Date 2023-02-14 Time 16:00 Rev Time 0.00
Received By medwards Date 2023-02-14 Time 16:00 Sent To  
Notes
2023-02-14 16:00:501ST REVIEW FMC
 PERMIT: 22080820
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE ENERGY CALCULATIONS FOR THESE WAREHOUSES DO NOT
 REFLECT WHAT IS SHOWN ON THE M-1 SHEET. THE UNIT 432
 HAS AN A/C LOAD OF 41,932 BUT THE DRAWING INDICATES 2 5
 TON UNITS. EXPLAIN WHY THE 2 5 TON UNITS.
 FEC C403.2.2
  
 2) UNIT 434 ENERGY CALC CALLS FOR 41,683 OF COOLING BUT
 THE M-1 DRAWING INDICATES 2 3-TON UNITS. EXPLAIN WHY
 THE 2 3 - TON UNITS. FEC C403.2.2
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2023-01-30 Cont ID  
Sent By medwards Date 2023-01-30 Time 12:46 Rev Time 0.00
Received By medwards Date 2023-01-30 Time 12:42 Sent To  
Notes
2023-01-30 12:46:39PLEASE SUBMIT THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS ASKED FOR IN PREVIOUS REVIEWS. FEC
 C403.2.1
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2023-01-17 Cont ID  
Sent By medwards Date 2023-01-17 Time 07:02 Rev Time 0.00
Received By medwards Date 2023-01-17 Time 07:01 Sent To  
Notes
2023-01-17 07:02:34STILL MISSING THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2022-12-13 Cont ID  
Sent By medwards Date 2022-12-13 Time 16:33 Rev Time 0.00
Received By medwards Date 2022-12-13 Time 16:33 Sent To  
Notes
2022-12-13 16:33:532ND REVIEW FMC
 PERMIT: 22080820
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE MECHANICAL EQUIPMENT SIZING CALCULATIONS ARE
 MISSING. THE REFERENCED NEW INFORMATION ON SHEET M-1 IS
 THE OUTDOOR AIR CALCULATIONS.
  
 2) THE ENERGY CALCULATIONS DO NOT SHOW THE DOORS.
 PLEASE PROVIDE ENERGY CALCULATIONS AND MECHANICAL
 EQUIPMENT SIZING CALCULATIONS THAT INCLUDE THE DOORS.
 FBC 107.3.5
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-09-08 Cont ID  
Sent By medwards Date 2022-09-08 Time 17:26 Rev Time 0.00
Received By medwards Date 2022-09-08 Time 17:26 Sent To  
Notes
2022-09-08 17:26:161ST REVIEW FMC
 PERMIT: 22080820
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) OUR RECORDS INDICATE THIS ADDRESS IS A WAREHOUSE.
 PLEASE SHOW THIS AS A CHANGE OF USE AND OCCUPANCY. FBC
 107.3.5
  
 2) PROVIDE THE ENERGY CALCULATIONS FOR THIS PROJECT.
 FEC C402.1
  
 3) PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS
 FOR THIS PROJECT. FEC C403.2.1
  
 4) PROVIDE THE OUTDOOR AIR CALCULATIONS FOR EACH USE OF
 SPACE FOR THIS PROJECT. FMC 403.3.1.1 AND TABLE
 403.3.1.1
  
 5) SHOW THE BATHROOM EXHAUST FAN TERMINATION LOCATIONS.
 FMC 501.3
  
 6) SHOW THE ANCHORING DETAILS FOR THE CONDENSING UNITS
 AND SHOW THE PROPERTY LINES. FBC 105.3
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 5 Status P Date 2023-02-13 Cont ID  
Sent By ccole Date 2023-02-13 Time 11:02 Rev Time 0.00
Received By ccole Date 2023-02-13 Time 10:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2023-01-30 Cont ID  
Sent By jesmith Date 2023-01-30 Time 11:19 Rev Time 0.00
Received By jesmith Date 2023-01-30 Time 11:07 Sent To  
Notes
2023-01-30 11:19:1322080820 432 25TH ST
  
 PLUMBING COMMENTS: UNIT 432 ONLY IS REVIEWED FOR
 COMPLIANCE IN ACCORDANCE WITH WPB FBC 107.3.5.1.3
  
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 PLEASE NOTE: PER ENGINEER'S RESPONSE NARRATIVE DATED
 10/12/2022 AND UPLOADED 11/17/2022, THE WATER SERVICE
 IS EXISTING.
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2023-01-09 Cont ID  
Sent By jesmith Date 2023-01-09 Time 11:37 Rev Time 0.00
Received By jesmith Date   Time   Sent To  
Notes
2023-01-09 11:37:5122080820 432 25TH ST
  
 PLUMBING COMMENTS: UNIT 432 ONLY IS REVIEWED FOR
 COMPLIANCE IN ACCORDANCE WITH WPB FBC 107.3.5.1.3
  
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 PLEASE NOTE: PER ENGINEER???S RESPONSE NARRATIVE DATED
 10/12/2022 AND UPLOADED 11/17/2022, THE WATER SERVISE
 IS EXISTING.
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-11-30 Cont ID  
Sent By jesmith Date 2022-11-30 Time 14:13 Rev Time 0.00
Received By jesmith Date 2022-11-28 Time 16:13 Sent To  
Notes
2022-11-30 14:13:0022080820 432 25TH ST
  
 PLUMBING COMMENTS: REVIEWED FOR COMPLIANCE IN
 ACCORDANCE WITH WPB FBC 107.3.5.1.3
  
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 PROVISO #1: PROVIDE 1/2 INCH COLD WATER TO DRINKING
 FOUNTAIN
 PROVISO #2: HOT WATER PIPING FOR #434 SHALL CONFORM TO
 THE INTENT OF #434 WATER RISER DIAGRAM, NOT THE PLAN
 VIEW
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-09-14 Cont ID  
Sent By jesmith Date 2022-09-14 Time 10:32 Rev Time 0.00
Received By jesmith Date 2022-09-14 Time 10:13 Sent To  
Notes
2022-09-14 10:26:17CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 22080820 432 25TH ST
  
 1ST REVIEW
  
 GENERAL: ELECTRONIC SIGNATURES ARE NOT VALID.
  
 PLUMBING COMMENTS: DENIED
  
 1. A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL
 PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST
 BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW
 APPROVAL.
 ***A) A-3/DETAILS 2&3: PER FBC ACC 609.4, GRAB BARS
 SHALL BE INSTALLED IN A HORIZONTAL POSITION, 33 INCHES
 MINIMUM AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR
 MEASURED TO THE TOP (NOT THE CENTER) OF THE GRIPPING
 SURFACE
 ***B) A-3/DETAIL 7: PER FBC ACC 603.3, PLEASE CLEARLY
 SHOW ON PLANS THE 40 INCH DIMENSION IS TO THE
 REFLECTING SURFACE OF THE MIRROR.
 ***C) PER WPB FBC 107.2.1, PROVIDE ELEVATION DETAIL FOR
 DRINKING FOUNTAIN(S); SHOW COMPLIANCE WITH FBC 306.2,
 306.3, 602.3, 602.4, 602.5 AND 602.7.
 ***D) PER FBC ACC 602.1, DRINKING FOUNTAIN(S) SHALL
 COMPLY WITH FBC ACC 307.2 FOR PROTRUDING OBJECTS
  
 2. PER WPB FBC 107.2.1, PROVIDE WALL FINISHES FOR THE
 TOILET ROOMS AND FOR THE MOP SINK. COMPLY WITH FBC PL
 310.3 AND FBC 1210.2.2; WALLS AND PARTITIONS WITHIN 2
 FEET OF SERVICE SINKS, URINALS AND WATER CLOSETS SHALL
 HAVE A SMOOTH, HARD, NON-ABSORBENT SURFACE TO A HEIGHT
 NOT LESS THAN 4 FEET ABOVE THE FLOOR. SECTION 1210.2.2
 STIPULATES THAT THE MATERIAL BE "HARD." THE INTENT OF
 THIS SECTION IS THAT THE SURROUNDING MATERIAL SHOULD
 NOT BE OF A TYPE THAT IS EASILY DAMAGED SUCH THAT THE
 MATERIAL COULD BECOME ABSORBENT AND THUS, NOT READILY
 CLEANABLE AND SANITIZED. PAINTED DRYWALL, EVEN WHERE
 COATED WITH HIGHLY DURABLE PAINTS, DOES NOT MEET THE
 INTENT OF SECTION 1210.2.2. THE TYPICAL MATERIALS USED
 FOR THIS APPLICATION ARE CERAMIC TILE, FIBERGLASS
 REINFORCED PLASTIC (FRP) PANELS, PHENOLIC PANELS,
 LAMINATED PLASTIC PANELS, PAINTED STEEL AND STAINLESS
 STEEL.
  
 3. PER WPB FBC 107.2.1 AND WPB FBC 107.3.5.1.3(3)(13),
 PROVIDE A WATER DISTRIBUTION PLAN, A SIZED WATER RISER
 DIAGRAM AND SIZING CALCULATIONS.
 ***A) IDENTIFY POINTS OF CONNECTION TO FIXTURES AND
 EQUIPMENT.
 ***B) SHOW AND IDENTIFY WATER HAMMER ARRESTORS.
 ***C) SHOW ALL IN-LINE VALVES AS REQUIRED BY FBC PL
 606.1.
 ***D) SHOW ON THE FLOOR PLAN THE LOCATION OF THE WATER
 HEATER
 ***D) SHOW ALL BACKFLOW PREVENTERS
 ***E) PLAN SHEET A-0/PLUMBING NOTES CALL FOR EXTENDING
 WATER SERVICE TO METER, PROVIDE METER AND SHUT OFF
 VALVE IN BOX OUTSIDE OF THE BUILDING. A BACKFLOW
 PREVENTER IS REQUIRED PER FBC PL 608.1. IF THERE IS AN
 EXISTING BACKFLOW PREVENTER IN PLACE, THEN SHOW IT ON
 THE PLAN AS EXISTING.
 IF THIS REQUIRES A NEW CONNECTION TO THE CITY UTILITIES
 THEN PROVIDE A DETAIL AND A SCHEDULE. A SEPARATE PERMIT
 WILL BE REQUIRED TO BE SUBMITTED AND APPROVED PRIOR TO
 ISSUANCE OF THE PRIMARY PERMIT.
  
 4. PER WPB FBC 107.2.1, FBC PL 419.5 AND FBC PL
 607.1.2, PROVIDE IN THE SCHEDULE, AN APPROVED
 WATER-TEMPERATURE LIMITING DEVICE FOR THE SCHEDULED
 LAVATORIES THAT CONFORMS TO ASSE 1070 OR CSA B125.3
  
 5. PER WPB FBC 107.2.1 AND WPB FBC 107.3.5.1.3(5),
 PROVIDE THE ELECTRICAL CHARACTERISTICS FOR THE
 SCHEDULED WATER HEATER. COORDINATE WITH THE ELECTRICAL
 PLANS.
  
 6. PER WPB FBC 107.2.1 AND WPB FBC 107.3.5.1.3(5),
 PROVIDE ENERGY EFFICIENCY FOR WATER HEATER; COMPLY WITH
 FBC EC TABLE C404.2
  
 7. P-1/SANITARY RISER DIAGRAM: PER WPB FBC 107.2.1 AND
 WPB FBC 107.3.5.1.3(4)(13), PROVIDE SIZING OF ALL
 SEGMENTS OF SANITARY DRAIN AND VENT PIPING.
  
 8. P-1/SANITARY RISER DIAGRAM: PER FBC PL 901.2.1,
 PROVIDE A VENT FOR THE DRINKING FOUNTAIN.
  
 9. P-1/SANITARY RISER DIAGRAM: PER FBC PL 914.2,
 PROVIDE A DRY VERTICAL VENT BETWEEN THE TWO WATER
 CLOSETS.
  
 10. MANUFACTURER'S SPECIFICATION/INSTALLATION MANUAL
 FOR THE FOLLOWING SHALL BE PROVIDED FOR THE FOLLOWING:
 ***A) WATER HEATER
 ***B) BACKFLOW PREVENTER DEVICES
 ***C) THERMOSTATIC MIXING VALVES
 ALL SUBMITTALS SHALL BE APPROVED AND STAMP BY THE
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE- WPB FBC
 107.2.1, 107.3.4. SUBMITTALS MAY BE DEFERRED IN
 ACCORDANCE WITH SECTION WPB FBC 107.3.4.1 AND SHALL BE
 ON SITE PRIOR TO FINAL INSPECTION.
  
 11. PER WPB FBC 107.2.1, PROVIDE INSULATION
 SPECIFICATION SPEC FOR HOT WATER INSULATION COMPLY WITH
 FBC EC C404.4 (A-E) AND TABLE C403.2.10.
 THE FOLLOWING PIPING SHALL BE INSULATED TO LEVELS SHOWN
 IN TABLE C403.2.10:
  
 12. ALL COMPONENTS IN THE DOMESTIC WATER SYSTEM SHALL
 BE LEAD FREE IN ACCORDANCE WITH FBC PL 605.2 AND
 605.2.1. PER WPB FBC 107.2.1, PROVIDE NOTE ON PLANS
 STATING THE SAME.
  
 13. PER WPB FBC 107.2.1, PROVIDE PIPE HANGER DETAIL
 WITH A NOTE STATING, "HORIZONTAL PIPE SHALL BE
 SUPPORTED IN ACCORDANCE WITH FBC PL TABLE 308.5."
  
 14. PER WPB FBC 107.2.1, PROVIDE NOTE STATING "SEE
 A-0/PLUMBING NOTES FOR WATER AND SANITARY MATERIAL
 SPECIFICATIONS".
  
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER PX928
 PLUMBING INSPECTOR BN2148
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2023-02-13 Cont ID  
Sent By ccole Date 2023-02-13 Time 11:02 Rev Time 0.00
Received By ccole Date 2023-02-13 Time 11:02 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2023-01-26 Cont ID  
Sent By rmcphers Date 2023-01-26 Time 13:11 Rev Time 0.00
Received By rmcphers Date 2023-01-26 Time 13:11 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-01-12 Cont ID  
Sent By rmcphers Date 2023-01-12 Time 13:54 Rev Time 0.00
Received By rmcphers Date 2023-01-12 Time 13:54 Sent To  
Notes
2023-01-09 11:39:17ELECTRONIC SIGNATURES FOR PLUMBING PLANS ARE VALID. JS

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-12-07 Cont ID  
Sent By rmcphers Date 2022-12-07 Time 16:57 Rev Time 0.00
Received By rmcphers Date 2022-12-07 Time 16:57 Sent To  
Notes
2022-11-28 16:13:55ELECTRONIC SIGNATURES FOR PLUMBING ARE VALID. JS

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-12-13 Cont ID  
Sent By fgiaquin Date 2022-12-13 Time 18:39 Rev Time  
Received By fgiaquin Date   Time   Sent To  
Notes
2022-12-13 18:41:48ALL DIGITAL SIGNATURES OK. FGIAQUINTO
2022-10-06 09:02:47ALL SIGNED AND SEALED DRAWINGS NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 PROJECTDOX - SIGNED AND SEALED DRAWINGS IN PROJECTDOX
 NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED
 IN ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
2022-09-14 10:38:32ELECTRONIC SIGNATURES FOR PLUMBING PLANS ARE NOT VALID.
 JS

Review Stop Z ZONING
Rev No 4 Status P Date 2023-02-10 Cont ID  
Sent By ASangele Date 2023-02-09 Time 17:05 Rev Time 0.00
Received By asangele Date 2023-02-09 Time 17:05 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2023-01-13 Cont ID  
Sent By ASangele Date 2023-01-13 Time 15:36 Rev Time 0.00
Received By asangele Date 2023-01-13 Time 15:36 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2022-12-20 Cont ID  
Sent By ajones Date 2022-12-20 Time 13:23 Rev Time 0.00
Received By ajones Date 2022-12-20 Time 13:23 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-08-29 Cont ID  
Sent By afowlkes Date 2022-08-29 Time 09:44 Rev Time 0.00
Received By afowlkes Date 2022-08-29 Time 09:44 Sent To  
Notes
***NONE***