| Plan Review Stops For Permit 22080820 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2022-08-19 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-08-19 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-08-19 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2022-08-19 09:58:33 | WORK TO BE DONE ON TWO SEPARATE BUILDINGS ON THE | | | PARCEL, WITH THE ADDRESSES OF 432 25TH ST (EAST BLDG) | | | AND 434 25TH ST (WEST BLDG), UPDATED PERMIT DESCRIPTION | | | TO INCLUDE BOTH BUILDINGS. |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
P |
Date |
2022-12-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-12-07 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-12-07 |
Time |
16:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2022-10-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-10-06 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-10-05 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2022-10-06 08:48:56 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2023-01-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-26 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-26 |
Time |
13:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-01-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-12 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-12 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2023-01-12 13:11:07 | RENOVATION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE SHOW THE WIND DESIGN DATA USED (WIND SPEED, | | | RISK CATEGORY, EXPOSURE, ETC.) FOR WIND DESIGN - SEE | | | FBC 1603.1.4 | | | | | | 2) DOOR SIZE HAS NOT CHANGED ON THE DOOR SCHEDULE - | | | PIVOT DOOR PRODUCT APPROVAL SEE PAGE 3 OF 11 (NOTE: | | | DOOR CANNOT BE USED AS AN EGRESS DOOR WHEN THE DOOR | | | LEAF WIDTH IS MORE THAN 48") -- THE 6 FOOT WIDE ENTRY | | | DOOR SHOWN DOES NOT COMPLY WITH FBC 1010.1.1 SIZE OF | | | DOORS. THE MAXIMUM WIDTH OF A SWINGING DOOR LEAF SHALL | | | BE 48 INCHES (1219 MM) NOMINAL | | | | | | 3) SHOW THE OCCUPANCY CLASSIFICATION ON THE DRAWINGS AS | | | (S1) OR (S2) - - PLEASE SHOW THE MAIN "USE" FOR EACH | | | BUILDING ( RESTAURANT, PROFESSIONAL OFFICES, STORAGE | | | (WHAT MATERIALS OF STORAGE), RETAIL OR WHOLESALE STORE | | | ETC.) - A WAREHOUSE WOULD BE A STORAGE AREA PLEASE SEE | | | FBC SECTION 311 AND SHOW THE OCCUPANCY CLASSIFICATION | | | AS S1 OR S2 - THE OCCUPANCY CLASSIFICATION NEEDS TO BE | | | DETERMINED - FBC 302.1 OCCUPANCY CLASSIFICATION. | | | OCCUPANCY CLASSIFICATION IS THE FORMAL DESIGNATION OF | | | THE PRIMARY PURPOSE OF THE BUILDING, STRUCTURE OR | | | PORTION THEREOF. STRUCTURES SHALL BE CLASSIFIED INTO | | | ONE OR MORE OF THE OCCUPANCY GROUPS LISTED IN THIS | | | SECTION BASED ON THE NATURE OF THE HAZARDS AND RISKS TO | | | BUILDING OCCUPANTS GENERALLY ASSOCIATED WITH THE | | | INTENDED PURPOSE OF THE BUILDING OR STRUCTURE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-12-08 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-12-08 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-12-08 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2022-12-07 16:51:06 | RENOVATION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE PRODUCT APPROVALS FOR THE 8000 ALUMINUM WINDOW | | | WALL AND THE PIVOT DOOR ARE NOT COMPLETE (FRONT PAGES | | | AND THE INSTALLATION INSTRUCTIONS) - PLEASE PROVIDE | | | COMPLETE (FRONT PAGES AND THE INSTALLATION | | | INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE PRODUCT | | | APPROVALS FOR THE EXTERIOR WINDOWS AND DOORS. ALL | | | PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | | APPROVED BY THE DESIGNER OF RECORD OR BE SHOWN ON THE | | | PLANS BY PRODUCT APPROVAL NUMBER _ FBC WPB 107.3.4 | | | | | | 2) PLEASE SHOW THE WIND DESIGN DATA USED FOR WIND | | | DESIGN PER FBC 1603.1.4 | | | | | | 3) PIVOT DOOR PRODUCT APPROVAL SEE PAGE 3 OF 11 (NOTE: | | | DOOR CANNOT BE USED AS AN EGRESS DOOR WHEN THE DOOR | | | LEAF WIDTH IS MORE THAN 48") -- THE 6 FOOT WIDE ENTRY | | | DOOR SHOWN DOES NOT COMPLY WITH FBC 1010.1.1 SIZE OF | | | DOORS. THE MAXIMUM WIDTH OF A SWINGING DOOR LEAF SHALL | | | BE 48 INCHES (1219 MM) NOMINAL | | | | | | 4) PLEASE SHOW THE MAIN "USE" FOR EACH BUILDING ( | | | RESTAURANT, PROFESSIONAL OFFICES, STORAGE (WHAT | | | MATERIALS OF STORAGE), RETAIL OR WHOLESALE STORE ETC.) | | | - A WAREHOUSE WOULD BE A STORAGE AREA PLEASE SEE FBC | | | SECTION 311 AND SHOW THE OCCUPANCY CLASSIFICATION AS S1 | | | OR S2 - THE OCCUPANCY CLASSIFICATION NEEDS TO BE | | | DETERMINED - FBC 302.1 OCCUPANCY CLASSIFICATION. | | | OCCUPANCY CLASSIFICATION IS THE FORMAL DESIGNATION OF | | | THE PRIMARY PURPOSE OF THE BUILDING, STRUCTURE OR | | | PORTION THEREOF. STRUCTURES SHALL BE CLASSIFIED INTO | | | ONE OR MORE OF THE OCCUPANCY GROUPS LISTED IN THIS | | | SECTION BASED ON THE NATURE OF THE HAZARDS AND RISKS TO | | | BUILDING OCCUPANTS GENERALLY ASSOCIATED WITH THE | | | INTENDED PURPOSE OF THE BUILDING OR STRUCTURE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-10-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-10-06 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-10-05 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2022-10-06 08:48:00 | RENOVATION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS AND DOORS. | | | ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | | APPROVED BY THE DESIGNER OF RECORD OR BE SHOWN ON THE | | | PLANS BY PRODUCT APPROVAL NUMBER _ FBC WPB 107.3.4 | | | | | | 2) THE OCCUPANT LOAD SHOWN ON DRAWING CVR UNDER | | | "OCCUPANCY LOADS" SHOWS THE INCORRECT NUMBER OF | | | OCCUPANTS FOR MERCANTILE - SEE FBC TABLE 1004.5 | | | | | | 3) PLEASE SHOW THE OCCUPANT LOAD FOR EACH BUILDING | | | SEPARATELY. | | | | | | 4) PLEASE SHOW THE SQUARE FOOTAGE FOR EACH BUILDING | | | SEPARATELY. | | | | | | 5) PLEASE SHOW THE WALL LOCATION DIMENSIONS FOR ALL | | | RESTROOM AND OFFICE WALLS. | | | | | | 6) PLEASE SHOW THE WIND DESIGN DATA USED FOR WIND | | | DESIGN PER FBC 1603.1.4 | | | | | | 7) THE 6 FOOT WIDE ENTRY DOOR SHOWN DOES NOT COMPLY | | | WITH FBC 1010.1.1 SIZE OF DOORS. THE MAXIMUM WIDTH OF A | | | SWINGING DOOR LEAF SHALL BE 48 INCHES (1219 MM) | | | NOMINAL. | | | | | | 8) PLEASE SHOW THE RAMP SLOPE - FBC 405.2 SLOPE. RAMP | | | RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12. | | | | | | 9) PLEASE SHOW THE STEEL COLUMN CONNECTION TO THE ADDED | | | TIEBEAM. | | | | | | 10) PLEASE SHOW THE RESTROOM WALL FINISH - FBC 1210.2.2 | | | WALLS AND PARTITIONS. | | | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE | | | SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, | | | HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS | | | THAN 4 FEET (1219 MM) ABOVE THE FLOOR,( DRYWALL IS NOT | | | CONSIDERED A HARD SURFACE) | | | | | | 11) ACCESSIBLE RESTROOM = PLEASE SHOW THE TOILET GRAB | | | BAR MAXIMUM HEIGHT TO THE TOP OF THE GRIPPING SURFACE - | | | FBC A 609.4 POSITION OF GRAB BARS. | | | GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, | | | 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM) | | | MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF | | | THE GRIPPING SURFACE, | | | | | | 12) ACCESSIBLE RESTROOM = PLEASE USE THE WORDS | | | "REFLECTING SURFACE" WHEN REFERRING TO THE MIRROR | | | LOCATION - FBC 603.3 MIRRORS. | | | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL | | | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING | | | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH | | | FLOOR OR GROUND. | | | | | | 13) SEPARATE PERMITS ARE REQUIRED FOR SEPARATE | | | BUILDINGS. | | | | | | 14) ALL SIGNED AND SEALED DRAWINGS NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | PROJECTDOX - SIGNED AND SEALED DRAWINGS IN PROJECTDOX | | | NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED | | | IN ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2023-02-02 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-02-02 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-02-02 |
Time |
08:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2023-01-20 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-01-20 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-01-20 |
Time |
13:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-12-13 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-12-13 |
Time |
18:39 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-12-12 |
Time |
22:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-09-24 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-09-24 |
Time |
19:53 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-09-24 |
Time |
17:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2023-01-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-01-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-01-26 |
Time |
15:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2023-01-05 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-01-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-01-04 |
Time |
10:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-11-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-11-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-11-22 |
Time |
10:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2022-08-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-08-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-08-22 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2022-08-22 14:00:04 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) SHEET A 1.2 - THERE IS AN INDICATION OF A MERCANTILE | | | OCCUPANCY; HOWEVER, THERE IS ALSO AN INDICATION IN BLDG | | | 434, OF A NEW STORAGE AREA THAT IS SEPARATED BY A | | | NONRATED NON ACCESSIBLE WALL & WINDOW. | | | | | | A STORAGE OCCUPACNY IS NOT THE SAME OCCUPANCY | | | CLASSIFICATION AS MERCANTILE. | | | | | | PER NFPA 101 CH 6, TABLE 6.1.14.4.1, A 2 HOUR FIRE | | | SEPARATION IS REQUIRED. | | | | | | PLEASE REVIEW AND CORRECT OR JUSTIFIY WITH SPECIFIC | | | DETAILS AND NARRATIVE AND FIRE CODE REFERENCES. | | | | | | | | | 1A) SHOULD THIS BE CONSIDERED AS A MIXED NON-SEPARATED | | | OCCUPANCY CLASSIFICATION PLEASE REVIEW AND CORRECT AS | | | APPLICABLE. | | | | | | | | | | | | 2) ON REVIEW OF THE ABOVE COMMENTS, A STORAGE OCCUPANCY | | | NON-SEOARATED OR STAND ALONE SHALL HAVE THE HAZARD OF | | | CONTENTS REVIEWED FOR FIRE RATED SEPARATION PURPOSES. | | | | | | PER NFPA 101 | | | | | | 6.2 HAZARD OF CONTENTS | | | 6.2.1 GENERAL. | | | 6.2.1.1 FOR THE PURPOSE OF THIS CODE, THE HAZARD OF | | | CONTENTS SHALL BE | | | THE RELATIVE DANGER OF THE START AND SPREAD OF FIRE, | | | THE DANGER OF SMOKE | | | OR GASES GENERATED, AND THE DANGER OF EXPLOSION OR | | | OTHER OCCURRENCE | | | POTENTIALLY ENDANGERING THE LIVES AND SAFETY OF THE | | | OCCUPANTS OF THE | | | BUILDING OR STRUCTURE | | | | | | 6.2.1.2 HAZARD OF CONTENTS SHALL BE CLASSIFIED BY THE | | | REGISTERED DESIGN | | | PROFESSIONAL (RDP) OR OWNER AND SUBMITTED TO THE | | | AUTHORITY HAVING | | | JURISDICTION FOR REVIEW AND APPROVAL ON THE BASIS OF | | | THE CHARACTER OF THE | | | CONTENTS AND THE PROCESSES OR OPERATIONS CONDUCTED IN | | | THE BUILDING OR | | | STRUCTURE. | | | | | | 6.2.1.3* FOR THE PURPOSE OF THIS CODE, WHERE DIFFERENT | | | DEGREES OF HAZARD | | | OF CONTENTS EXIST IN DIFFERENT PARTS OF A BUILDING OR | | | STRUCTURE, THE MOST | | | HAZARDOUS SHALL GOVERN THE CLASSIFICATION, UNLESS | | | HAZARDOUS AREAS ARE | | | SEPARATED OR PROTECTED AS SPECIFIED IN SECTION 8.7 AND | | | THE APPLICABLE | | | SECTIONS OF CHAPTERS 11 THROUGH 43 | | | | | | 6.2.2 CLASSIFICATION OF HAZARD OF CONTENTS. | | | 6.2.2.1* GENERAL. THE HAZARD OF CONTENTS OF ANY | | | BUILDING OR STRUCTURE | | | SHALL BE CLASSIFIED AS LOW, ORDINARY, OR HIGH IN | | | ACCORDANCE WITH 6.2.2.2, | | | 6.2.2.3, AND 6.2.2.4 | | | | | | PLEASE PROVIDE DETAILS FO THE PROPOSED | | | PRODUCT/COMMODITY BEING STORED. | | | | | | | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2023-03-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-03-01 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-27 |
Time |
13:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-02-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-14 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-10 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-02-09 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2023-02-09 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-02-09 |
Time |
17:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-01-20 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-01-20 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-01-03 |
Time |
13:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-12-19 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-12-19 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-11-21 |
Time |
08:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-10-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-10-06 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-08-19 |
Time |
09:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2023-01-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-10-06 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-10-06 |
Time |
08:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2023-03-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-03-01 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-03-01 |
Time |
11:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2023-02-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-14 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-14 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2023-02-14 16:00:50 | 1ST REVIEW FMC | | | PERMIT: 22080820 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE ENERGY CALCULATIONS FOR THESE WAREHOUSES DO NOT | | | REFLECT WHAT IS SHOWN ON THE M-1 SHEET. THE UNIT 432 | | | HAS AN A/C LOAD OF 41,932 BUT THE DRAWING INDICATES 2 5 | | | TON UNITS. EXPLAIN WHY THE 2 5 TON UNITS. | | | FEC C403.2.2 | | | | | | 2) UNIT 434 ENERGY CALC CALLS FOR 41,683 OF COOLING BUT | | | THE M-1 DRAWING INDICATES 2 3-TON UNITS. EXPLAIN WHY | | | THE 2 3 - TON UNITS. FEC C403.2.2 | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2023-01-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-30 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-30 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2023-01-30 12:46:39 | PLEASE SUBMIT THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS ASKED FOR IN PREVIOUS REVIEWS. FEC | | | C403.2.1 | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2023-01-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-17 |
Time |
07:02 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-17 |
Time |
07:01 |
Sent To |
|
|
| Notes |
| 2023-01-17 07:02:34 | STILL MISSING THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-12-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-12-13 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-12-13 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2022-12-13 16:33:53 | 2ND REVIEW FMC | | | PERMIT: 22080820 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE MECHANICAL EQUIPMENT SIZING CALCULATIONS ARE | | | MISSING. THE REFERENCED NEW INFORMATION ON SHEET M-1 IS | | | THE OUTDOOR AIR CALCULATIONS. | | | | | | 2) THE ENERGY CALCULATIONS DO NOT SHOW THE DOORS. | | | PLEASE PROVIDE ENERGY CALCULATIONS AND MECHANICAL | | | EQUIPMENT SIZING CALCULATIONS THAT INCLUDE THE DOORS. | | | FBC 107.3.5 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-09-08 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-08 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-08 |
Time |
17:26 |
Sent To |
|
|
| Notes |
| 2022-09-08 17:26:16 | 1ST REVIEW FMC | | | PERMIT: 22080820 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) OUR RECORDS INDICATE THIS ADDRESS IS A WAREHOUSE. | | | PLEASE SHOW THIS AS A CHANGE OF USE AND OCCUPANCY. FBC | | | 107.3.5 | | | | | | 2) PROVIDE THE ENERGY CALCULATIONS FOR THIS PROJECT. | | | FEC C402.1 | | | | | | 3) PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS | | | FOR THIS PROJECT. FEC C403.2.1 | | | | | | 4) PROVIDE THE OUTDOOR AIR CALCULATIONS FOR EACH USE OF | | | SPACE FOR THIS PROJECT. FMC 403.3.1.1 AND TABLE | | | 403.3.1.1 | | | | | | 5) SHOW THE BATHROOM EXHAUST FAN TERMINATION LOCATIONS. | | | FMC 501.3 | | | | | | 6) SHOW THE ANCHORING DETAILS FOR THE CONDENSING UNITS | | | AND SHOW THE PROPERTY LINES. FBC 105.3 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-02-13 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-02-13 |
Time |
10:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2023-01-30 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2023-01-30 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2023-01-30 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2023-01-30 11:19:13 | 22080820 432 25TH ST | | | | | | PLUMBING COMMENTS: UNIT 432 ONLY IS REVIEWED FOR | | | COMPLIANCE IN ACCORDANCE WITH WPB FBC 107.3.5.1.3 | | | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | PLEASE NOTE: PER ENGINEER'S RESPONSE NARRATIVE DATED | | | 10/12/2022 AND UPLOADED 11/17/2022, THE WATER SERVICE | | | IS EXISTING. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2023-01-09 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2023-01-09 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-01-09 11:37:51 | 22080820 432 25TH ST | | | | | | PLUMBING COMMENTS: UNIT 432 ONLY IS REVIEWED FOR | | | COMPLIANCE IN ACCORDANCE WITH WPB FBC 107.3.5.1.3 | | | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | PLEASE NOTE: PER ENGINEER???S RESPONSE NARRATIVE DATED | | | 10/12/2022 AND UPLOADED 11/17/2022, THE WATER SERVISE | | | IS EXISTING. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-11-30 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2022-11-30 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2022-11-28 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2022-11-30 14:13:00 | 22080820 432 25TH ST | | | | | | PLUMBING COMMENTS: REVIEWED FOR COMPLIANCE IN | | | ACCORDANCE WITH WPB FBC 107.3.5.1.3 | | | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | PROVISO #1: PROVIDE 1/2 INCH COLD WATER TO DRINKING | | | FOUNTAIN | | | PROVISO #2: HOT WATER PIPING FOR #434 SHALL CONFORM TO | | | THE INTENT OF #434 WATER RISER DIAGRAM, NOT THE PLAN | | | VIEW | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-09-14 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2022-09-14 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2022-09-14 |
Time |
10:13 |
Sent To |
|
|
| Notes |
| 2022-09-14 10:26:17 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1 | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 22080820 432 25TH ST | | | | | | 1ST REVIEW | | | | | | GENERAL: ELECTRONIC SIGNATURES ARE NOT VALID. | | | | | | PLUMBING COMMENTS: DENIED | | | | | | 1. A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS | | | REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW | | | PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL | | | PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST | | | BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW | | | APPROVAL. | | | ***A) A-3/DETAILS 2&3: PER FBC ACC 609.4, GRAB BARS | | | SHALL BE INSTALLED IN A HORIZONTAL POSITION, 33 INCHES | | | MINIMUM AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR | | | MEASURED TO THE TOP (NOT THE CENTER) OF THE GRIPPING | | | SURFACE | | | ***B) A-3/DETAIL 7: PER FBC ACC 603.3, PLEASE CLEARLY | | | SHOW ON PLANS THE 40 INCH DIMENSION IS TO THE | | | REFLECTING SURFACE OF THE MIRROR. | | | ***C) PER WPB FBC 107.2.1, PROVIDE ELEVATION DETAIL FOR | | | DRINKING FOUNTAIN(S); SHOW COMPLIANCE WITH FBC 306.2, | | | 306.3, 602.3, 602.4, 602.5 AND 602.7. | | | ***D) PER FBC ACC 602.1, DRINKING FOUNTAIN(S) SHALL | | | COMPLY WITH FBC ACC 307.2 FOR PROTRUDING OBJECTS | | | | | | 2. PER WPB FBC 107.2.1, PROVIDE WALL FINISHES FOR THE | | | TOILET ROOMS AND FOR THE MOP SINK. COMPLY WITH FBC PL | | | 310.3 AND FBC 1210.2.2; WALLS AND PARTITIONS WITHIN 2 | | | FEET OF SERVICE SINKS, URINALS AND WATER CLOSETS SHALL | | | HAVE A SMOOTH, HARD, NON-ABSORBENT SURFACE TO A HEIGHT | | | NOT LESS THAN 4 FEET ABOVE THE FLOOR. SECTION 1210.2.2 | | | STIPULATES THAT THE MATERIAL BE "HARD." THE INTENT OF | | | THIS SECTION IS THAT THE SURROUNDING MATERIAL SHOULD | | | NOT BE OF A TYPE THAT IS EASILY DAMAGED SUCH THAT THE | | | MATERIAL COULD BECOME ABSORBENT AND THUS, NOT READILY | | | CLEANABLE AND SANITIZED. PAINTED DRYWALL, EVEN WHERE | | | COATED WITH HIGHLY DURABLE PAINTS, DOES NOT MEET THE | | | INTENT OF SECTION 1210.2.2. THE TYPICAL MATERIALS USED | | | FOR THIS APPLICATION ARE CERAMIC TILE, FIBERGLASS | | | REINFORCED PLASTIC (FRP) PANELS, PHENOLIC PANELS, | | | LAMINATED PLASTIC PANELS, PAINTED STEEL AND STAINLESS | | | STEEL. | | | | | | 3. PER WPB FBC 107.2.1 AND WPB FBC 107.3.5.1.3(3)(13), | | | PROVIDE A WATER DISTRIBUTION PLAN, A SIZED WATER RISER | | | DIAGRAM AND SIZING CALCULATIONS. | | | ***A) IDENTIFY POINTS OF CONNECTION TO FIXTURES AND | | | EQUIPMENT. | | | ***B) SHOW AND IDENTIFY WATER HAMMER ARRESTORS. | | | ***C) SHOW ALL IN-LINE VALVES AS REQUIRED BY FBC PL | | | 606.1. | | | ***D) SHOW ON THE FLOOR PLAN THE LOCATION OF THE WATER | | | HEATER | | | ***D) SHOW ALL BACKFLOW PREVENTERS | | | ***E) PLAN SHEET A-0/PLUMBING NOTES CALL FOR EXTENDING | | | WATER SERVICE TO METER, PROVIDE METER AND SHUT OFF | | | VALVE IN BOX OUTSIDE OF THE BUILDING. A BACKFLOW | | | PREVENTER IS REQUIRED PER FBC PL 608.1. IF THERE IS AN | | | EXISTING BACKFLOW PREVENTER IN PLACE, THEN SHOW IT ON | | | THE PLAN AS EXISTING. | | | IF THIS REQUIRES A NEW CONNECTION TO THE CITY UTILITIES | | | THEN PROVIDE A DETAIL AND A SCHEDULE. A SEPARATE PERMIT | | | WILL BE REQUIRED TO BE SUBMITTED AND APPROVED PRIOR TO | | | ISSUANCE OF THE PRIMARY PERMIT. | | | | | | 4. PER WPB FBC 107.2.1, FBC PL 419.5 AND FBC PL | | | 607.1.2, PROVIDE IN THE SCHEDULE, AN APPROVED | | | WATER-TEMPERATURE LIMITING DEVICE FOR THE SCHEDULED | | | LAVATORIES THAT CONFORMS TO ASSE 1070 OR CSA B125.3 | | | | | | 5. PER WPB FBC 107.2.1 AND WPB FBC 107.3.5.1.3(5), | | | PROVIDE THE ELECTRICAL CHARACTERISTICS FOR THE | | | SCHEDULED WATER HEATER. COORDINATE WITH THE ELECTRICAL | | | PLANS. | | | | | | 6. PER WPB FBC 107.2.1 AND WPB FBC 107.3.5.1.3(5), | | | PROVIDE ENERGY EFFICIENCY FOR WATER HEATER; COMPLY WITH | | | FBC EC TABLE C404.2 | | | | | | 7. P-1/SANITARY RISER DIAGRAM: PER WPB FBC 107.2.1 AND | | | WPB FBC 107.3.5.1.3(4)(13), PROVIDE SIZING OF ALL | | | SEGMENTS OF SANITARY DRAIN AND VENT PIPING. | | | | | | 8. P-1/SANITARY RISER DIAGRAM: PER FBC PL 901.2.1, | | | PROVIDE A VENT FOR THE DRINKING FOUNTAIN. | | | | | | 9. P-1/SANITARY RISER DIAGRAM: PER FBC PL 914.2, | | | PROVIDE A DRY VERTICAL VENT BETWEEN THE TWO WATER | | | CLOSETS. | | | | | | 10. MANUFACTURER'S SPECIFICATION/INSTALLATION MANUAL | | | FOR THE FOLLOWING SHALL BE PROVIDED FOR THE FOLLOWING: | | | ***A) WATER HEATER | | | ***B) BACKFLOW PREVENTER DEVICES | | | ***C) THERMOSTATIC MIXING VALVES | | | ALL SUBMITTALS SHALL BE APPROVED AND STAMP BY THE | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE- WPB FBC | | | 107.2.1, 107.3.4. SUBMITTALS MAY BE DEFERRED IN | | | ACCORDANCE WITH SECTION WPB FBC 107.3.4.1 AND SHALL BE | | | ON SITE PRIOR TO FINAL INSPECTION. | | | | | | 11. PER WPB FBC 107.2.1, PROVIDE INSULATION | | | SPECIFICATION SPEC FOR HOT WATER INSULATION COMPLY WITH | | | FBC EC C404.4 (A-E) AND TABLE C403.2.10. | | | THE FOLLOWING PIPING SHALL BE INSULATED TO LEVELS SHOWN | | | IN TABLE C403.2.10: | | | | | | 12. ALL COMPONENTS IN THE DOMESTIC WATER SYSTEM SHALL | | | BE LEAD FREE IN ACCORDANCE WITH FBC PL 605.2 AND | | | 605.2.1. PER WPB FBC 107.2.1, PROVIDE NOTE ON PLANS | | | STATING THE SAME. | | | | | | 13. PER WPB FBC 107.2.1, PROVIDE PIPE HANGER DETAIL | | | WITH A NOTE STATING, "HORIZONTAL PIPE SHALL BE | | | SUPPORTED IN ACCORDANCE WITH FBC PL TABLE 308.5." | | | | | | 14. PER WPB FBC 107.2.1, PROVIDE NOTE STATING "SEE | | | A-0/PLUMBING NOTES FOR WATER AND SANITARY MATERIAL | | | SPECIFICATIONS". | | | | | | | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER PX928 | | | PLUMBING INSPECTOR BN2148 | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-246-0882 | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-02-13 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-02-13 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2023-01-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-26 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-26 |
Time |
13:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-01-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-12 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-12 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2023-01-09 11:39:17 | ELECTRONIC SIGNATURES FOR PLUMBING PLANS ARE VALID. JS |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-12-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-12-07 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-12-07 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2022-11-28 16:13:55 | ELECTRONIC SIGNATURES FOR PLUMBING ARE VALID. JS |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-12-13 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-12-13 |
Time |
18:39 |
Rev Time |
|
| Received By |
fgiaquin |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-12-13 18:41:48 | ALL DIGITAL SIGNATURES OK. FGIAQUINTO | | 2022-10-06 09:02:47 | ALL SIGNED AND SEALED DRAWINGS NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | PROJECTDOX - SIGNED AND SEALED DRAWINGS IN PROJECTDOX | | | NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED | | | IN ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | 2022-09-14 10:38:32 | ELECTRONIC SIGNATURES FOR PLUMBING PLANS ARE NOT VALID. | | | JS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2023-02-10 |
|
|
Cont ID |
|
| Sent By |
ASangele |
Date |
2023-02-09 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-02-09 |
Time |
17:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2023-01-13 |
|
|
Cont ID |
|
| Sent By |
ASangele |
Date |
2023-01-13 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-01-13 |
Time |
15:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-12-20 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2022-12-20 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2022-12-20 |
Time |
13:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-08-29 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-08-29 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-08-29 |
Time |
09:44 |
Sent To |
|
|
| Notes |
|
|