| 2023-03-20 13:37:57 | 2ND BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | 1.CORRECTED. | | | | | | 2. PROVIDE A SITE PLAN.... | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE | | | AND INCLUDED BOUNDARY LINE SURVEY. | | | | | | 3. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 | | | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | | | | NOTICE: A SOILS REPORT IS NOT REQUIRED. | | | | | | 4. PROVIDE AN ENERGY SUBMITTAL RESIDENTIAL (RE) | | | R401.2COMPLIANCE. | | | SECTION R405 AND THE PROVISIONS OF SECTIONS R401 | | | THROUGH R404 LABELED MANDATORY. | | | | | | 5. IDENTIFY THE CEILING AND WALL INSULATION TYPE AND | | | R-VALUE ON PLANS. (DETAIL 1/S-4 INDICATES CEILING | | | INSULATIONB SHALL BE R-1) | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | 6. CORRECTED (SEE PLAN PAGES A-6 & A-7) | | | | | | 7. PROVIDE CURRENT PRODUCT APPROVALS OR NOA FOR | | | PROPOSED WINDOWS AND DOORS. | | | PRODUCT APPROVALS INCLUDE THE COVER SHEET, EVALUATION | | | REPORT AND INSTALLATION INSTRUCTIONS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-11-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-08 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-11-07 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2022-11-08 07:33:31 | 1ST BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | 1.PROVIDE A COPY OF THE MOST RECENT BOUNDARY LINE | | | SURVEY. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. PROVIDE A SITE PLAN.... | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE | | | AND INCLUDED BOUNDARY LINE SURVEY. | | | | | | 3. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 | | | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | | | | NOTICE: A SOILS REPORT IS NOT REQUIRED. | | | | | | 4. PROVIDE AN ENERGY SUBMITTAL RESIDENTIAL (RE) | | | R401.2COMPLIANCE. | | | SECTION R405 AND THE PROVISIONS OF SECTIONS R401 | | | THROUGH R404 LABELED MANDATORY. | | | | | | 5. IDENTIFY THE CEILING AND WALL INSULATION TYPE AND | | | R-VALUE ON PLANS. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | 6. PROVIDE A WINDOW AND DOOR SCHEDULE. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | 7. PROVIDE CURRENT PRODUCT APPROVALS OR NOA FOR | | | PROPOSED WINDOWS AND DOORS. | | | PRODUCT APPROVALS INCLUDE THE COVER SHEET, EVALUATION | | | REPORT AND INSTALLATION INSTRUCTIONS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2023-05-24 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-05-24 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-05-24 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2023-05-24 11:34:21 | ELECTRIC REVIEW FAILED | | | | | | 1) PLANS NOW DETAIL GAS TANKLESS WATER HEATER AND GAS | | | RANGE, HOWEVER, NO GAS PLANS HAVE BEEN SUBMITTED. AS | | | THIS WOULD AFFECT THE ELECTRIC LOAD CALCULATION, PLEASE | | | CLARIFY WHAT THE ACTUAL APLLIANCES WILL BE. FBC 107.2 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-03-27 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-03-27 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-03-27 |
Time |
07:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-10-18 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-10-18 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2022-10-18 13:09:21 | ELECTRIC REVIEW FAILED | | | | | | 1) PLEASE DETAIL ALL THE OUTSIDE RECEPTACLES AS | | | REQUIRED PER NEC 210.52(E), 210.63 AND 210.64 | | | 2) PLEASE NUMBER THE A/C MINI SPLIT UNITS AND THERE | | | ASSOCIATED CONDENSERS. FBC 107.2 | | | 3) PLEASE DETAIL THE SECOND FLOOR SMOKE ALARM AS A | | | COMBINATION CARBON MONOXIDE AND SMOKE ALARM AS REQUIRED | | | PER FBC R 315.1 | | | 4) PLEASE DETAIL HOW OUTDOOR FLOOD LIGHTS ARE | | | CONTROLLED. FBC 107.2 | | | 5) PLEASE LOCATE AIR HANDLER AND COMPRESSOR, LISTED IN | | | PANEL SCHEDULE, ON ELECTRIC FLOOR PLAN. FBC 107.2 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2023-07-05 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-07-05 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-07-05 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2023-07-05 16:19:43 | ANY EXISTING WINDOWS SHALL NOT BE REPLACED UNLESS UNDER | | | A SEPARATE PERMIT. SOME INCONSISTENCIES SHOWN WITH | | | EXISTING AND PROPOSED WINDOWS COMPARED TO APPROVED | | | PLANS. | | | | | | PLEASE ALSO ENSURE THAT ALL WINDOWS HAVE CLEAR GLASS | | | AND LOW E COATING WILL ONLY BE APPLIED SIDES AND REAR | | | IF APPLICABLE. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-03-14 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2023-03-14 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2023-03-14 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-10-24 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-10-24 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-10-24 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2022-10-24 08:41:46 | REQUIRES SUBMITTAL OF COA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-07-06 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-07-06 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-05-10 |
Time |
09:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-03-27 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-03-27 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-03-13 |
Time |
12:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-11-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-08 |
Time |
07:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-09-30 |
Time |
09:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-11-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-07 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-11-07 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2022-11-07 16:36:31 | IMPACT FEES | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2023-05-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-23 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-05-23 |
Time |
16:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2023-05-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-05-11 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-05-11 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2023-05-11 11:22:52 | 1) PROVIDE THE ENERGY CALCULATIONS FOR THIS PROJECT. | | | FEC R101.5.1.1.1 | | | | | | 2) PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS | | | FOR THIS PROJECT. FEC R403.7.1 | | | | | | 3) PROVIDE MORE DETAILS FOR THE KITCHEN RANGE HOOD. IS | | | THIS HOOD VENTED TO THE OUTDOORS? IF SO, SHIW THE | | | TERMINATION LOCATION ON THE DRAWING. FRC M1503 | | | | | | 4) PROVIDE THE CFMS OF THE KITCHEN HOOD FAN MOTOR. SHOW | | | MAKEUP AIR IF REQUIRED BY FRC M1503.4 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2023-03-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-03-14 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-03-14 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2023-03-14 10:30:05 | THE ONLY DOCUMENT SSUBMITTED FOR THE MECHANICAL WAS THE | | | CORRECTION LETTER. PLEASE SUBMIT THE COMPLETE | | | MECHANICAL DESIGN FOR THIS PROJECT. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-10-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-10-17 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-17 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2022-10-17 09:23:26 | 1ST REVIEW FMC | | | PERMIT: 22080669 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE A COMPLETE MECHANICAL DESIGN FOR THIS | | | PROJECT INCLUDING: | | | FBC 107.3.5 | | | MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING | | | OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA | | | AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION | | | PLAN; FLOOR/ROOF | | | FRAMING PLAN OR TRUSS LAYOUT; ALL FENESTRATION | | | PENETRATIONS; FLASHING; AND ROUGH OPENING DIMENSIONS; | | | AND ALL EXTERIOR ELEVATIONS: | | | | | | MECHANICAL: | | | 1. ENERGY CALCULATIONS | | | 2. EXHAUST SYSTEMS: | | | CLOTHES DRYER EXHAUST | | | KITCHEN EQUIPMENT EXHAUST | | | SPECIALTY EXHAUST SYSTEMS | | | 3. EQUIPMENT | | | 4. EQUIPMENT LOCATION | | | 5. MAKE-UP AIR | | | 6. ROOF-MOUNTED EQUIPMENT | | | 7. DUCT SYSTEMS | | | 8. VENTILATION | | | 9. COMBUSTION AIR | | | 10. CHIMNEYS, FIREPLACES AND VENTS | | | 11. APPLIANCES | | | 12. BOILERS | | | 13. REFRIGERATION | | | 14. BATHROOM VENTILATION | | | 15. LABORATORY | | | 16. DESIGN FLOOD ELEVATION | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2023-05-12 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-12 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-12 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2023-05-12 09:31:04 | 3RD PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | NEW COMMENTS | | | | | | 1. 2020 FRC P3107.1 - THE WASHER, TUB, AND WATER CLOSET | | | ARE NOT VENTED CORRECTLY AND DO NOT REPRESENT THE FLOOR | | | PLAN. THE WATER CLOSET IS NOT ON THE SAME WALL. ALSO, A | | | COMMON VENT IS LIMITED TO TWO P-TRAPS. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2023-03-14 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-03-14 |
Time |
06:59 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-03-14 |
Time |
06:59 |
Sent To |
|
|
| Notes |
| 2023-03-14 07:07:44 | 2ND PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | NEW COMMENTS | | | | | | 1. 2020 FRC P3101.2.1 - THE UPSTAIRS BATHROOM IS | | | CONNECTED TO THE STACK WITHOUT A VENT FOR ANY OF THE | | | FIXTURES. PROVIDE VENTING FOR THE UPSTAIRS BATHROOM. | | | | | | 2. 2020 FRC P3108.1 - DOWNSTAIRS BATHROOM - THE MASTER | | | BATHROOM'S WATER CLOSET AND LAVATORY ARE CONNECTED TO A | | | STACK WITHOUT VENTING. TYPICALLY, BATHROOM GROUP | | | FIXTURES DO NOT CONNECT TO STACKS AND THE WATER CLOSET | | | IS CONNECTED ABOVE THE LAV, WHICH IS ALSO NOT ALLOWED. | | | | | | 3. 2020 FRC P3201.7 - THE MINIMUM SIZE OF THE AUTOMATIC | | | CLOTHES WASHER DRAIN IS 2" | | | | | | 4. THE TUB DRAIN IS DRAWN "ABOVE" THE WASHER DRAIN ON A | | | VERTICAL RISER. THIS DOES NOT MATCH THE FLOOR PLAN. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-10-06 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-06 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-10-06 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2022-10-06 14:24:55 | 1ST PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2017 WPB AMEND 107.3.5.3 (12) - THE RISER SUPPLIED | | | DOES NOT REPRESENT ACTUAL PLUMBING. ON THE SECOND | | | FLOOR, THE SHOWER CONNECTS TO THE RISER ABOVE THE | | | LAVATORY FIXTURE DRAIN? | | | | | | 2. 2020 FRC P3108.1 - DOWNSTAIRS BATHROOM - THE TUB AND | | | WATER CLOSET CONNECT UPSTREAM OF THE VENTED FIXTURE | | | CONNECTION AND ONLY ONE TRAPPED FIXTURE IS ALLOWED | | | UPSTREAM. | | | | | | 3. 2017 WPB AMEND 107.2.1 - ALSO, THERE ARE 4 WATER | | | CLOSETS SHOWN ON THE DIAGRAM AND ONLY 3 WATER CLOSETS | | | ON THE FLOOR PLAN. PLEASE CORRECT. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2022-11-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-08 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-11-07 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2022-11-08 07:25:26 | PROVISO ON PLAN PAGE A-1: A SEPERATE ROOFING PERMIT IS | | | REQUIRED. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-05-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-23 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-23 |
Time |
12:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2023-03-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-03-20 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-03-20 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2023-03-20 13:14:48 | 2ND SIGNATURE REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: ALL PLAN PAGES | | | | | | NOTICE: FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF | | | CERTIFY DIGITAL SIGNATURES AND SEALS. | | | THE SIGNATURE MUST BE THIRD PARTY VERIFIED PER F.S. | | | 668.003 (3) AND F.A.C. 61G15-23.005. | | | | | | 1.DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A | | | VALID DIGITAL SIGNATURE. | | | A SCAN OF A WET SEAL AND SIGNATURE OR DIGITAL SIGNATURE | | | IS NOT CONSIDERED A VALID DIGITAL SIGNATURE. | | | | | | 2.SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE PER F.S. | | | 668.003 (3); | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5). | | | F.S. 471; F.A.C. 61G15-23.005 (ENGINEERS) | | | F.S. 481; F.A.C. 61G1-16.005 (ARCHITECTS) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-10-18 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-10-18 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2022-10-18 13:10:03 | SIGNATURE REVIEW FAILED | | | FS471/FS481 DOCUMENTS PREPARED BY ARCHITECT/ENGINEER OF | | | RECORD AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | DIGITALLY SEALED AND SIGNED. | | | | | | PLEASE SUBMIT DIGITALLY SEALED AND SIGNED PLANS | | | FOLLOWING PROJECTDOX INSTRUCTIONS | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2023-07-05 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-07-05 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-07-05 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2023-07-05 15:53:07 | SEE PREVIOUS REVIEWS. LANDSCAPE PERMIT NOT SUBMITTED |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2023-03-14 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2023-03-14 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2023-03-14 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2023-03-14 14:30:02 | PERMIT VALUE EXCEEDS 50% OF IMPROVEMENT VALUE, REQUIRES | | | SUBMITTAL OF SEPERATE LANDSCAPE PERMIT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-10-24 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-10-24 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-10-24 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2022-10-24 08:42:13 | REQUIRES A SURVEY, SITE PLAN AND SF BREAKDOWN |
|
|