Plan Review Details - Permit 22080650
Plan Review Stops For Permit 22080650
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-11-14 Cont ID  
Sent By jwitmer Date 2022-11-14 Time 09:39 Rev Time 0.00
Received By jwitmer Date 2022-11-14 Time 09:35 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-09-20 Cont ID  
Sent By jwitmer Date 2022-09-20 Time 11:59 Rev Time 0.00
Received By jwitmer Date 2022-09-20 Time 11:01 Sent To  
Notes
2022-09-20 11:58:53WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22080650
 ADD: 415 NORTHWOOD RD.
 CONT: T & P PLASTERING
 TEL: 561-718-9759
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. SEPT. 20/2022
 ACTION: DENIED
  
 1) THE SUBMITTED FLOOR PLAN DOES NOT INDICATE WHAT TYPE
 OCCUPANCY IS TAKEN PLACE, USAGE, NOR HAS THE FLOOR PLAN
 INDICATED THE OCCUPANT LOAD. THE PLANS SHOW A INTERIOR
 STAIRWAY 108 AND AN EXISTING LULA LIFT.
 PERMIT 16061686 WAS FOR A SINGLE TENANT THAT WAS 1ST &
 2ND FLOOR. THIS PLAN DOES NOT PROVIDE WHO IS GOING TO
 OCCUPY THE 2ND FLOOR THIS PROPOSED USE CANNOT CREATE A
 NONCONFORMITY.
 2020 EXISTING BUILDING CODE 1101.2 / / LEVEL II 801.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING. CREATION OR
 EXTENSION OF NONCONFORMITY. ALL NEW WORK,
 RE-CONFIGURATION SHALL NOT CREATE OR EXTEND ANY
 NONCONFORMITY IN THE EXISTING BUILDING TO WHICH THE
 RE-CONFIGURATION OF SPACE IS BEING MADE WITH REGARD TO
 ACCESSIBILITY, STRUCTURAL STRENGTH, FIRE SAFETY, MEANS
 OF EGRESS, OR THE CAPACITY OF MECHANICAL, PLUMBING, OR
 ELECTRICAL SYSTEMS.
  
 2) THE 2ND FLOOR TENANT WILL NEED ACCESS TO THE REAR
 STAIRS AND NOT GO THROUGH THE 1ST FLOOR TENANCY, NOT
 UNDER THEIR CONTROL. SEE 2020 FBC-BUILDING SECTION
 1016.2.2 & 3.
  
 3) THE PHOTO INDICATES A NEW SIVA CAF??, THE FLOOR PLAN
 DOES NOT SHOW COUNTER HEIGHT AT POINT OF SALE
 COMPLIANCE WITH 2020 ACCESS.:
 3A) CODE 904.3.3 CHECK WRITING SURFACES. WHERE
 PROVIDED, CHECK WRITING SURFACES SHALL COMPLY WITH
 902.3HEIGHT. THE TOPS OF WORK SURFACES SHALL BE 28
 INCHES MINIMUM AND 34 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
  
 3B) SHOW COMPLIANCE WITH THE ACCESS. CODE 305.5
 POSITION. UNLESS OTHERWISE SPECIFIED, CLEAR FLOOR OR
 GROUND SPACE SHALL BE POSITIONED FOR EITHER A FORWARD
 OR PARALLEL APPROACH TO AN ELEMENT.
  
 3C) 904.4 SALES AND SERVICE COUNTERS. SALES COUNTERS
 AND SERVICE COUNTERS SHALL COMPLY WITH 904.4.1 OR
 904.4.2. THE ACCESSIBLE PORTION OF THE COUNTERTOP SHALL
 EXTEND THE SAME DEPTH AS THE SALES OR SERVICE COUNTER
 TOP.
  
 4) THE FLOOR PLAN DOES NOT INDICATE IF THERE WILL BE
 SEATING, THE LIFE SAFETY SHEET DOES NOT SHOW COMPLIANCE
 WITH THE 2020 FBC-ACCESSIBILITY CODE.
 4A) 226.1 WHERE DINING SURFACES ARE PROVIDED FOR THE
 CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE
 SEATING SPACES AND STANDING SPACES AT THE DINING
 SURFACES SHALL COMPLY WITH 902.
  
 4B) 902.1. DINING SURFACES AND WORK SURFACES SHALL
 COMPLY WITH 902.2 AND 902.3. ADVISORY 902.1 GENERAL.
 DINING SURFACES INCLUDE, BUT ARE NOT LIMITED TO, BARS,
 TABLES, LUNCH COUNTERS, AND BOOTHS.
  
 4B)(1) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR
 SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD
 APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED.
  
 4B)(2) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND
 WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 5) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-08-17 Cont ID  
Sent By pleduc Date 2022-08-17 Time   Rev Time 0.00
Received By pleduc Date 2022-08-17 Time 16:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-03-06 Cont ID  
Sent By asangele Date 2023-03-06 Time 14:36 Rev Time 0.00
Received By asangele Date 2023-03-06 Time 14:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-01-13 Cont ID  
Sent By asangele Date 2023-01-13 Time 11:47 Rev Time 0.00
Received By asangele Date 2023-01-13 Time 11:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2022-09-20 Time   Rev Time 0.00
Received By cdecoeur Date 2022-08-16 Time 07:27 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2023-02-24 Cont ID  
Sent By ccole Date 2023-02-24 Time 16:02 Rev Time 0.00
Received By ccole Date 2023-02-24 Time 16:02 Sent To  
Notes
2023-02-24 16:03:19GREASE INTERCEPTOR UNDER PERMIT 23020862.

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-11-17 Cont ID  
Sent By ccole Date 2022-11-17 Time 13:53 Rev Time 0.00
Received By ccole Date 2022-11-17 Time 12:29 Sent To  
Notes
2022-11-17 14:01:032ND REVIEW FBC-2020 PLUMBING
 PERMIT- 22080650
 11/17/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENT #3 FROM THE
 1ST REVIEW ARE LISTED BELOW. PLEASE REVIEW THE COMMENT
 AND CONTACT ME IF YOU HAVE ANY QUESTIONS.
  
 3) P1.1: THE PLUMBING ALTERATIONS INCLUDING THE GREASE
 INTERCEPTOR ARE BEING REVIEWED UNDER THIS MASTER PERMIT
 HOWEVER A SEPARATE PERMIT AND PLANS IS REQUIRED FOR
 INSTALLATION OF THE GREASE INTERCEPTOR- SECS. 105.1 &
 107.2.1 WPB.
 PLEASE NOTE: DUE TO A CHANGE IN PROCESS, THE GREASE
 INTERCEPTOR PERMIT IS REQUIRED TO BE SUBMITTED PRIOR TO
 ISSUANCE OF THE PRIMARY PERMIT (AS APPLICABLE). YOU CAN
 SUBMIT AN APPLICATION "TBD" (TO BE DETERMINED) IF YOU
 DO NOT HAVE A CONTRACTOR SELECTED BY EMAILING A
 COMPLETED PERMIT APPLICATION TO [email protected]
 . YOU WILL RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD
 PLANS. YOU MAY UPLOAD PLANS AND PAY FEES AT A FUTURE
 DATE, BUT THE APPLICATION IS REQUIRED AT THIS TIME. WE
 RECOMMEND THAT YOU PAY FEES AND UPLOAD PLANS AT THE
 SAME TIME. AFTER YOU HAVE THE PERMIT(S) GENERATED,
 NOTIFY ME VIA EMAIL AND I WILL CHANGE THE REVIEW STATUS
 TO PASS.
  
 PLEASE NOTE THE FOLLOWING PLAN REVIEW SUBMITTAL
 REQUIREMENTS FOR THE INTERCEPTOR- SECS. 1003.1-
 1003.3.8 FBC P.
 A) MANUFACTURER'S SPECIFICATIONS AND INSTALLATION
 GUIDELINES- SECS.1003.3.5 OR 1003.3.7 FBC P.
 B) EQUIPMENT SCHEDULE INDICATING THE MAKE AND MODEL AND
 CAPACITY OF THE UNIT.
 C) SIZING CALCULATIONS IN ACCORDANCE WITH ASME
 A112.14.3, ASME A112.14.4, ASME A112.14.6, CSA B481.3,
 OR PDI G101 FOR HYDROMECHANICAL TYPES.
 D) FLOOR PLAN DRAWING SHOWING THE LOCATION OF THE UNIT
 AND ELEVATION DETAIL
 E) PIPING DIAGRAM INCLUDING LOCATIONS AND SIZES OF
 INLETS, OUTLETS, CLEANOUTS, FLOW CONTROL VENTS, AND
 SAMPLING PORTS.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-08-26 Cont ID  
Sent By ccole Date 2022-08-26 Time 08:36 Rev Time 0.00
Received By ccole Date 2022-08-26 Time 07:20 Sent To  
Notes
2022-08-26 08:38:151ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22080650
 8/26/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS A-1 & P1.1: THE PLANS AND PHOTOS INDICATE THE
 PROJECT IS PLUMBING PREP WORK FOR A NEW BUSINESS- SIVA
 CAFE. THE PREVIOUS BUSINESS AT THE LOCATION WAS
 WANDERER BRACELETS WHICH COMPLETED AN INTERIOR REMODEL
 UNDER PERMIT 16061686. PLEASE REFER TO SEC. 1001.1 FBC
 EXISTING BUILDING CODE-2020 AND PROVIDE CODE DATA ON
 THE PLAN INCLUDING COMPLIANCE AS EITHER A CHANGE OF
 OCCUPANCY OR CHANGE OF USE.
  
 2) A-1 & P1.1: REFER TO SEC. 1010.1 FBC EX AND PROVIDE
 PLUMBING FIXTURE CALCULATIONS FOR THE NEW TENANT SPACE
 IN ACCORDANCE WITH TABLE 403.1 FBC P. SHOW THE REQUIRED
 AND PROVIDED NUMBER OF FIXTURES BASED ON THE OCCUPANCY
 AND USE OF THE SPACE.
  
 3) P1.1: THE PLUMBING ALTERATIONS INCLUDING THE GREASE
 INTERCEPTOR ARE BEING REVIEWED UNDER THIS MASTER PERMIT
 HOWEVER A SEPARATE PERMIT AND PLANS IS REQUIRED FOR
 INSTALLATION OF THE GREASE INTERCEPTOR- SECS. 105.1 &
 107.2.1 WPB. PLEASE NOTE: DUE TO A CHANGE IN PROCESS,
 THE GREASE INTERCEPTOR PERMIT IS REQUIRED TO BE
 SUBMITTED PRIOR TO ISSUANCE OF THE PRIMARY PERMIT (AS
 APPLICABLE). YOU CAN SUBMIT AN APPLICATION ?TBD? (TO BE
 DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR SELECTED BY
 EMAILING A COMPLETED PERMIT APPLICATION TO
 [email protected] . YOU WILL RECEIVE INSTRUCTIONS
 TO PAY FEES AND UPLOAD PLANS. YOU MAY UPLOAD PLANS AND
 PAY FEES AT A FUTURE DATE, BUT THE APPLICATION IS
 REQUIRED AT THIS TIME. WE RECOMMEND THAT YOU PAY FEES
 AND UPLOAD PLANS AT THE SAME TIME. AFTER YOU HAVE THE
 PERMIT(S) GENERATED, NOTIFY ME VIA EMAIL AND I WILL
 CHANGE THE REVIEW STATUS TO PASS.
  
 4) P1.1: PROVIDE A PLUMBING FIXTURE SCHEDULE ON THE
 PLAN INDICATING THE MAKES AND MODELS OF THE
 3-COMPARTMENT SINK, GREASE INTERCEPTOR, THE HAND SINK,
 WATER PURIFICATION SINK, FLOOR SINK, FILTRATION SYSTEM,
 AND SINK FAUCETS- SEC. 107.3.5.1.3 WPB.
  
 5) P1.1: PROVIDE A WATER SUPPLY PLAN OR WATER RISER-
 SEC. 107.3.5.1.3 WPB. PLEASE INCLUDE WATER LINES TO
 FIXTURES AND APPLIANCES INCLUDING THE DISHWASHER,
 BEVERAGE AND COFFEE MACHINES.
  
 6) P1.1: THE SANITARY ISOMETRIC DOES NOT SHOW THE
 PIPING CONNECTIONS TO THE GREASE INTERCEPTOR AND THE
 DISHWASHER- SEC. 107.3.5.1.3 WPB.
  
 7) PLEASE PROVIDE AN ENLARGED PIPING DETAIL SHOWING THE
 CONNECTIONS FROM THE 3-COMPARTMENT SINK TO THE GREASE
 INTERCEPTOR- SECS. 802.1.1 & 1003.3.5 FBC P.
  
 8) P1.1: PROVIDE SIZING CALCULATIONS ON THE PLAN FOR
 THE INTERCEPTOR- SEC. 1003.3.5.1 FBC P.
  
 9) P1.1: THE DRAINAGE FROM THE MOP SINK SHALL DISCHARGE
 INTO THE GREASE WASTE LINE AND INTERCEPTOR- SEC.
 1003.3.1 FBC P. THE ISOMETRIC SHOWS THE DRAIN
 CONNECTING TO THE SANITARY LINE.
  
 10) P1.1 NOTE 3: THE NOTE AND PHOTOS APPEAR TO SHOW THE
 MOP SINK AND WATER HEATER HAVE BEEN RELOCATED FROM
 THEIR ORIGINAL LOCATIONS UNDER PERMIT- 16061686. PLEASE
 MODIFY THE SCOPE OF WORK AND DRAWINGS ACCORDINGLY- SEC.
 107.2.1 WPB. PLEASE NOTE THE WATER HEATER APPROVED
 UNDER PERMIT 16061686 WAS A 40-GALLON LOCHNIVAR. THE
 PHOTOS INDICATE AN AO SMITH WHICH APPEARS TO BE NEW-
 PLEASE CLARIFY.
  
 11) PLEASE NOTE AN ELECTRICAL PLAN AND SUB-PERMIT WILL
 BE REQUIRED FOR POWER SUPPLY TO THE DISHWASHER AND
 RELOCATION OF THE WATER HEATER (IF APPLICABLE TO THE
 PROJECT)- SECS. 105.1 & 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2022-09-20 Cont ID  
Sent By jwitmer Date 2022-09-20 Time 11:59 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2023-03-06 Cont ID  
Sent By asangele Date 2023-03-06 Time 14:36 Rev Time 0.00
Received By asangele Date 2023-03-06 Time 14:36 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2023-01-13 Cont ID  
Sent By asangele Date 2023-01-13 Time 11:46 Rev Time 0.00
Received By asangele Date 2023-01-13 Time 11:46 Sent To  
Notes
2023-01-13 11:47:18FAILED
 1/13/2023
  
 SEPARATE PERMIT REQUIRED FOR SIGNAGE WITH ENGINNER TO
 SCALE DRAWINGS.
  
  
 ALEXIS SANGELEER
 PLANNER
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2022-08-18 Cont ID  
Sent By asangele Date 2022-08-18 Time 15:49 Rev Time 0.00
Received By asangele Date 2022-08-18 Time 15:49 Sent To  
Notes
2022-08-18 15:55:34FAILED
 8/18/2022
 PLEASE PROVIDE BUILDINGS HEIGHT
  
  
  
 ALEXIS SANGELEER
 ASSOCIATE PLANNER
 [email protected]