Plan Review Details - Permit 22080644
Plan Review Stops For Permit 22080644
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2022-09-21 Cont ID  
Sent By rmcphers Date 2022-09-21 Time 10:51 Rev Time 0.00
Received By rmcphers Date 2022-09-21 Time 10:51 Sent To  
Notes
2022-09-21 10:51:50INTERIOR DEMO UNDER PERMIT 22080643

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-09-23 Cont ID  
Sent By shill Date 2022-09-23 Time 17:27 Rev Time 0.00
Received By shill Date 2022-09-23 Time 17:27 Sent To  
Notes
2022-09-23 17:34:47PROVISO:
 PLUMBING, GAS, MECHANICAL, AND ROOM PAGES HAVE BEEN
 LOCKED TO PREVENT ISSUANCE. SCOPE UNDER THIS PERMIT IS
 FOR LOBBY, HOSPITALITY AREA, TRELLIS, FIRE PIT/PLANTERS
 - BUILDING AND ELECTRICAL ONLY. PLUMBING, GAS,
 MECHANICAL PLANS AND PERMITS REQUIRED.
 HOSPITALITY ROOM BAR REQUIRES THAT A PORTION OF THE BAR
 BE ACCESSIBLE. A REVISION IS REQUIRED (BAR PLAN TO BE
 REVISED, DETAIL REQUIRED).
 REVIEWS FOR PLUMBING, MECHANICAL WILL BE SENT VIA
 EMAIL. REVIEW FOR BUILDING (ROOM COMMENTS) WILL BE SENT
 VIA EMAIL. REVISE PLANS ACCORDINGLY AND SUBMIT.
 GAS PLAN WAS NOT SUBMITTED FOR THE FIRE PIT AREA,
 PLEASE SUBMIT.
  
 IMPACT FEES WILL BE ASSESSED ON 22080258 (PERMIT WHICH
 INCLUDES CHANGE OF OCCUPANCY). A HOLD HAS BEEN PLACED
 ON CO FOR BOTH BUILDING PERMITS.
  
 THIS PHASED PERMIT IS ISSUED AT APPLICANT'S RISK.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-09-21 Cont ID  
Sent By rmcphers Date 2022-09-21 Time 11:07 Rev Time 0.00
Received By rmcphers Date 2022-09-21 Time 10:48 Sent To  
Notes
2022-09-21 10:48:56CHANGE OF OCCUPANCY
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) ON THE DRAWINGS PLEASE SHOW THAT THIS IS A CHANGE OF
 OCCUPANCY CLASSIFICATION (SHOW EXISTING OCCUPANCY
 CLASSIFICATION AND NEW OCCUPANCY CLASSIFICATION) FBC
 EXISTING 1012
  
 2) PLEASE SHOW THE ACCESSIBLE BAR SEATING FOR THE
 INSIDE BAR IN THE HOSPITALITY ROOM (BAR TOP HEIGHT, TOE
 AND KNEE CLEARANCES ETC.) -
  
 3) THE POOL WILL NEED TO MEET FBC ACCESSIBILITY 242
 ---- FBC E 1012.1.4 ACCESSIBILITY.
 ALL BUILDINGS UNDERGOING A CHANGE OF OCCUPANCY
 CLASSIFICATION SHALL COMPLY WITH SECTION 1012.8. FBC
 1012.8 ACCESSIBILITY.
 EXISTING BUILDINGS THAT UNDERGO A CHANGE OF GROUP OR
 OCCUPANCY CLASSIFICATION SHALL COMPLY WITH THE
 PROVISIONS OF THE FLORIDA BUILDING CODE, ACCESSIBILITY.
  
 4) DRAWING A3-16 SHOWS NEW FLOORING IN ROOM 815 - FOR
 FLOORING OTHER THAN CARPETING - THE FOLLOWING ACUSTICAL
 TEST REPORTS ARE REQUIRED:
  
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90..
 PROVIDE A COPY OF THE TEST REPORT. (A DROP CEILING
 SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING ASSEMBLY
 DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED DROP
 CEILING DESCRIPTION)
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. (A DROP
 CEILING SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING
 ASSEMBLY DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED
 DROP CEILING DESCRIPTION)
  
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS
 ATTACHED TO THE FLOORING)
  
 D. YOU CAN EMAIL ME THE PROPOSED TEST REPORTS TO VERIFY
 THAT THEY ARE TEST REPORTS BEFORE RESUBMITTING TO
 PROJECTDOX ( [email protected] )
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-09-21 Cont ID  
Sent By fgiaquin Date 2022-09-21 Time 21:15 Rev Time 0.00
Received By fgiaquin Date 2022-09-20 Time 23:37 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2023-04-13 Cont ID  
Sent By mpeterso Date 2023-04-13 Time 07:58 Rev Time 0.00
Received By mpeterso Date 2023-04-13 Time 07:58 Sent To  
Notes
2023-04-13 08:00:13LOW VOLTAGE REVIEW PASSED FOR VOICE, DATA, TV, AND
 SPEAKER ONLY. STROBE LIGHT WIRING IS REQUIRED TO BE A
 SEPARATE FIRE ALARM PERMIT. MP

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-09-21 Cont ID  
Sent By pleduc Date 2022-09-21 Time   Rev Time 0.00
Received By pleduc Date 2022-09-20 Time 11:28 Sent To  
Notes
2022-09-21 14:10:54FIRE PROVISO:
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2022-09-23 Cont ID  
Sent By shill Date 2022-09-23 Time 17:51 Rev Time 0.00
Received By shill Date 2022-09-23 Time 17:51 Sent To  
Notes
2022-09-23 17:51:47GAS UNDER SEPARATE SUBMITTAL, NOT INCLUDED IN SCOPE
 (GAS FIRE PITS, A 7-00)

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2022-09-23 Time   Rev Time 0.00
Received By cdecoeur Date 2022-09-19 Time 07:09 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2022-09-23 Cont ID  
Sent By shill Date 2022-09-23 Time 16:30 Rev Time 0.00
Received By shill Date 2022-09-23 Time 16:30 Sent To  
Notes
2022-09-23 16:32:28THIS BUILDING CURRENTLY HAS A C.O. AS AN R2 OCCUPANCY.
 A CHANGE OF OCCUPANCY HAS BEEN SUBMITTED UNDER THIS
 PERMIT:
  
 22080258 APPLIED COM-REMOD 695 S OLIVE AVE TDC DRI WEST
 PALM BEACH LLC INTERIOR RENOVATION CONSTRUCTION IN
 GUESTROOM AND
  
 IMPACT FEES WILL BE ASSESSED EITHER WITH 22080258 OR
 UNDER A REVISION TO THIS PERMIT WHICH WILL INCLUDE THE
 ROOMS.
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-09-21 Cont ID  
Sent By rmcphers Date 2022-09-21 Time 11:07 Rev Time 0.00
Received By rmcphers Date 2022-09-21 Time 11:07 Sent To  
Notes
2022-09-21 11:09:00PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2022-09-23 Cont ID  
Sent By medwards Date 2022-09-23 Time 09:02 Rev Time 0.00
Received By medwards Date 2022-09-23 Time 16:22 Sent To  
Notes
2022-09-23 09:03:03THIS PHASE IS FOR THE LOBBY AND AMMENITY AREA ONLY.
 THERE WERE NO MECHANICAL DRAWINGS SUBMITTED FOR THESE
 AREAS. THE OUTDOOR AIR CALCULATIONS FOR THESE ROOMS
 WILL NEED TO BE PROVIDED SINCE THIS IS A CHANGE OF USE
 AND OCCUPANCY.THE MECHANICAL DRAWING S SUBMITTED ARE
 FOR THE ROOMS WHICH WILL NEED TO BE REVIEWED FOR ENERGY
 CODE REQUIREMENTS UNDER A DIFFERENT REVIEW FOR THE R-1
 CHANGE OF OCCUPANCY.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status N Date 2022-09-23 Cont ID  
Sent By rwbrown Date 2022-09-23 Time 17:03 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
2022-09-23 17:03:22PLUMBING ON ANOTHER PERMIT/PHASE

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-09-22 Cont ID  
Sent By ccole Date 2022-09-22 Time 08:32 Rev Time 0.00
Received By ccole Date 2022-09-21 Time 14:24 Sent To  
Notes
2022-09-22 08:32:471ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22080644
 9/21/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS A-300 & A-30A: PLEASE PROVIDE PLUMBING PLANS
 FOR THE NEW HOSPITALITY BAR IN ACCORDANCE WITH SEC.
 107.3.5.1.3 WPB. PLEASE INCLUDE:
 A) PLUMBING PIPING LAYOUT PLAN AND RISER DRAWINGS.
 B) GREASE WASTE DISPOSAL SYSTEM.
 C) WATER HEATER EQUIPMENT SCHEDULE AND PIPING DIAGRAM.
 D) PLUMBING FIXTURE AND EQUIPMENT SCHEDULE.
  
 2) PLEASE NOTE DISCHARGES FROM GLASSWASHERS, BLENDER
 STATIONS, DUMP SINKS ETC. SHALL DRAIN INTO A GREASE
 INTERCEPTOR PER SEC. 1003.3.1 FBC P. DISCHARGES FROM
 FIXTURES AND APPLIANCES INCLUDING HANDSINKS, ICE
 MAKERS, ICE BINS SHALL DRAIN INTO THE SANITARY.
  
 3) SHEETS A-100, A3-16- A3-30: THE CHANGE OF FROM R2 TO
 R1 REQUIRES COMPLIANCE WITH THE FBC ACCESSIBILITY CODE
 PER SEC. 1006.1 FBC EXISTING BUILDING CODE- 2020.
 PLEASE REFER TO SECS 224.1 & 224.1.1 FBC ACC AND
 INDICATE THE NUMBER OF GUEST ROOMS TO BE PROVIDED WITH
 MOBILITY FEATURES COMPLYING WITH SEC. 806.2.
 A) SEC. 224.5: SHOW COMPLIANCE WITH DISPERSION OF THE
 ACCESSIBLE UNITS WITH MOBILITY FEATURES.
 B) TABLE 224.2: SHOW COMPLIANCE FOR THE MINIMUM NUMBER
 OF ROOMS WITH OR WITHOUT ROLL-IN SHOWERS.
 3) SHEETS A3-16- A3-30: FOR UNITS REQUIRED TO BE IN
 COMPLIANCE WITH SEC. 806.2, PLEASE PROVIDE ENLARGED FBC
 ACC DRAWINGS AND DETAILS INCLUDING:
 A) CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR THE
 WATER CLOSETS- SEC. 604.3.
 B) CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR THE
 LAVATORIES- SEC. 606.2.
 C) TURNING SPACE DIAMETERS- SEC. 304.3.
 D) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED
 FLOORS- SEC. 604.4.
 E) HEIGHTS OF THE MIRRORS FROM THE FINISHED FLOORS TO
 THE REFLECTIVE SURFACES- SEC. 603.3
 F) LENGTHS AND MOUNTING HEIGHTS OF THE SIDE WALL AND
 REAR GRAB BARS FOR THE WATER CLOSETS- SEC. 604.5.
 G) LOCATIONS OF THE WATER CLOSET FLUSH CONTROLS- SEC.
 604.6.
 H) LAVATORY SINKS AND BAR SINKS RIM OR COUNTER HEIGHTS
 AND CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS- SEC.
 606.2. PLEASE INCLUDE ELEVATION VIEWS FOR KNEE AND TOE
 CLEARANCES WHERE FORWARD APPROACHES ARE USED- SECS.
 306.2 & 306.3.
 I) DIMENSIONS OF THE ACCESSIBLE SHOWERS- SEC. 608.2.2.
 J) CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR THE
 ACCESSIBLE SHOWERS- SEC. 608.2.2.
 H) LENGTHS AND SPACING OF GRAB BARS FOR THE ACCESSIBLE
 SHOWERS- SEC. 608.3.2.
 N) LOCATIONS OF CONTROL, FAUCET, AND SHOWER SPRAYS IN
 THE SHOWERS- SEC. 608.5.2.
  
 4) A3-16- A3-30: PROVIDE A SHOWER PAN DETAIL FOR THE
 ROLL-IN SHOWERS- SEC. 608.7 FBC ACC, AND SEC. 421.5.2
 FBC P.
  
 5) P-0.1: PROVIDE A GUEST ROOM PLUMBING FIXTURE
 SCHEDULE THAT INCLUDES THE WATER CLOSETS, LAVATORIES,
 SHOWERS, BAR SINKS, AND THE WT'S- SEC. 404.1 FBC P.
  
 6) P-0.2: DETAIL 2 SHOWS A TANKLESS WATER HEATER UNDER
 A SINK. PLEASE SHOW THE LOCATIONS OF THE WATER HEATERS
 ON THE FLOOR PLANS AND PROVIDE A MEANS OF LIMITING THE
 HOT WATER TEMPERATURE DELIVERY FROM SINKS EQUIPPED WITH
 THE HEATERS- SEC. 607.1.1 FBC P.
  
 7) P3-18- P3-30: PROVIDE BACKFLOW PREVENTERS FOR THE
 WATER SUPPLY LINES TO THE ICE MAKERS- SECS. 608.3 &
 801.2 FBC P.
  
 8) P3-18- P3-30: PLEASE PROVIDE AN EQUIPMENT SCHEDULE
 FOR THE ICE MAKERS AND CLARIFY HOW DRAINAGE FROM THE
 UNITS WILL BE CONVEYED TO AN APPROVED PLACE OF
 DISPOSAL- SEC. 802.1.3 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-09-21 Cont ID  
Sent By rmcphers Date 2022-09-21 Time 11:26 Rev Time 0.00
Received By rmcphers Date 2022-09-21 Time 11:26 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-09-21 Cont ID  
Sent By ckimmerl Date 2022-09-21 Time 12:01 Rev Time 0.00
Received By ckimmerl Date 2022-09-21 Time 12:01 Sent To  
Notes
***NONE***