| Plan Review Stops For Permit 22080613 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2022-08-16 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-08-16 |
Time |
06:45 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-08-16 |
Time |
06:45 |
Sent To |
|
|
| Notes |
| 2022-08-16 06:46:05 | ADDRESS APPROPRIATE FOR PROJECT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-11-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-03 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-11-03 |
Time |
05:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-10-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-05 |
Time |
06:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-09-30 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2022-10-05 06:27:34 | 2ND BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | NOTICE: | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | 1. CORRECTED | | | | | | 2. CORRECTED | | | | | | 3. CORRECTED | | | | | | 4. CORRECTED | | | | | | 5.PROVIDE THE DESIGN PRESSURES FOR NEW ROOFING PER | | | FIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES | | | R301.2.1.1WIND DESIGN REQUIRED. | | | | | | 6.PROVIDE A ROOF SHEATHING FASTENER SCHEDULE PER THE | | | CALCULATED DESIGN PRESSURES. | | | TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING | | | SCHEDULE FOR WOOD STRUCTURAL PANELS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-09-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-09-20 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-09-13 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2022-09-20 12:24:25 | 1ST BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | 1. PROVIDE A SITE PLAN.... | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE | | | AND INCLUDED BOUNDARY LINE SURVEY. | | | | | | 2. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 | | | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | FBC R401.3 SITE DRAINAGE | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | | | | 3.PROVIDE THE FINISH FLOOR ELEVATION NON-FLOOD ZONE | | | R403.1.7.3 FOUNDATION ELEVATION. | | | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION | | | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER | | | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED | | | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 | | | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO | | | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN | | | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF | | | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT | | | ALL LOCATIONS ON THE SITE. | | | | | | 4.PROVIDE A SOILS REPORT. | | | R401.4 SOIL TESTS. | | | WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL | | | SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE, | | | SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE | | | LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL | | | DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE | | | THE SOIL???S CHARACTERISTICS AT A PARTICULAR LOCATION. | | | THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN | | | APPROVED METHOD. | | | FBC1803.2 INVESTIGATIONS REQUIRED. | | | | | | 5.PROVIDE THE DESIGN PRESSURES FOR NEW ROOFING PER | | | FIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES | | | R301.2.1.1WIND DESIGN REQUIRED. | | | | | | 6.PROVIDE A ROOF SHEATHING FASTENER SCHEDULE PER THE | | | CALCULATED DESIGN PRESSURES. | | | TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING | | | SCHEDULE FOR WOOD STRUCTURAL PANELS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-11-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-03 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-11-03 |
Time |
08:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-10-18 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-10-18 |
Time |
15:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-09-02 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-09-02 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2022-09-02 14:53:37 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF SERVICE | | | EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, WIRE AND | | | BREAKER SIZES FOR SERVICE AND FEED TO ANY SUB-PANEL(S). | | | SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM BONDING | | | TERMINATION POINT. NEC 215.5, 230, 250.50, 250.94, | | | 408.30; | | | | | | PROVIDE A LOAD CALCULATION FOR THE SERVICE NOT EACH | | | PANEL. 215.5 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-11-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-03 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-19 |
Time |
16:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-10-18 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-09-23 |
Time |
10:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-09-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-09-20 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-08-15 |
Time |
07:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2023-02-06 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-02-06 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-11-17 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2023-02-03 16:25:50 | RECEIPT MU-2022-052156-0000 - $12,071.20 PAID. SEE | | | RECEIPT UPLOADED AO | | 2022-11-17 07:12:15 | 11/17/22 EMAILED IMPACT FOR REVIEW-AO |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-09-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-09-15 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-09-13 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2022-09-15 17:06:14 | IMPACT FEES | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2022-08-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-22 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-22 |
Time |
17:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2022-10-21 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-21 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-09-26 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-09-26 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-09-26 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-08-23 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-08-23 |
Time |
06:53 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-08-23 |
Time |
06:53 |
Sent To |
|
|
| Notes |
| 2022-08-23 06:54:22 | 1ST PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2017 WPB AMEND - 107.3.5.3 (12.) -- PLEASE SUBMIT A | | | PLUMBING RISER. PLEASE INCLUDE THE SIGNATURE OF THE | | | PERSON WHO DESIGNED THE ISOMETRIC AS A REQUIREMENT OF | | | 107.2.1. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2022-11-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-03 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-11-03 |
Time |
05:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2022-10-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-05 |
Time |
06:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-09-30 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2022-10-05 06:23:22 | PLAN REVIEW ROOFING | | | | | | 2ND ROOFING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | NOTICE: | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: A ROOFING SUB-PERMIT IS REQUIRED. | | | PERMITS - 105.1 REQUIRED. | | | | | | 1. CORRECTED. | | | | | | 2. DESIGNER SHALL SELECT THE INSTALLATION METHOD OF THE | | | ROOF TILE. IF ADHESIVE IS TO BE USED, PROVIDE THE | | | PRODUCT APPROVAL OF THE ADHESIVE. (NOT ADDRESSED) | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | NEW COMMENT: | | | | | | 3.PROVIDE THE FL PRODUCT APPROVALS OR MIAMI-DADE NOA | | | FOR THE PROPOSED HIP AND RIDGE TILE TO BE INSTALLED. | | | FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, | | | EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. | | | NOTE: NOAS DO NOT HAVE COVER SHEETS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-09-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-09-20 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-09-13 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2022-09-20 11:31:22 | PLAN REVIEW ROOFING | | | | | | 1ST ROOFING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: A ROOFING SUB-PERMIT IS REQUIRED. | | | PERMITS - 105.1 REQUIRED. | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR SECONDARY WATER | | | BARRIER PER FBC R905.1.1. | | | UNDERLAYMENT FOR ROOF SLOPES 2:12 AND GREATER SHALL | | | CONFORM TO THE APPLICABLE STANDARDS??? AND SHALL BE | | | APPLIED AND ATTACHED IN ACCORDANCE WITH SECTION | | | R905.1.1.1, R905.1.1.2 OR R905.1.1.3, AS APPLICABLE. | | | | | | R905.3.3UNDERLAYMENT. CONCRETE TILE. | | | REQUIRED UNDERLAYMENT SHALL COMPLY WITH THE | | | UNDERLAYMENT MANUFACTURER???S INSTALLATION INSTRUCTIONS | | | IN ACCORDANCE WITH THE FRSA/TRI FLORIDA HIGH WIND | | | CONCRETE AND CLAY ROOF TILE INSTALLATION MANUAL, SIXTH | | | EDITION WHERE THE VASD IS DETERMINED IN ACCORDANCE WITH | | | SECTION R301.2.1.3 OR THE RECOMMENDATIONS OF RAS 118, | | | 119 OR 120. | | | | | | 2. DESIGNER SHALL SELECT THE INSTALLATION METHOD OF THE | | | ROOF TILE. IF ADHESIVE IS TO BE USED, PROVIDE THE | | | PRODUCT APPROVAL OF THE ADHESIVE. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-11-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-03 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-11-03 |
Time |
05:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-10-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-05 |
Time |
06:30 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-09-30 |
Time |
10:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-09-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-09-20 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-09-13 |
Time |
10:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-10-24 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-10-24 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-10-24 |
Time |
14:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2022-10-04 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-10-04 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-10-04 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2022-10-04 14:19:32 | 10/4/2022 | | | FAILED | | | | | | NEW CONSTRUTIONS ARE REQUIRED TO ALSO MAKE A LANDSCAPE | | | PERMIT PLEASE REACH OUT TO EITHER RAY OR SMITH ARE | | | LANDSCAPE PLANNERS. | | | | | | | | | | | | RAY: 561-822-1462 | | | SMITH: 561-822-1562 | | | | | | ALEXIS SANGELEER | | | ASSOCIATE PLANNER | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-08-29 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-08-29 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-08-29 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2022-08-29 16:44:28 | FAILED | | | 8/29/2022 | | | | | | PLEASE PROVIDE A SURVEY WITH LABELED SETBACKS OF | | | PROPOSED HOME | | | | | | NEW CONSTRUCTIONS ARE REQUIREMENT TO HAVE A LANDSCAPE | | | PERMIT | | | PLEASE GET INTO CONTACT WITH SMITH 561-822-1562 OR RAY | | | 561-822-1462 LANDSCAPE PLANNERS | | | | | | ALEXIS SANGELEER | | | ASSOCIATE PLANNER | | | [email protected] |
|
|