Plan Review Details - Permit 22080570
Plan Review Stops For Permit 22080570
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-04-07 Cont ID  
Sent By rmcdouga Date 2023-04-07 Time 14:53 Rev Time 0.00
Received By rmcdouga Date 2023-04-07 Time 14:53 Sent To  
Notes
2023-04-07 14:53:13PROVISO: THE GATES CAN NOT SWING OUT PAST THE PROPERTY
 LINE. THE GATES SHALL BE SELF-CLOSING AND SELF-LATCHING
 IN COMPLIANCE WITH FBC-R4501.17.1.8

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-09-02 Cont ID  
Sent By rmcdouga Date 2022-09-02 Time 06:26 Rev Time 0.00
Received By rmcdouga Date 2022-09-02 Time 06:00 Sent To  
Notes
2022-09-02 06:26:14PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE GATES CAN NOT SWING OUT PAST THE PROPERTY LINE.
 SEE ENGINEERING COMMENTS.
  
 2) SPECIFY THE DIAMETER OF THE HOLE FOR THE FENCE POST
 THAT WILL BE FILLED WITH CONCRETE. FBC AMENDMENTS
 107.2.1
  
 3) SPECIFY HOW THE GATE LATCH WILL COMPLY WITH
 FBC-R4501.17.1.8. ACCESS GATES, WHEN PROVIDED, SHALL BE
 SELF-CLOSING AND SHALL COMPLY WITH THE REQUIREMENTS OF
 SECTIONS R4501.17.1.1 THROUGH R4501.17.1.7 AND SHALL BE
 EQUIPPED WITH A SELF-LATCHING LOCKING DEVICE LOCATED ON
 THE POOL SIDE OF THE GATE. WHERE THE DEVICE RELEASE IS
 LOCATED NO LESS THAN 54 INCHES (1372 MM) FROM THE
 BOTTOM OF THE GATE, THE DEVICE RELEASE MECHANISM MAY BE
 LOCATED ON EITHER SIDE OF THE GATE AND SO PLACED THAT
 IT CANNOT BE REACHED BY A YOUNG CHILD OVER THE TOP OR
 THROUGH ANY OPENING OR GAP FROM THE OUTSIDE. GATES THAT
 PROVIDE ACCESS TO THE SWIMMING POOL MUST OPEN OUTWARD
 AWAY FROM THE POOL. THE GATES AND BARRIER SHALL HAVE NO
 OPENING GREATER THAN 1/2 INCH (12.7 MM) WITHIN 18
 INCHES (457 MM) OF THE RELEASE MECHANISM.
  
 4) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS.
 ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF
 THE PERSON RESPONSIBLE FOR THE DESIGN.

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2023-04-11 Cont ID  
Sent By lquinone Date 2023-04-11 Time 14:53 Rev Time 0.00
Received By lquinone Date 2023-04-11 Time 14:53 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2022-09-01 Cont ID  
Sent By rrossano Date 2022-09-01 Time   Rev Time 0.00
Received By rrossano Date 2022-09-01 Time   Sent To  
Notes
2022-09-01 12:56:08GATE MAY NOT SWING OUT AND ENCROACH INTO SIDEWALK.
 FENCE CAN BE NOTCHED BACK INTO PROPERTY FOR THE GATE
 AREA, SO THAT WHEN GATE IS OPEN IT DOES NOT ENCROACH
 INTO SIDEWALK.
  
 THANKS,
 RICK ROSSANO, SENIOR PROJECT COORDINATOR, CITY OF WPB
 ENGINEERING SERVICES DEPARTMENT
 EMAIL: [email protected]
 HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGINEERING-
 STANDARDS-DETAILS
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-04-13 Cont ID  
Sent By aoliver Date 2023-04-13 Time 09:14 Rev Time 0.00
Received By aoliver Date 2023-04-04 Time 08:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-09-02 Cont ID  
Sent By vbroglia Date 2022-09-02 Time 06:26 Rev Time 0.00
Received By rmcdouga Date 2022-08-15 Time 06:17 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2023-04-06 Cont ID  
Sent By vbroglia Date 2023-04-06 Time 15:18 Rev Time 0.00
Received By vbroglia Date 2023-04-06 Time 15:18 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2022-08-29 Cont ID  
Sent By vbroglia Date 2022-08-29 Time 13:16 Rev Time 0.00
Received By vbroglia Date 2022-08-29 Time 13:16 Sent To  
Notes
2022-08-29 13:17:5208/29/2022 FAILED
  
 THIS LOT IS A DOUBLE FRONT LOT, MEANING FENCE CANNOT
 MORE THAN 4 FEET ALONG MARTIN AVE AND S. OLIVE AVE
  
 FENCE EXCEEDS MAXIMUM HEIGHT ALLOWABLE. PURSUANT TO THE
 CITY OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT
 REGULATIONS, SECTION 94-302(B)(1):
 MAXIMUM HEIGHT. IN RESIDENTIAL DISTRICTS, NO FENCE OR
 WALL SHALL EXCEED SIX FEET IN HEIGHT WITHIN REQUIRED
 SIDE AND REAR SETBACKS. FENCES OR WALLS SHALL NOT BE IN
 EXCESS OF 48 INCHES IN HEIGHT WITHIN THE REQUIRED FRONT
 SETBACK.
  
 PROVISO: NO FENCE, WALL, OR GATE THAT EXCEEDS 4 FEET IN
 HEIGHT SHALL BE PERMITTED WITHIN THE REQUIRED FRONT
 SETBACK OF 25 FEET.
  
 VALENTINA BROGLIA
 ASSOCIATE PLANNER
 [email protected]
  