| Plan Review Stops For Permit 22080521 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2022-08-16 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-08-16 |
Time |
06:54 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-08-16 |
Time |
06:54 |
Sent To |
|
|
| Notes |
| 2022-08-16 06:55:01 | WORK TO BE DONE ON 1ST FLOOR UPDATED DESCRIPTION TO | | | REFLECT THE FLOOR |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
P |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-10-18 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
P |
Date |
2022-09-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-09-27 |
Time |
17:18 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-09-27 |
Time |
17:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-08-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-08-22 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2022-08-22 17:24:28 | COMMERCIAL ASBESTOS | | | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-10-18 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-10-18 14:08:51 | SHAFTWALL ARE BUILT FLOOR TO CEILING, THEY ARE TO BE | | | BUILT WITH STRUCTURAL METAL STUDS, U415 IS FOR | | | NONBEARING WALL RATING. WHILE NOT TESTED BY UL, THE | | | SYSTEM HAS BEEN TESTED FOR FIRE AND IS COVERED FOR USE | | | THROUGHOUT THE UNITED STATES. THE FIRE TEST NUMBER IS | | | WHI 495-PSH-0154/0167 AND REPORT NUMBER IS AER-09038 | | | AVAILABLE AT WWW.P-E-I.COM.ALSO SEE CAVITY SHAFTWALL | | | SYSTEMS, TECHNICAL DATA FOR MAXIMUM HORIZONTAL SPANS | | | FOR I-STUD ASSEMBLIES 2 HR. FIRE RESTRICTIVE RATING, | | | HORIZONTAL SHAFTWALL DUCT AND CEILING ASSEMBLIES 09 21 | | | 16.23/NGC BUYLINE1100. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-09-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-09-27 |
Time |
17:18 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-09-27 17:18:14 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 22080521 | | | ADD: 1501 BELVEDERE RD 1ST FLOOR COMMON AREAS | | | CONT: VREDEX CONSRUCTION | | | TEL: 561-440-1600 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: TUES. SEPT. 27TH/2022 | | | ACTION: DENIED | | | | | | 1) COMPLIED. | | | | | | 2)COMPLIED. SHEET A0.4 THE FLOOR PLAN THE LIFE SAFETY | | | PLAN SHOWS THE EAST INTERIOR EXIT STAIRWAYS CONTINUING | | | TO THE EXIT BY A 2-HOUR FIRE RATED EXIT PASSEAGE WAY | | | WITH 90- MINUTE OPENING PROTECTIVES. | | | | | | 2A-B) COMPLIED. | | | | | | 2C) 2ND REQUEST. PLEASE REVIEW SHEET M1.2 FOR ALL | | | DUCTWORK AND RELATED MECHANICAL EQUIPMENT THAT IS | | | LOCATED IN THE CEILINGS OF BOTH THE EAST EXIT | | | PASSAGEWAY. PLEASE REVIEW SECTION 1024.6 PENETRATIONS | | | INTO OR THROUGH EXIT PASSAGEWAYS, PROHIBITED, PLUMBING, | | | MECHANICAL EQUIPMENT, AND ELECTRICAL PIPING AND | | | DEVICES. 2020 FBC-BUILDING. THE RESPONSE THE ENGINEER | | | HAS ADDED A 2- HOUR SHAFT WALL CEILING DETAIL TO | | | CONCEAL THE DUCTWORK. SHAFTWALL ARE BUILT FLOOR TO | | | CEILING, THEY ARE TO BE BUILT WITH STRUCTURAL METAL | | | STUDS, U415 IS FOR NONBEARING WALL RATING. WHILE NOT | | | TESTED BY UL, THE SYSTEM HAS BEEN TESTED FOR FIRE AND | | | IS COVERED FOR USE THROUGHOUT THE UNITED STATES. THE | | | FIRE TEST NUMBER IS WHI 495-PSH-0154/0167 AND REPORT | | | NUMBER IS AER-09038 AVAILABLE AT WWW.P-E-I.COM.ALSO SEE | | | CAVITY SHAFTWALL SYSTEMS, TECHNICAL DATA FOR MAXIMUM | | | HORIZONTAL SPANS FOR I-STUD ASSEMBLIES 2 HR. FIRE | | | RESTRICTIVE RATING, HORIZONTAL SHAFTWALL DUCT AND | | | CEILING ASSEMBLIES 09 21 16.23/NGC BUYLINE1100. PROVIDE | | | A SHAFTWALL ASSEMBLY THAT HAS A 2 HOUR FIRE RATING | | | WHERE IT HAS BEEN TESTED HORIZONTALLY. | | | | | | 2D-E) COMPLIED. | | | | | | 3)COMPLIED. | | | | | | 4) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ SEMI-RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-08-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-08-23 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-08-22 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2022-08-23 11:49:31 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 22080521 | | | ADD: 1501 BELVEDERE RD 1ST FLOOR COMMON AREAS | | | CONT: VREDEX CONSRUCTION | | | TEL: 561-440-1600 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. AUGUST 23/2022 | | | ACTION: DENIED | | | | | | 1) SHEET A0.0 THE COVERSHEET: | | | 1A) PROJECT DATA LIST THIS BUILDING AS 4 STORIES. PALM | | | BEACH COUNTY MY GEO NAV SHOWS A 5 STORY BUILDING AND | | | VIEWING THE BUILDING FROM THE WEST A BASEMENT/ ENCLOSED | | | PARKING LEVEL. ADDITIONAL INFORMATION REQUIRED, | | | 107.2.1. DISCREPANCY IN PLANS. | | | | | | 1B) THE EAST STAIR ENCLOSURE SHOWS THE STAIRS GOING | | | DOWN INTO THE BASEMENT/ GARAGE LEVEL. MISSING ON THE | | | WEST STAIR ENCLOSURE. ADDITIONAL INFORMATION REQUIRED, | | | 107.2.1. DISCREPANCY IN PLANS. | | | | | | 2) SHEET A0.4 THE FLOOR PLAN DETAIL ON THE COVERSHEET | | | AND LIFE SAFETY PLAN SHOWS BOTH THE EAST AND WEST | | | INTERIOR EXIT STAIRWAYS CONTINUING TO THE EXIT BY A 2 | | | HOUR FIRE RATED EXIT PASSAGE WAY, INCLUSIVE OF THE | | | LOBBY AREA. | | | 2A) PLEASE REVIEW IN THE 2020 FBC-BUILDING CODE SECTION | | | 1024.5OPENINGS. REVIEW THE LAST LINE, ELEVATORS SHALL | | | NOT OPEN INTO EXIT PASSAGEWAYS. | | | | | | 2B) THE LOBBY WALLS AND CORRIDOR ARE CURRENTLY SHOWN AS | | | 2 HOUR EXIT PASSAGE WAY RATED WALLS, BUT THE OPENINGS | | | LEADING TO THE RESTROOM CORRIDOR 109 DO NOT HAVE | | | OPENING PROTECTIVE DOORS RATED 1 1/2 HRS. AS REQUIRED | | | BY TABLE 716.5 IF THIS AREA REMAINED A 2HOUR EXIT | | | PASSAGEWAY. | | | | | | 2C) PLEASE REVIEW SHEET M1.2 FOR ALL DUCTWORK AND | | | RELATED MECHANICAL EQUIPMENT THAT IS LOCATED IN THE | | | CEILINGS OF BOTH THE EAST AND WEST EXIT PASSAGEWAYS. | | | PLEASE REVIEW SECTION 1024.6 PENETRATIONS INTO OR | | | THROUGH EXIT PASSAGEWAYS, PROHIBITED, PLUMBING, | | | MECHANICAL EQUIPMENT, AND ELECTRICAL PIPING AND | | | DEVICES. 2020 FBC-BUILDING. | | | | | | 2D) THERE ARE NO WALL IDENTIFICATION TAGS IN THE EXIT | | | PASSAGEWAY INDICATING THESE WALLS ARE 2-HOUR FIRE | | | RESISTANCE RATING. 2-HOUR VERTICAL EXITS, INTERIOR EXIT | | | STAIRWAYS, REQUIRE THE EXIT PASSAGEWAY TO MAINTAIN THE | | | SAME LEVEL OF FIRE RATING (FIRE BARRIERS) SECTION | | | 1023.2 & 1024.3. | | | | | | 2E) THE EAST INTERIOR EXIT DOOR SWINGS INTO THE EXIT | | | RATHER THAN SWINGING OUT AS THE DIRECTION OF EGRESS | | | TRAVEL PER 1010.1.2.1. THE DOOR WOULD NEED TO BE FITTED | | | WITH 180 DEGREE HINGES TO SWING FLAT AGAINST THE WALL. | | | 3) SHEET A3.2 WALL DETAILS DO NOT INCLUDE A UL WALL | | | ASSEMBLY FOR A 2 HOUR FIRE RESISTANCE RATED WALL.2020 | | | FBC-BUILDING CODE SECTION 707.3.4 EXIT PASSAGEWAYS. | | | | | | 4) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ SEMI-RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-08-17 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-08-17 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-08-16 |
Time |
23:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-09-26 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-09-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-09-26 09:44:19 | FIRE PROVISO COMMENTS: | | | | | | ALL LIFE SAFETY SYSTEMS (FIRE SPRINKLER AND/OR FIRE | | | ALARM) SHALL REMAIN FULLY OPERATIONAL DURING ALL PHASES | | | OF DEMOLITION AND CONSTRUCTION. | | | | | | ANY IMPAIRMENT TO ANY LIFE SAFETY SYSTEM (FIRE | | | SPRINKLER AND/OR FIRE ALARM) THAT EXCEEDS 4 CONTINUOUS | | | HOURS IN DURATION WILL REQUIRE THE IMPLEMENTATION OF A | | | FIRE WATCH. | | | | | | ANY WORK (RELOCATION, MODIFICATIONS, ETC.) ON ANY LIFE | | | SAFETY SYSTEM (FIRE SPRINKLER AND/OR FIRE ALARM) WILL | | | REQUIRE SEPARATE PERMITS AND SHOP DRAWINGS. | | | | | | ANY WORK ON ANY LIFE SAFETY SYSTEM (FIRE SPRINKLER | | | AND/OR FIRE ALARM) SHALL BE DONE BY PROPERLY LICENSED | | | AND QUALIFIED CONTRACTORS. | | | | | | C. WALKER | | | | | | 561-804-4762 | | | | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-08-17 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-08-17 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-08-17 11:11:00 | FIRE PROVISO COMMENTS: | | | | | | ALL LIFE SAFETY SYSTEMS (FIRE SPRINKLER AND/OR FIRE | | | ALARM) SHALL REMAIN FULLY OPERATIONAL DURING ALL PHASES | | | OF DEMOLITION AND CONSTRUCTION. | | | | | | ANY IMPAIRMENT TO ANY LIFE SAFETY SYSTEM (FIRE | | | SPRINKLER AND/OR FIRE ALARM) THAT EXCEEDS 4 CONTINUOUS | | | HOURS IN DURATION WILL REQUIRE THE IMPLEMENTATION OF A | | | FIRE WATCH. | | | | | | ANY WORK (RELOCATION, MODIFICATIONS, ETC.) ON ANY LIFE | | | SAFETY SYSTEM (FIRE SPRINKLER AND/OR FIRE ALARM) WILL | | | REQUIRE SEPARATE PERMITS AND SHOP DRAWINGS. | | | | | | ANY WORK ON ANY LIFE SAFETY SYSTEM (FIRE SPRINKLER | | | AND/OR FIRE ALARM) SHALL BE DONE BY PROPERLY LICENSED | | | AND QUALIFIED CONTRACTORS. | | | | | | C. WALKER | | | | | | 561-804-4762 | | | | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-10-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-10-06 |
Time |
07:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-09-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-09-27 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-09-23 |
Time |
09:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-08-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
cdecoeur |
Date |
2022-08-15 |
Time |
09:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2022-08-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-08-23 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-08-22 |
Time |
17:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-10-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-10-07 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-07 |
Time |
08:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-09-27 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-27 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-27 |
Time |
17:03 |
Sent To |
|
|
| Notes |
| 2022-09-27 17:04:22 | 2ND REVIEW FMC | | | PERMIT: 22080521 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 2ND ATTEMPT FOR THE COMMENTS BELOW. THE AREA LEADING | | | FROM THE STAIRWAY TO THE EAST SIDE OF THE BUILDING IS | | | AN EXIT PASSAGEWAY BY DEFINITION. FBC EXIT PASSAGEWAY. | | | AN EXIT COMPONENT THAT IS SEPARATED FROM OTHER INTERIOR | | | SPACES OF A BUILDING OR STRUCTURE BY FIRE-RESISTANCE- | | | RATED CONSTRUCTION AND OPENING PROTECTIVES, AND | | | PROVIDES FOR A PROTECTED PATH OF EGRESS TRAVEL IN A | | | HORIZONTAL DIRECTION TO AN EXIT OR TO THE EXIT | | | DISCHARGE. | | | THERE CAN BE NOTHING IN OR PASSING THROUGH THIS EXIT | | | PASSAGEWAY. THE VAV-16 MUST BE REMOVED. THERE CAN BE NO | | | RETURN, OR SUPPLY GRILLES PENETRATING THE RATED | | | CEILING. IF THIS EXIT PASSAGEWAY IS TO BE CONDITIONED | | | IT MUST BE CONDITIONED INDEPENDENTLY FROM THE BUILDINGS | | | MECHANICAL SYSTEMS. 2ND ATTEMPT FOR THE COMMENTS BELOW. | | | ORIGINAL REVIEW COMMENTS: | | | | | | 1) THE REDESIGN OF THE OPEN AREA OF THE 1ST FLOOR INTO | | | TENANT SPACES HAS CREATED EXIT PASSAGEWAYS. PLEASE | | | REMOVE ALL DUCTWORK AND SYSTEMS FROM THESE EXIT | | | PASSAGEWAYS. FMC 601.3 | | | [BF] 601.3 EXITS. EQUIPMENT AND DUCTWORK FOR EXIT | | | ENCLOSURE VENTILATION SHALL COMPLY WITH ONE OF THE | | | FOLLOWING ITEMS: | | | | | | 1. SUCH EQUIPMENT AND DUCTWORK SHALL BE LOCATED | | | EXTERIOR TO THE BUILDING AND SHALL BE DIRECTLY | | | CONNECTED TO THE EXIT ENCLOSURE BY DUCTWORK ENCLOSED IN | | | CONSTRUCTION AS REQUIRED BY THE FLORIDA BUILDING CODE, | | | BUILDING FOR SHAFTS. | | | | | | 2. WHERE SUCH EQUIPMENT AND DUCTWORK IS LOCATED WITHIN | | | THE EXIT ENCLOSURE, THE INTAKE AIR SHALL BE TAKEN | | | DIRECTLY FROM THE OUTDOORS AND THE EXHAUST AIR SHALL BE | | | DISCHARGED DIRECTLY TO THE OUTDOORS, OR SUCH AIR SHALL | | | BE CONVEYED THROUGH DUCTS ENCLOSED IN CONSTRUCTION AS | | | REQUIRED BY THE FLORIDA BUILDING CODE, BUILDING FOR | | | SHAFTS. | | | | | | 3.WHERE LOCATED WITHIN THE BUILDING, SUCH EQUIPMENT AND | | | DUCTWORK SHALL BE SEPARATED FROM THE REMAINDER OF THE | | | BUILDING, INCLUDING OTHER MECHANICAL EQUIPMENT, WITH | | | CONSTRUCTION AS REQUIRED BY THE FLORIDA BUILDING CODE, | | | BUILDING FOR SHAFTS. | | | | | | | | | IN EACH CASE, OPENINGS INTO FIRE-RESISTANCE-RATED | | | CONSTRUCTION SHALL BE LIMITED TO THOSE NEEDED FOR | | | MAINTENANCE AND OPERATION AND SHALL BE PROTECTED BY | | | SELF-CLOSING FIRE-RESISTANCE- RATED DEVICES IN | | | ACCORDANCE WITH THE FLORIDA BUILDING CODE, BUILDING FOR | | | ENCLOSURE WALL OPENING PROTECTIVES. EXIT ENCLOSURE | | | VENTILATION SYSTEMS SHALL BE INDEPENDENT OF OTHER | | | BUILDING VENTILATION SYSTEMS. | | | | | | 2) THE OUTDOOR AIR CALCULATIONS MUST MEET FMC 403.3.1.1 | | | AND TABLE 403.3.1.1. BASED ON THE OCCUPANCY AND SQUARE | | | FOOTAGE IN THE OUTDOOR AIR CALCULATIONS PRESENTED ON | | | SHEET M1.2 THE LOBBY IS REQUIRED TO HAVE 1031 CFM???S | | | OF OUTDOOR AIR; THE MAIL ROOM IS NOT AN OCCUPANCY | | | LISTED IN TABLE 403.3.1.1, PLEASE USE AN OCCUPANCY | | | LISTED IN THE TABLE THAT CLOSELY RESEMBLES THE USE LIKE | | | MAYBE THE STORAGE, PICK UP; THE ENTRANCE/EXIT IS ALSO | | | NOT AN OCCUPANCY LISTED IN TABLE 403.3.1.1, PLEASE PICK | | | AN OCCUPANCY THAT BEST MEETS THE REQUIREMENTS AND | | | PROVIDE CALCULATIONS BASED ON THAT OCCUPANCY. FMC | | | 403.3.1.1 AND TABLE 403.3.1.1. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-08-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-22 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-22 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2022-08-22 11:02:28 | 1ST REVIEW FMC | | | PERMIT: 22080521 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE REDESIGN OF THE OPEN AREA OF THE 1ST FLOOR INTO | | | TENANT SPACES HAS CREATED EXIT PASSAGEWAYS. PLEASE | | | REMOVE ALL DUCTWORK AND SYSTEMS FROM THESE EXIT | | | PASSAGEWAYS. FMC 603.1 | | | [BF] 601.3 EXITS. EQUIPMENT AND DUCTWORK FOR EXIT | | | ENCLOSURE VENTILATION SHALL COMPLY WITH ONE OF THE | | | FOLLOWING ITEMS: | | | | | | 1. SUCH EQUIPMENT AND DUCTWORK SHALL BE LOCATED | | | EXTERIOR TO THE BUILDING AND SHALL BE DIRECTLY | | | CONNECTED TO THE EXIT ENCLOSURE BY DUCTWORK ENCLOSED IN | | | CONSTRUCTION AS REQUIRED BY THE FLORIDA BUILDING CODE, | | | BUILDING FOR SHAFTS. | | | | | | 2. WHERE SUCH EQUIPMENT AND DUCTWORK IS LOCATED WITHIN | | | THE EXIT ENCLOSURE, THE INTAKE AIR SHALL BE TAKEN | | | DIRECTLY FROM THE OUTDOORS AND THE EXHAUST AIR SHALL BE | | | DISCHARGED DIRECTLY TO THE OUTDOORS, OR SUCH AIR SHALL | | | BE CONVEYED THROUGH DUCTS ENCLOSED IN CONSTRUCTION AS | | | REQUIRED BY THE FLORIDA BUILDING CODE, BUILDING FOR | | | SHAFTS. | | | | | | 2. WHERE LOCATED WITHIN THE BUILDING, SUCH EQUIPMENT | | | AND DUCTWORK SHALL BE SEPARATED FROM THE REMAINDER OF | | | THE BUILDING, INCLUDING OTHER MECHANICAL EQUIPMENT, | | | WITH CONSTRUCTION AS REQUIRED BY THE FLORIDA BUILDING | | | CODE, BUILDING FOR SHAFTS. | | | | | | IN EACH CASE, OPENINGS INTO FIRE-RESISTANCE-RATED | | | CONSTRUCTION SHALL BE LIMITED TO THOSE NEEDED FOR | | | MAINTENANCE AND OPERATION AND SHALL BE PROTECTED BY | | | SELF-CLOSING FIRE-RESISTANCE- RATED DEVICES IN | | | ACCORDANCE WITH THE FLORIDA BUILDING CODE, BUILDING FOR | | | ENCLOSURE WALL OPENING PROTECTIVES. EXIT ENCLOSURE | | | VENTILATION SYSTEMS SHALL BE INDEPENDENT OF OTHER | | | BUILDING VENTILATION SYSTEMS. | | | | | | 2) PROVIDE THE DETAIL FOR THE RATED WALLS AS THEY ARE | | | NOT ON THE DRAWINGS. FBC 107.3.5 | | | | | | 3) PROVIDE THE OUTDOOR AIR CALCULATIONS FOR EACH USE OF | | | SPACE. FMC 403.3.1.1 AND TABLE 403.3.1.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-08-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-16 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-16 |
Time |
12:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-10-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-10-07 08:07:45 | MECHANICAL DIGITAL SIGNATURES APPROVED ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-09-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-09-27 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-09-27 17:09:33 | MECHANICAL DIGITAL SIGNATURES APPROVED ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-08-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-08-23 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-08-22 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2022-08-22 11:03:36 | DIGITAL SIGNATURES FOR MECHANICAL APPROVED ME |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-08-19 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-08-19 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-08-19 |
Time |
13:44 |
Sent To |
|
|
| Notes |
|
|