Plan Review Details - Permit 22080461
Plan Review Stops For Permit 22080461
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-10-13 Cont ID  
Sent By cpuell Date 2022-10-13 Time 16:37 Rev Time 0.00
Received By cpuell Date 2022-10-13 Time 16:37 Sent To  
Notes
2022-10-13 16:39:33ADDRESS CORRECT FOR THIS TENANT SPACE. HOWEVER THE FIRE
 SAFETY PLAN DOES NOT HAVE THE CORRECT SUITE ADDRESS
 CONFIGURATIONS.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2022-11-08 Cont ID  
Sent By jwitmer Date 2022-11-08 Time 16:02 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
2022-11-08 16:02:26MASTER SHELL PERMIT21051228. 1ST OCCUPANCY.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-11-29 Cont ID  
Sent By jwitmer Date 2022-11-29 Time 09:39 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-11-08 Cont ID  
Sent By rmcdouga Date 2022-11-08 Time 15:59 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-11-08 15:59:05WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING AUDIT
 W. P. B. PERMIT: 22080461
 ADD: 424 PARK PL. # 101
 CONT: J SCOTT DEVELOPMENT CO
 TEL: 954-914-6380
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. NOV. 08TH/2022
 ACTION: DENIED
  
 1) SHEET A-1.2 THE RESTROOM FLOOR PLAN SHOWS TOILET
 PAPER DISPENSERS MOUNTED TO THE COMMON WALL OF THE
 RESTROOMS. THE NORTH WALL ELEVATIONS OF BOTH RESTROOMS
 WOMEN???S AND MEN???S ARE MISSING THE TOILET PAPER
 DISPENSER LOCATIONS.
 2020 FBC-ACCESSIBILITY CODE SECTION TOILET PAPER
 DISPENSERS. 604.7. THE TOILET PAPER DISPENSER SHALL
 COMPLY WITH 309.4 AND SHALL BE 7 INCHES MINIMUM TO 9
 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER.
 THE OUTLET OF THE DISPENSER SHALL BE 15 INCHES MINIMUM
 AND 48 INCHES MAXIMUM ABOVE THE FINISH FLOOR AND SHALL
 NOT BE LOCATED BEHIND THE GRAB BARS.
  
 2) SHEET A-1.2 THE FLOOR PLAN AND ELEVATIONS ALL SHOW
 WALL TILE ON THE RESTROOM WALLS, WOMEN???S, MEN???S AND
 STAFF. THE PLANS DO NOT INDICATE THE WALL TYPE NOR
 THICKNESS OF THE BACKER BOARD FOR THE WALL TILE.
 2020 FBC-B 2509.2 BASE FOR TILE. MATERIALS USED AS A
 FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN
 INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C840 AND
 THE MANUFACTURE???S RECOMMENDATIONS.
  
 3) SHEET A-1.0 MOP SINK BASIN IS IDENTIFIED WITH THE
 LETTER (J). THE PLANS DO NOT INDICATE THE WALL TYPE NOR
 THICKNESS OF THE BACKER BOARD FOR THE WALL TILE.
 2020 FBC-B 2509.2 BASE FOR TILE. MATERIALS USED AS A
 FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN
 INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C840 AND
 THE MANUFACTURE???S RECOMMENDATIONS.
  
 4) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-10-31 Cont ID  
Sent By mpeterso Date 2022-10-31 Time 10:20 Rev Time 0.00
Received By mpeterso Date 2022-10-31 Time 10:20 Sent To  
Notes
2022-10-31 10:21:02AUDIT OF ELECTRICAL PALNS PASSED. MP

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-11-29 Cont ID  
Sent By pleduc Date 2022-11-29 Time   Rev Time 0.00
Received By pleduc Date 2022-11-29 Time 10:56 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-10-04 Cont ID  
Sent By pleduc Date 2022-10-04 Time   Rev Time 0.00
Received By pleduc Date 2022-10-04 Time 11:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-12-05 Cont ID  
Sent By pvalenti Date 2022-12-05 Time 15:47 Rev Time 0.00
Received By pvalenti Date 2022-11-28 Time 08:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2022-11-08 Time   Rev Time 0.00
Received By shill Date 2022-10-18 Time 11:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2022-10-18 Time   Rev Time 0.00
Received By cdecoeur Date 2022-09-30 Time 05:29 Sent To  
Notes
2022-10-11 09:16:50ADD BME AFTER ZONING (ASSIGN B TO RMCD)
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-12-14 Cont ID  
Sent By lmarchan Date 2022-12-14 Time 15:59 Rev Time 0.00
Received By lmarchan Date 2022-12-06 Time 16:28 Sent To  
Notes
2022-12-12 11:43:02RECEIPT MU-2022-054339 - $17,613.57 PAID
2022-12-06 16:29:2012/06/2022 IMPACT FEE QUEST UPLOADED. PBCGOV EMAILED AO

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-11-08 Cont ID  
Sent By jwitmer Date 2022-11-08 Time 16:03 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
2022-11-08 16:03:16IMPACT FEES - DIGITAL SUBMITTALS:
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected].
 PALM BEACH COUNTY IMPACT FEE OFFICE IS LOCATED AT 2300
 N. JOG RD. ROOM???S 2W01-2W14 WEST PALM BEACH, FL.
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-12-05 Cont ID  
Sent By pvalenti Date 2022-12-05 Time 15:45 Rev Time 0.00
Received By pvalenti Date 2022-12-05 Time 13:06 Sent To  
Notes
2022-12-05 15:46:47PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 MECHANICAL AUDIT OK

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-10-21 Cont ID  
Sent By medwards Date 2022-10-21 Time 06:15 Rev Time 0.00
Received By medwards Date 2022-10-21 Time 06:15 Sent To  
Notes
2022-10-21 06:16:19 
 1ST AUDIT FMC
 PERMIT: 22080461
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PRIVATE PROVIDER AUDIT RESULTS: DENIED.
  
 1) THERE IS NOT ENOUGH INFORMATION IN THIS SUBMITTAL
 FOR THIS REVIEWER TO DO A COMPLETE AUDIT FOR THE
 PROJECT.
  
 2) PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS
 FOR THIS NEW RESTAURANT. FEC C403.2.1
  
 3) SHEET M801: REMOVE NOTE 3 FROM THE NOTES IN THE
 OUTDOOR AIR CALCULATIONS AND PROVIDE THE REQUIRED
 OUTDOOR AIR CALCULATIONS FOR THIS TENANT SPACE ON THE
 OUTDOOR AIR CALCULATIONS CHART. FMC 403.3.1.1 AND TABLE
 403.3.1.1
  
 4) THE MASTER PERMIT 21051228, SHEET M1.01 INDICATES
 THAT TENANT SPACE 1 TAKES THE ENTIRE RIGHT SIDE OF THIS
 AREA OF THE BUILDING. SHEET M1.01 OF PERMIT 21051228
 INDICATES ONLY 1 RTU FOR THIS SIDE OF THE BUILDING AND
 IT IS NOT LOCATED IN THE AREA THAT KONRO RESTAURANT???S
 PERMIT 22080461 IS LOCATED. THE RTU IN THIS SUBMITTAL
 IS THEREFORE NOT AN EXISTING RTU. THE DOCUMENTS
 SUBMITTED WITH THIS PERMIT APPLICATION ARE FOR THE
 FRONT AREA OF TENANT SPACE 1. SHEET M801 OF THE
 SUBMITTED DOCUMENTS FOR THIS PROJECT INDICATES AN
 EXISTING RTU-1 THE PLANS SUBMITTED FOR THIS PROJECT
 WILL NEED TO MATCH THE MASTER PERMIT LISTED ABOVE OR
 REVISE PERMIT 21051228 TO INDICATE THE NEW ARRANGEMENT
 OF SPACE IN THIS BUILDING. FBC 107.3.5
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-12-05 Cont ID  
Sent By rwbrown Date 2022-12-05 Time 07:01 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-10-21 Cont ID  
Sent By rwbrown Date 2022-10-21 Time 07:59 Rev Time 0.00
Received By rwbrown Date 2022-10-21 Time 07:59 Sent To  
Notes
2022-10-21 08:02:561ST PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FPC - 607.1.1 TEMPERATURE LIMITING MEANS - ALL
 HOT/TEMPERED WATER MUST BE LIMITED BY A MIXING DEVICE.
 THE THERMOSTAT CONTROL ON THE WATER HEATER CANNOT BE
 THE LIMITING DEVICE FOR HOT/TEMPERED WATER DELIVERY.
 PLEASE PROVIDE A DETAIL FOR A LIMITING DEVICE FOR THE
 PURPOSE OF HOT WATER DELIVERY. THIS WOULD BE IN
 ADDITION TO THE REQUIREMENTS FOR TEMPERED WATER
 SUPPLIED FOR PUBLIC HANDWASHING 607.1.2/419.5. ALSO,
 THE DEVICE SHALL MEET THE ASSE 1017 STANDARD AND BE
 INSTALLED AT THE HOT WATER SOURCE PER 613.1. PLEASE
 INCLUDE DETAILS THAT SHOW A MIXING VALVE ABOVE THE
 WATER HEATER THAT REGULATES ALL HOT/TEMPERED WATER.
  
 2. 2020 FPC 905.4 - PAGE P701 DETAIL #14 - EVEN THOUGH
 THIS DETAIL IS NOT USED, PLEASE REMOVE AS IT IS NOT TO
 CODE. DRY VENTS ARE NOT ALLOWED TO BE HORIZONTAL UNTIL
 AT LEAST 6 INCHES ABOVE THE FLOOD RIM OF THE FIXTURE
 SERVED. THE ONLY EXCEPTION TO THAT IS VENTS REQUIRED
 FOR EXTERIOR GREASE TRAPS.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status P Date 2022-11-29 Cont ID  
Sent By jwitmer Date 2022-11-29 Time 09:39 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2022-10-20 Cont ID  
Sent By medwards Date 2022-10-20 Time 16:06 Rev Time 0.00
Received By medwards Date 2022-10-20 Time 16:06 Sent To  
Notes
2022-10-20 16:08:09PRIVATE PROVIDER AFFIDAVIT AUDIT ONLY APPROVED ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-12-05 Cont ID  
Sent By rwbrown Date 2022-12-05 Time 07:29 Rev Time 0.00
Received By rwbrown Date 2022-12-05 Time 07:29 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-10-21 Cont ID  
Sent By medwards Date 2022-10-21 Time 07:47 Rev Time 0.00
Received By medwards Date 2022-10-21 Time 07:47 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-10-18 Cont ID  
Sent By vbroglia Date 2022-10-18 Time 16:07 Rev Time 0.00
Received By vbroglia Date 2022-10-18 Time 16:07 Sent To  
Notes
***NONE***