Plan Review Details - Permit 22080280
Plan Review Stops For Permit 22080280
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-10-25 Cont ID  
Sent By jwitmer Date 2022-10-25 Time 07:46 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-10-25 07:46:06THIS UNIT 1ST FLOOR NO SOUND REQUIRED, WPB AMENDMENT
 105.2(2) CRITICAL RADIANT FLUX IS REQUIRED, 2020
 FBC-BUILDING CODE 804.4.4.1 SOFT FLOOR FINISHES. JW
 10/25/2022

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-10-19 Cont ID  
Sent By jwitmer Date 2022-10-19 Time 11:11 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-10-19 11:11:39WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22080280
 ADD: 300 S AUSTRALIAN AVE. # 129
 CONT: SOLID ROCK RENOVATION
 TEL: 561577-3057
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. SEPT. 28TH/ 2022
 ACTION: DENIED
  
 1) COMPLIED.
  
 2) 2ND REQUEST. FBC-B 804.4.4.1 SOFT FLOOR FINISHES
 (LVT/ LPT OR LAMINATED OR ENGINEERED WOOD FLOORING)
 WITHIN TENANT SPACE. INTERIOR FLOOR COVERING MATERIALS
 SHALL COMPLY WITH THE REQUIREMENTS OF THE COC FF-1 PILL
 TEST (CPSC 16 CFR PART 1630) OR WITH ASTM D2859.
  
 3) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-09-28 Cont ID  
Sent By jwitmer Date 2022-09-28 Time 08:24 Rev Time 0.00
Received By jwitmer Date 2022-09-28 Time 08:09 Sent To  
Notes
2022-09-28 08:24:05WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22080280
 ADD: 300 S AUSTRALIAN AVE. # 129
 CONT: SOLID ROCK RENOVATION
 TEL: 561577-3057
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. SEPT. 28TH/ 2022
 ACTION: DENIED
  
 1) THERE IS NO FLOOR PLAN FOR THE NEW FLOORING SHOWING
 THE AREA OF THE FLOOR, SIZE OF AREA OR TYPE OF FLOORING
 TO BE INSTALLED. ADDITIONAL INFORMATION IS REQUIRED.
 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.2.1.
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN
 THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC TO THE TECHNICAL CODES.
 CONSTRUCTION DOCUMENTS SHALL BE SUFFICIENT CLARITY TO
 INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
 2) FBC-B 804.4.4.1 SOFT FLOOR FINISHES (LVT/ LPT OR
 LAMINATED OR ENGINEERED WOOD FLOORING) WITHIN TENANT
 SPACE. INTERIOR FLOOR COVERING MATERIALS SHALL COMPLY
 WITH THE REQUIREMENTS OF THE COC FF-1 ???PILL TEST???
 (CPSC 16 CFR PART 1630) OR WITH ASTM D2859.
  
 3) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-10-25 Cont ID  
Sent By cwalker Date 2022-10-25 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2022-10-17 Cont ID  
Sent By cwalker Date 2022-10-17 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
2022-10-17 10:57:41FIRE REVIEW COMMENTS:
  
 PROVIDE THE FIRE PERFORMANCE OF THE FINISHED FLOOR AND
 THE UNDERLAYMENT MATERIAL TO INCLUDE THE CRITICAL
 RADIANT FLUX OF THE MATERIALS. NFPA 101, 10.2.7
  
 C. WALKER
  
 561-804-4762
  
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-08-22 Cont ID  
Sent By cwalker Date 2022-08-22 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
2022-08-22 12:40:38FIRE REVIEW COMMENTS:
  
 THE APPLICATION INDICATES NEW FLOORING.
  
 THERE WERE NO SPECIFICATIONS PROVIDED ON THE TYPE OF
 FINISHED FLOORING AND THE UNDERLAYMENT MATERIAL.
  
 PROVIDE SPECIFICATIONS AND THE PROPOSED FLOORING AND
 UNDERLAYMENT OF THE MATERIALS FIRE PERFORMANCE
 INCLUDING THE CRITICAL RADIANT FLUX OF ALL FLOORING
 MATERIALS. NFPA 101, 10.2.7
  
 C. WALKER
  
 561-804-4762
  
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-10-26 Cont ID  
Sent By aoliver Date 2022-10-26 Time 08:07 Rev Time 0.00
Received By aoliver Date 2022-10-24 Time 15:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-10-19 Cont ID  
Sent By jwitmer Date 2022-10-19 Time 11:11 Rev Time 0.00
Received By jwitmer Date 2022-10-13 Time 08:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-09-28 Cont ID  
Sent By jwitmer Date 2022-09-28 Time 08:25 Rev Time 0.00
Received By jwitmer Date 2022-08-22 Time 05:35 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2022-09-28 Cont ID  
Sent By jwitmer Date 2022-09-28 Time 08:24 Rev Time 0.00
Received By jwitmer Date 2022-09-28 Time 08:09 Sent To  
Notes
***NONE***