Plan Review Details - Permit 22080233
| Plan Review Stops For Permit 22080233 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2022-09-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-09-16 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-09-16 |
Time |
07:09 |
Sent To |
|
|
| Notes |
| 2022-09-16 07:28:44 | FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND | | | BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO | | | FILLING THE POOL WITH WATER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-10-24 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-10-24 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-10-24 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-08-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-08-14 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-08-14 |
Time |
17:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2022-08-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-17 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-17 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2022-08-17 14:55:08 | THE POOL HEATER GAS PIPING SHALL BE INSTALLED UNDER A | | | SEPARATE PERMIT. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-08-16 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-08-16 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-08-16 |
Time |
13:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-10-24 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-10-24 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-10-13 |
Time |
08:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-09-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-09-16 |
Time |
07:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-08-09 |
Time |
06:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-10-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-10-17 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-10-17 |
Time |
14:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-08-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-17 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-17 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2022-08-17 13:23:19 | 1ST REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 22080226 | | | 8/17/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET 1: THE POOL SHALL BE DESIGNED AND CONSTRUCTED | | | IN ACCORDANCE WITH THE CURRENT ANSI/APSP STANDARDS- | | | SEC. R4501.6.1 FBC RES. PLACE NOTES ON THE PLAN | | | VERIFYING COMPLIANCE. | | | | | | 2) SHEET 1: THE PROJECT SPECS INDICATE THE POOL AND SPA | | | AT 17,600 GALLONS- THE THD CALCULATIONS INDICATE 15400 | | | GALLONS FOR POOL. IT APPEARS THE SPA IS NOT INCLUDED IN | | | THE CALCULATIONS. PLEASE CORRECT- SEC. 4.4.9 & 4.4.9.1 | | | ANSI/APSP/ICC-7. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-10-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-10-17 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-10-17 |
Time |
14:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-09-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-09-16 |
Time |
07:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-09-16 |
Time |
07:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-08-15 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-08-15 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-08-15 |
Time |
11:42 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy