Plan Review Details - Permit 22080232
Plan Review Stops For Permit 22080232
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-09-01 Cont ID  
Sent By cpuell Date 2022-09-01 Time 16:13 Rev Time 0.00
Received By cpuell Date 2022-09-01 Time 16:13 Sent To  
Notes
2022-09-01 16:14:30UPDATED PERMIT TO REFLECT THE CORRECT ADDRESS

Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status P Date 2022-09-21 Cont ID  
Sent By swelter Date 2022-09-21 Time 17:13 Rev Time 0.00
Received By swelter Date 2022-09-21 Time 17:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-11-07 Cont ID  
Sent By rmcphers Date 2022-11-07 Time 10:28 Rev Time 0.00
Received By rmcphers Date 2022-11-07 Time 10:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-10-31 Cont ID  
Sent By rmcphers Date 2022-10-31 Time 09:43 Rev Time 0.00
Received By rmcphers Date 2022-10-31 Time 09:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-09-22 Cont ID  
Sent By rmcphers Date 2022-09-22 Time 14:34 Rev Time 0.00
Received By rmcphers Date 2022-09-22 Time 09:50 Sent To  
Notes
2022-09-22 14:34:28NEW CONCESSION AND RESTROOM BUILDINGS
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE WALL FINISHES SURROUNDING THE
 MOP/SERVICE SINK TO COMPLY WITH FBC 1210.2.2 WALLS AND
 PARTITIONS.
 WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE
 SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH,
 HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS
 THAN 4 FEET (1219 MM) ABOVE THE FLOOR - (DRYWALL IS NOT
 CONSIDERED A HARD SURFACE)
  
 2) PLEASE SHOW THE ATTIC ACCESS LOCATION AND SIZE PER
 FBC 1209.2
  
 3) PLEASE SHOW THE ATTIC VENTILATION PER FBC 1203.2
  
 4) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS, EXTERIOR
 DOORS, ROOFING SYSTEMS - ALL PRODUCT APPROVALS NEED TO
 BE REVIEWED AND MARKED APPROVED BY THE BUILDING
 DESIGNER OF RECORD - FBC WPB 107.3.4
  
 5) PLEASE PROVIDE SIGNED AND SEALED DETAILS FROM AN
 ARCHITECT OR ENGINEER FOR THE IRON SECURITY GATES
 ATTACHED TO THE RESTROOM BUILDING - WHICH ARE SUBJECT
 TO WIND LOADS PER FBC 1609 - OR PROVIDE PRODUCT
 APPROVALS AS NOTED IN COMMENT 4.
  
 6) PLEASE SHOW THE BUILDING CONSTRUCTION TYPE PER FBC
 CHAPTER 6
  
 7) PLEASE PROVIDE SIGNED AND SEALED DETAILS FROM AN
 ARCHITECT OR ENGINEER FOR THE ALUMINUM CANOPIES - WHICH
 ARE SUBJECT TO WIND LOADS PER FBC 1609 - OR PROVIDE
 PRODUCT APPROVALS AS NOTED IN COMMENT 4.
  
 8) PLEASE SHOW ON THE DRAWINGS THE WALL AND CEILING
 INSULATION IF ANY PER THE ENERGY CALCULATIONS.
  
 9) PLEASE PROVIDE A COPY OF THE SOILS REPORT
 (GEOTECHNICAL REPORT) AS NOTED ON DRAWING S-3.
  
 10) ACCESSIBLE RESTROOM = PLEASE SHOW THE DOOR
 MANEUVERING CLEARANCE FOR THE SECURITY GATE TO EXIT THE
 RESTROOM - FBC A 404.2.4
  
 11) ACCESSIBLE RESTROOM = PLEASE SHOW THE TOILET SEAT
 COVER DISPENSER ABOVE THE GRAB BAR TO COMPLY WITH THE
 REQUIRED CLEARANCE FBC A 609.3 THE SPACE BETWEEN THE
 GRAB BAR AND PROJECTING OBJECTS ABOVE SHALL BE 12
 INCHES (305 MM) MINIMUM.
  
 12) REST ROOMS = PLEASE SHOW THE STALL DIMENSIONS AND
 THE GRAB BAR DIMENSIONS FOR THE REQUIRED AMBULATORY
 ACCESSIBLE COMPARTMENT - PER FBC A 604.8.2 -- FBC A
 213.3.1TOILET COMPARTMENTS.
 WHERE TOILET COMPARTMENTS ARE PROVIDED, AT LEAST ONE
 TOILET COMPARTMENT SHALL COMPLY WITH 604.8.1. IN
 ADDITION TO THE COMPARTMENT REQUIRED TO COMPLY WITH
 604.8.1, AT LEAST ONE COMPARTMENT SHALL COMPLY WITH
 604.8.2 WHERE SIX OR MORE TOILET COMPARTMENTS ARE
 PROVIDED, OR WHERE THE COMBINATION OF URINALS AND WATER
 CLOSETS TOTALS SIX OR MORE FIXTURES.
  
 13) A SEPARATE PERMIT IS REQUIRED FOR THE EXISTING
 BUILDING DEMOLITION.
  
 14) ITEMS SUCH AS ALUMINUM CANOPY DETAILS, ROOFING
 SYSTEMS, WINDOW AND DOOR PRODUCT APPROVALS MAY BE
 DEFERRED SUBMITTALS BY LISTING ITEMS TO BE DEFERRED ON
 THE CONSTRUCTION DOCUMENTS - 107.3.4.1 DEFERRED
 SUBMITTALS. FOR THE PURPOSES OF THIS SECTION, DEFERRED
 SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF THE DESIGN
 THAT ARE NOT SUBMITTED AT THE TIME OF THE APPLICATION
 AND THAT ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL
 WITHIN A SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL
 ITEMS SHALL HAVE THE PRIOR APPROVAL OF THE BUILDING
 OFFICIAL. THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE SHALL LIST THE DEFERRED SUBMITTALS
 ON THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE
 BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED SUBMITTAL
 ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN
 PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW
 THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A
 NOTATION INDICATING THAT THE DEFERRED SUBMITTAL
 DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL
 CONFORMANCE TO THE DESIGN OF THE BUILDING. THE DEFERRED
 SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE
 DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE
 BUILDING OFFICIAL.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-09-26 Cont ID  
Sent By ppetty Date 2022-09-26 Time 07:22 Rev Time 0.00
Received By ppetty Date 2022-09-26 Time 07:22 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2022-11-14 Cont ID  
Sent By rrossano Date 2022-11-14 Time   Rev Time 0.00
Received By rrossano Date 2022-11-14 Time   Sent To  
Notes
2022-11-14 12:48:46UPLOAD APPROVED ENGINEERING PLANS, ONCE RELEASED.

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2022-10-19 Cont ID  
Sent By rrossano Date 2022-10-19 Time   Rev Time 0.00
Received By rrossano Date 2022-10-19 Time   Sent To  
Notes
2022-10-19 12:50:40UNDER FORMAL ENGINEERING REVIEW E22090027.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2022-09-19 Cont ID  
Sent By rrossano Date 2022-09-19 Time   Rev Time  
Received By rrossano Date 2022-09-19 Time   Sent To  
Notes
2022-09-19 11:25:16PENDING A FORMAL ENGINEERING SUBMITTAL.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-09-08 Cont ID  
Sent By   Date 2022-09-08 Time   Rev Time 0.00
Received By bdolan Date 2022-09-08 Time 11:48 Sent To  
Notes
2022-09-08 11:49:06FIRE DEPARTMENT HAS NO OBJECTION TO THE PROJECT.
  
 PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
  
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-11-15 Cont ID  
Sent By lmarchan Date 2022-11-15 Time 07:48 Rev Time 0.00
Received By lmarchan Date 2022-11-06 Time 06:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-11-03 Cont ID  
Sent By medwards Date 2022-11-03 Time 14:43 Rev Time 0.00
Received By medwards Date 2022-10-13 Time 07:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-10-11 Cont ID  
Sent By lmarchan Date 2022-10-11 Time 11:40 Rev Time 0.00
Received By lmarchan Date 2022-09-01 Time 15:04 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2022-11-15 Cont ID  
Sent By dbattles Date 2022-11-15 Time 13:08 Rev Time 0.00
Received By dbattles Date 2022-11-15 Time 13:07 Sent To  
Notes
2022-11-15 13:08:53ADDED IMPACT OFFICE LETTER OF EXEMPTION TO FRONT SCREEN
 AND FILENET.
2022-11-07 16:09:2811/7/22 EMAILED IMPACT FOR REVIEW-AO
2022-11-06 06:40:45CORRECTION - 22080232 NOT SENT TO PBC IMPACT OFFICE
 YET. NEW ARCHITECTURAL DRAWINGS UPLOADED 11/03/2022. B
 STOP ADDED AO
2022-11-06 06:31:0111/06/2022 EMAILED IMPACT FOR REVIEW-AO

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-09-22 Cont ID  
Sent By rmcphers Date 2022-09-22 Time 14:34 Rev Time 0.00
Received By rmcphers Date 2022-09-22 Time 14:34 Sent To  
Notes
2022-09-22 14:35:12PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-11-03 Cont ID  
Sent By medwards Date 2022-11-03 Time 14:41 Rev Time 0.00
Received By medwards Date 2022-11-03 Time 14:40 Sent To  
Notes
2022-11-03 14:41:30TOILET BUILDING APPROVED 9/20/2022

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-09-20 Cont ID  
Sent By medwards Date 2022-09-20 Time 07:14 Rev Time 0.00
Received By medwards Date 2022-09-20 Time 07:14 Sent To  
Notes
2022-09-20 07:14:261ST REVIEW FMC
 PERMIT: 22080232
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE THE ENERGY CALCULATIONS. FEC C402
  
 2) PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FEC C403.2.1
  
 3) PROVIDE A DETAIL OF THE CONDENSATE DRAIN TERMINATION
 LOCATION. FMC 307.2.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-10-19 Cont ID  
Sent By rwbrown Date 2022-10-19 Time 15:03 Rev Time 0.00
Received By rwbrown Date 2022-10-19 Time 15:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-09-21 Cont ID  
Sent By rwbrown Date 2022-09-21 Time 13:33 Rev Time 0.00
Received By rwbrown Date 2022-09-21 Time 13:33 Sent To  
Notes
2022-09-21 13:38:011ST PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
  
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. PAGE P101 - 2020 FPC 1002.1 FIXTURE TRAPS - THE
 FLOOR DRAINS ARE REQUIRED TO HAVE P-TRAPS.
  
 2. 2020 FPC 1002.4.1 TRAP SEAL PROTECTION - TRAPS
 SUBJECT TO EVAPORATION ARE REQUIRED TO HAVE PROTECTION.
  
 3. 2020 FPC 607.1 THE WATER HEATER DETAIL SHOWS PIPE
 SIZES OF 3/8", AND THE RISER SHOWS 1/2". PLEASE
 ADDRESS.
  
 4. 2020 FPC 607.1.1 - SHOW HOT WATER PROTECTION. THE
 THERMOSTAT FOR THE WATER HEATER CANNOT BE THE LIMITING
 DEVICE FOR HOT WATER DELIVERY.
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status N Date 2022-10-31 Cont ID  
Sent By rmcphers Date 2022-10-31 Time 09:43 Rev Time 0.00
Received By rmcphers Date 2022-10-31 Time 09:43 Sent To  
Notes
2022-10-31 09:44:06ROOFING SYSTEM TO BE DEFERRED

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-09-22 Cont ID  
Sent By rmcphers Date 2022-09-22 Time 14:35 Rev Time 0.00
Received By rmcphers Date 2022-09-22 Time 14:35 Sent To  
Notes
2022-09-22 14:36:02SEE BUILDING PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-11-07 Cont ID  
Sent By rmcphers Date 2022-11-07 Time 10:28 Rev Time 0.00
Received By rmcphers Date 2022-11-07 Time 10:28 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-10-31 Cont ID  
Sent By rmcphers Date 2022-10-31 Time 09:44 Rev Time 0.00
Received By rmcphers Date 2022-10-31 Time 09:44 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-09-22 Cont ID  
Sent By rmcphers Date 2022-09-22 Time 14:45 Rev Time 0.00
Received By rmcphers Date 2022-09-22 Time 14:45 Sent To  
Notes
2022-09-20 07:16:53MECHANICAL DIGITAL SIGNATURES APPROVED ME

Review Stop Z ZONING
Rev No 2 Status P Date 2022-11-03 Cont ID  
Sent By dbattles Date 2022-11-03 Time 11:29 Rev Time 0.00
Received By dbattles Date 2022-11-03 Time 11:29 Sent To  
Notes
2022-11-15 17:03:09JR HAS RESTAMPED THE PLANS.

Review Stop Z ZONING
Rev No 1 Status P Date 2022-10-11 Cont ID  
Sent By jroach Date 2022-10-11 Time 09:56 Rev Time 0.00
Received By jroach Date 2022-10-11 Time 09:56 Sent To  
Notes
2022-10-11 09:56:50THIS PERMIT REVIEW IS LIMITED TO THE CONCESSION
 BUILDING ONLY!
  
 THIS REVIEW IS SUBJECT TO THE FOLLOWING PROVISOS:
  
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED TO, REVIEWED, AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT ??? PLANNING DIVISION.
  
 2. ALL SIGNAGE WILL BE SUBJECT TO THE REQUIREMENTS OF
 ARTICLE XIII OF THE CITY???S ZONING AND LAND
 DEVELOPMENT REGULATIONS.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ??? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  