Plan Review Details - Permit 22080211
Plan Review Stops For Permit 22080211
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2022-11-15 Cont ID  
Sent By rmcdouga Date 2022-11-15 Time 13:47 Rev Time 0.00
Received By rmcdouga Date 2022-11-15 Time 13:47 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-09-16 Cont ID  
Sent By rmcdouga Date 2022-09-16 Time 08:26 Rev Time 0.00
Received By rmcdouga Date 2022-09-16 Time 08:25 Sent To  
Notes
2022-09-16 08:28:23PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE ADDRESS, PERMIT NUMBER AND ???ASBESTOS???
 IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-11-15 Cont ID  
Sent By rmcdouga Date 2022-11-15 Time 14:34 Rev Time 0.00
Received By rmcdouga Date 2022-11-15 Time 14:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-09-16 Cont ID  
Sent By rmcdouga Date 2022-09-16 Time 11:34 Rev Time 0.00
Received By rmcdouga Date 2022-09-16 Time 08:37 Sent To  
Notes
2022-09-16 11:34:21PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) ON SHEET A1.2 LIFE SAFETY PLAN THE COMMON PATH OF
 TRAVEL IS SPECIFIED AS 166 FT. FBC 1006.2.1 REQUIRES
 TWO EXITS WHEN THE COMMON PATH OF TRAVEL IS MORE THAN
 100 FT.
  
 2) THE OCCUPANT LOAD CALCULATIONS ON THE PLANS HAS
 FRACTIONS WHICH ARE REQUIRED TO BE ROUNDED UP BECAUSE
 YOU CAN NOT HAVE A FRACTION OF PEOPLE. IF YOU ROUND UP
 THE NUMBERS IN THE CHART YOU WILL HAVE A TOTAL OCCUPANT
 LOAD OF 52 (3+29+1+1+18=52). FBC 1006.2.1 REQUIRES TWO
 EXISTS FROM THE SPACE IF THE OCCUPANT LOAD EXCEEDS 49
 PEOPLE.
  
 3) SHOW COMPLIANCE WITH FBC 1007.1.1 EXCEPTION (2)
 REQUIRES THE TWO EXITS TO BE SEPARATED BY NOT LESS THAN
 ONE-THIRD THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL
 DIMENSION OF THE AREA SERVED.
  
 4) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH
 OF THE REVIEW COMMENTS HAS BEEN ADDRESSED
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-08-16 Cont ID  
Sent By fgiaquin Date 2022-08-16 Time 23:01 Rev Time 0.00
Received By fgiaquin Date 2022-08-16 Time 22:31 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-10-03 Cont ID  
Sent By cwalker Date 2022-10-03 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
2022-10-03 10:02:02FIRE PROVISO COMMENTS:
  
 ALL EXISTING LIFE SAFETY SYSTEMS (FIRE SPRINKLER AND/OR
 FIRE ALARM) ARE TO REMAIN OPERATIONAL DURING ALL PHASES
 OF DEMOLITION AND CONSTRUCTION.
  
 ANY IMPAIRMENT TO ANY LIFE SYSTEM (FIRE SPRINKLER
 AND/OR FIRE ALARM) THAT EXCEEDS 4 CONTINUOUS HOURS IN
 DURATION WILL REQUIRE THE IMPLEMENTATION OF A FIRE
 WATCH.
  
 ANY WORK ON ANY LIFE SAFETY SYSTEM (FIRE SPRINKLER
 AND/OR FIRE ALARM) MUST BE CONDUCTED UNDER SEPARATE
 PERMITS BY PROPERLY QUALIFIED CONTRACTORS.
  
 C. WALKER
  
 561-804-4762
  
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-08-09 Cont ID  
Sent By cwalker Date 2022-08-09 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
2022-08-09 10:17:48FIRE PROVISO COMMENTS:
 ALL EXISTING LIFE SAFETY SYSTEMS (FIRE SPRINKLER AND
 FIRE ALARM) ARE TO REMAIN OPERATIONAL DURING ALL PHASES
 OF DEMOLITION AND CONSTRUCTION. ANY IMPAIRMENT TO ANY
 LIFE SAFETY SYSTEM (FIRE SPRINKLER AND/OR FIRE ALARM)
 THAT EXCEEDS 4 CONTINUOUS HOURS IN DURATION WILL
 REQUIRE THE IMPLEMENTATION OF A FIRE WATCH.
 C. WALKER
 561-804-4762
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-11-15 Cont ID  
Sent By rmcdouga Date 2022-11-15 Time 14:34 Rev Time 0.00
Received By rmcdouga Date 2022-10-02 Time 08:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-09-16 Cont ID  
Sent By rmcdouga Date 2022-09-16 Time 11:34 Rev Time 0.00
Received By rmcdouga Date 2022-08-08 Time 06:57 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2022-09-16 Cont ID  
Sent By rmcdouga Date 2022-09-16 Time 08:37 Rev Time 0.00
Received By rmcdouga Date 2022-09-16 Time 08:37 Sent To  
Notes
2022-09-16 08:38:04NO CHANGE OF OCCUPANCY OR ADDITION OF SPACE.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-08-17 Cont ID  
Sent By medwards Date 2022-08-17 Time 06:08 Rev Time 0.00
Received By medwards Date 2022-08-17 Time 06:08 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2022-10-06 Cont ID  
Sent By rwbrown Date 2022-10-06 Time 09:10 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-08-15 Cont ID  
Sent By ccole Date 2022-08-15 Time 15:49 Rev Time 0.00
Received By ccole Date 2022-08-15 Time 15:31 Sent To  
Notes
2022-08-15 15:50:281ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22080211
 8/15/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A1.2 SHOWS A NEW COFFEE BAR WITH SINK AND
 DISHWASHER. PLEASE SUBMIT A PLUMBING PIPING PLAN AND
 RISER DRAWINGS- SEC. 107.3.5.1.3 WPB.
  
 2) PROVIDE AN ELEVATION DRAWING OF THE KITCHEN SHOWING
 COMPLIANCE WITH SINK HEIGHT AND REACH RANGES FOR
 APPLIANCES- SECS. 606.3 & 308 FBC ACC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-11-08 Cont ID  
Sent By rwbrown Date 2022-11-08 Time 11:15 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-08-15 Cont ID  
Sent By ccole Date 2022-08-15 Time 15:58 Rev Time 0.00
Received By ccole Date 2022-08-15 Time 15:58 Sent To  
Notes
***NONE***