| Plan Review Stops For Permit 22080183 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2022-09-26 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-09-26 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-09-26 |
Time |
13:13 |
Sent To |
|
|
| Notes |
| 2022-09-26 13:15:51 | 4065 N HAVERHILL RD # B7 IS THE CORRECT ADDRESS FOR THE | | | INTERIOR REMODEL, UPDATED PERMIT |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2022-08-30 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-08-30 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-08-30 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2022-08-30 16:58:30 | INCORRECT ADDRESS THE SOUTH SECTION ON THE WEST | | | BUILDING HAS THE ADDRESS OF 4065 N HAVERHILL RD (4075 N | | | HAVERHILL RD IS EXCLUSIVELY FOR PUBLIX. THE PLANS | | | INDICATE THAT YOU WILL BE MERGING SUITES B6 AND B8, ONE | | | OF THESE SUITES WILL NEED TO BE RETIRE SO THAT ONLY ONE | | | SUITE ADDRESS REMAINS, PLEASE HAVE THE OWNER CONTACT ME | | | SO THAT ONE OF THE ADDRESSES CAN BE RETIRED. | | | [email protected] OR CALL 561-805-6659 |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
P |
Date |
2023-01-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-01-17 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2022-10-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-10-31 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-10-31 |
Time |
07:33 |
Sent To |
|
|
| Notes |
| 2022-10-31 07:45:41 | COMMERCIAL ASBESTOS | | | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON THE CONTRACTORS LETTERHEAD, STATING THAT | | | THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | | ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION | | | -RENOVATION.HTML | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2022-09-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-09-28 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-09-28 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2022-09-28 13:19:40 | COMMERCIAL ASBESTOS | | | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON THE CONTRACTORS LETTERHEAD, STATING THAT | | | THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | | ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION | | | -RENOVATION.HTML | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-01-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-01-17 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-01-17 |
Time |
07:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-10-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-10-31 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-09-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-09-28 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-09-28 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2022-09-28 13:54:00 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 22080183 | | | ADD: 4065 N HAVERHILL RD # B7 | | | CONT: NORTHSTAR GENERAL CONTRACTING | | | TEL: 561-239-9873 | | | E-MAIL: KEN@[email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. SEPT. 28TH/2022 | | | ACTION: DENIED | | | | | | 1) SHEET A-1 THE ROOM FINISH SCHEDULE INDICATES FOR THE | | | 2 ACCESSIBLE RESTROOMS THE WALLS ARE TO BE EPOXY PAINT. | | | 2020 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS COMMENT | | | IS A RESULT OF THE BUILDING OFFICIAL INTERPRETATION ON | | | 06/2020. IN BATHROOMS, RESTROOMS & SERVICE SINKS AREAS | | | EPOXY PAINT IS NO LONGER CONSIDERED A SMOOTH HARD, | | | NON-ABSORBENT SURFACE. | | | 1210.2.2 WALLS & PARTITIONS WITHIN 2 FEET OF SERVICE | | | SINKS, URINALS, AND WATER CLOSETS SHALL HAVE A SMOOTH, | | | HARD, NON-ABSORBENT SURFACE TO A HEIGHT OF NOT LESS | | | THAN 4 FEET ABOVE THE FLOOR, EXCEPT FOR STRUCTURAL | | | ELEMENTS, THE MATERIAL USED IN SUCH WALLS SHALL BE OF A | | | TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. | | | | | | 2) SHEET M-1 INDICATES THE ROOF DECK IS GOING TO BE | | | PENETRATED WITH 4 20-INCH DIA. GAS FLUES UP THROUGH THE | | | ROOF. THERE ARE NO DETAILS ON SHEET M-2 ROOF MECHANICAL | | | SHEET FOR THE NEW ROOF FRAMING AROUND EACH PENETRATION, | | | NOR IS THERE A HEIGHT GIVEN FOR THE GAS FLUE, NOR GAUGE | | | OF DUCT NOR TYPE OF WEATHER SHIELD/CAP. THE SAME IS | | | TRUE FOR THE FRESH AIR INTAKE DETAIL. THERE IS A NOTE: | | | ATTACHMENT BY STRUCTURAL ENGINEER AND OR ARCHITECT. | | | | | | 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION 107.2.1. DRAWINGS & | | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | | TECHNICAL CODES. CONSTRUCTION DOCUMENTS SHALL BE | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | 2020 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL | | | MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY | | | METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT | | | EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY | | | AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES. | | | EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE | | | OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES | | | SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND | | | LOADS. | | | | | | 3) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ SEMI-RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2023-02-21 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-02-21 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-02-21 |
Time |
14:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2023-01-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-01-20 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-01-20 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2023-01-20 13:30:10 | PLAN IS NOT DIGITALLY SIGNED JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2022-11-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-11-13 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-11-13 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2022-11-13 17:09:03 | PLAN IS NOT DIGITALLY SIGNED JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-09-22 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-09-22 |
Time |
01:33 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-09-22 |
Time |
01:20 |
Sent To |
|
|
| Notes |
| 2022-09-22 01:55:00 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) CIRCUITS 13,15,17,19,21,23 TO BE GFCI PROTECTED PER | | | 422.5 , 210.8(B) | | | | | | APPLIANCES IDENTIFIED IN 422.5(A)(1) THROUGH (5) RATED | | | 250 VOLTS OR LESS AND 60 AMPERES OR LESS, SINGLE- OR | | | 3-???PHASE, SHALL BE PROVIDED WITH GFCI PROTECTION FOR | | | PERSONNEL. MULTIPLE GFCI PROTECTIVE DEVICES SHALL BE | | | PERMITTED BUT SHALL NOT BE REQUIRED. | | | (1) AUTOMOTIVE VACUUM MACHINES PROVIDED FOR PUBLIC USE | | | | | | (2) DRINKING WATER COOLERS | | | | | | (3) HIGH-PRESSURE SPRAY WASHING MACHINES ??? | | | CORD-AND-PLUG-CONNECTED | | | | | | (4) TIRE INFLATION MACHINES PROVIDED FOR PUBLIC USE | | | | | | (5) VENDING MACHINE |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-10-28 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-10-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-10-28 11:20:30 | FIRE PROVISO COMMENTS: | | | | | | (1) ALL EXISTING LIFE SAFETY SYSTEMS (FIRE SPRINKLER | | | AND/OR FIRE ALARM) SHALL REMAIN OPERATIONAL DURING ALL | | | PHASES OF DEMOLITION AND CONSTRUCTION. | | | | | | (2) ANY MODIFICATIONS, ALTERATIONS, ADDITIONS, ETC. TO | | | ANY LIFE SAFETY SYSTEM (FIRE SPRINKLER AND/OR FIRE | | | ALARM) SHALL BE CONDUCTED BY PROPERLY LICENSED | | | CONTRACTORS AND PERFORMED UNDER SEPARATE PERMITS AND | | | SHOP DRAWINGS. | | | | | | (3) ANY IMPAIRMENT TO ANY LIFE SAFETY SYSTEM (FIRE | | | SPRINKLER AND/OR FIRE ALARM) THAT EXCEEDS 4 CONTINUOUS | | | HOURS IN DURATION SHALL REQUIRE THE IMPLEMENTATION OF A | | | FIRE WATCH. | | | | | | (4) ALL EXISTING LIFE SAFETY SYSTEMS (FIRE SPRINKLER | | | AND/OR FIRE ALARM) SHALL BE PROTECTED FROM DAMAGE | | | INCLUDING PAINTING. | | | | | | C. WALKER | | | | | | 561-804-4762 | | | | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-08-26 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-08-26 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-08-26 11:46:43 | FIRE PROVISO COMMENTS: | | | | | | (1) ALL EXISTING LIFE SAFETY SYSTEMS (FIRE SPRINKLER | | | AND/OR FIRE ALARM) SHALL REMAIN OPERATIONAL DURING ALL | | | PHASES OF DEMOLITION AND CONSTRUCTION. | | | | | | (2) ANY MODIFICATIONS, ALTERATIONS, ADDITIONS, ETC. TO | | | ANY LIFE SAFETY SYSTEM (FIRE SPRINKLER AND/OR FIRE | | | ALARM) SHALL BE CONDUCTED BY PROPERLY LICENSED | | | CONTRACTORS AND PERFORMED UNDER SEPARATE PERMITS AND | | | SHOP DRAWINGS. | | | | | | (3) ANY IMPAIRMENT TO ANY LIFE SAFETY SYSTEM (FIRE | | | SPRINKLER AND/OR FIRE ALARM) THAT EXCEEDS 4 CONTINUOUS | | | HOURS IN DURATION SHALL REQUIRE THE IMPLEMENTATION OF A | | | FIRE WATCH. | | | | | | (4) ALL EXISTING LIFE SAFETY SYSTEMS (FIRE SPRINKLER | | | AND/OR FIRE ALARM) SHALL BE PROTECTED FROM DAMAGE | | | INCLUDING PAINTING. | | | | | | C. WALKER | | | | | | 561-804-4762 | | | | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2023-02-09 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-02-09 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-02-09 |
Time |
11:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2023-01-17 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2023-01-17 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2023-01-17 13:43:25 | APPROVED |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2022-10-31 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2022-10-31 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2022-10-31 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2022-10-31 15:47:16 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | | EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 22080183 4075 N HAVERHILL RD | | | | | | GAS COMMENTS: DENIED | | | | | | 1. COMPLIED | | | | | | 2. COMPLIED | | | | | | 3. SECOND REQUEST: P-3/GAS RISER: REGULATOR AT METER | | | REDUCES PRESSURE TO 7 INCHES WATER COLUMN; SIZING | | | CALCULATIONS ARE BASED ON FBC FG TABLE 402.4(5) 2 | | | PSI/1PD/6SG. PER WPB FBC 107.2.1, PLEASE CLARIFY AND | | | RECONCILE. | | | NEW COMMENT: NOTE FOR REGULATOR AT METER REDUCES | | | PRESSURE TO 7 INCHES WATER COLUMN HAS BEEN ELIMINATED; | | | SIZING CALCULATIONS ARE STILL BASED ON FBC FG TABLE | | | 402.4(5) 2 PSI/1PD/6SG INDICATING A 2 PSI SYSTEM. | | | ***CONFIRM ON THE PLAN 2 PSI SYSTEM OR LESS THAN 2PSI | | | SYSTEM | | | ***IF LESS THAN 2 PSI SYSTEM, PROVIDE A SIZING TABLE | | | SELECTED FROM FBC FG 402.4 | | | ***IF A 2PSI SYSTEM IS REQUIRED FOR DISTRIBUTION, THEN | | | SPECIFY AND PROVIDE MP REGULATORS FOR FINAL | | | CONNECTIONS. PROVIDE SIZING TABLE (FROM FBC FG 402.4) | | | FOR REDUCED PRESSURE PIPING AND MAXIMUM DEVELOPED | | | LENGTH OF REDUCED PRESSURE SYSTEM(S) FROM MP REGULATOR | | | TO FINAL CONNECTIONS. SHOW LOCATIONS OF MP REGULATORS. | | | | | | 4. COMPLIED | | | | | | 5. COMPLIED | | | | | | 6. COMPLIED | | | | | | 7. COMPLIED | | | | | | 8. SECOND REQUEST:P-1/TANKLESS GAS WATER HEATER DETAIL | | | INDICATES A CONCENTRIC VENT WITH SINGLE POINT | | | CONNECTION FOR SINGLE HEATER. SCHEDULED NAVIEN NPE-240A | | | AND P-1/HIGH TEMP DOMESTIC WATER HEATER DETAIL REQUIRES | | | DEDICATED COMBUSTION AIR INLET AND EXHAUST OUTLET. | | | REFER TO NAVIEN COMMON VENT SYSTEM INSTALLATION MANUAL. | | | UPDATED DETAIL SHOWS A CONCENTRIC VENT MANIFOLD WITH | | | SINGLE POINT CONNECTION FOR EACH OF THE THREE WATER | | | HEATERS. | | | NAVIEN COMMON VENT SYSTEM INSTALLATION MANUAL FOR | | | SCHEDULED WATER HEATERS REQUIRES A DEDICATED INTAKE | | | MANIFOLD AND A DEDICATED EXHAUST MANIFOLD. PER FBC FG | | | 503.4, PROVIDE VENT SYSTEM IN ACCORDANCE WITH | | | MANUFACTURER DIRECTIONS. | | | | | | PER WPB FBC 107.2.1, 107.3.5.1.5, PROVIDE THE | | | FOLLOWING: | | | ***A) A DETAIL THAT PROPERLY ADDRESSES THE VENTING OF | | | THE THREE UNITS. | | | ***B) SIZE(S) AND MATERIAL SPECIFICATION FOR VENTS. | | | | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER PX928 | | | PLUMBING INSPECTOR BN2148 | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-246-0882 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-09-07 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2022-09-07 |
Time |
17:17 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2022-09-06 |
Time |
17:16 |
Sent To |
|
|
| Notes |
| 2022-09-07 17:15:46 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | | EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 22080183 4075 N HAVERHILL RD | | | | | | GAS COMMENTS: DENIED | | | | | | 1. PER WPB FBC 107.2.1, 107.3.5.1.5, PROVIDE | | | MANUFACTURER'S SPECIFICATION/INSTALLATION MANUAL FOR | | | THE FOLLOWING SHALL BE PROVIDED FOR THE FOLLOWING: | | | ***WATER HEATERS | | | ***DRYERS (EACH MODEL UNIT) | | | ***INLET/EXHAUST VENTS FOR WATER HEATERS | | | ***REGULATORS | | | ALL SUBMITTALS SHALL BE APPROVED AND STAMPED BY THE | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE PER WPB FBC | | | 107.2.1, 107.3.4. SUBMITTALS MAY BE DEFERRED IN | | | ACCORDANCE WITH SECTION WPB FBC 107.3.4.1. DEFERRED | | | SUBMITTALS SHALL BE LISTED ON THE PLANS. THE | | | INSTALLATION MANUALS FOR ALL GAS APPLIANCES / EQUIPMENT | | | SHALL BE ONSITE AT THE TIME OF INSPECTION PER FBC FG | | | 305.1. | | | | | | 2. PER WPB FBC 107.2.1, 107.3.5.1.5, PROVIDE ON THE GAS | | | RISER DIAGRAM, ALL PIPE SIZES. | | | | | | 3. P-3/GAS RISER: REGULATOR AT METER REDUCES PRESSURE | | | TO 7 INCHES WATER COLUMN; SIZING CALCULATIONS ARE BASED | | | ON FBC FG TABLE 402.4(5) 2 PSI/1PD/6SG. PER WPB FBC | | | 107.2.1, PLEASE CLARIFY AND RECONCILE. | | | IF A 2PSI SYSTEM IS REQUIRED FOR DISTRIBUTION, THEN | | | SPECIFY AND PROVIDE MP REGULATORS AT APPLIANCES. | | | PROVIDE SIZING TABLE (FROM FBC FG 402.4) FOR REDUCED | | | PRESSURE PIPING AND MAXIMUM DEVELOPED LENGTH OF REDUCED | | | PRESSURE SYSTEM(S). PROVIDE DETAIL FOR MP REGULATOR | | | CONNECTION TO APPLIANCE. COMPLY WITH FBC FG 409.4 AND | | | 410.2. | | | | | | 4. PER WPB FBC 107.2.1, 107.2.1.2 AND 107.3.5.1.5, | | | PROVIDE ON THE GAS RISER DIAGRAM, ITEM NUMBER AT EACH | | | DRYER POC TO MATCH GAS SCHEDULE. | | | | | | 5. P-3/GAS SCHEDULE: PER WPB FBC 107.2.1, 107.3.5.1.5, | | | PROVIDE BTU RATING PER UNIT FOR EACH DRYER MODEL AND | | | FOR THE WATER HEATER. | | | | | | 6. P-3/GAS SCHEDULE INDICATES QUANTITY OF ONE (1) EACH | | | WATER HEATER; P-1/HIGH TEMP DOMESTIC WATER HEATER | | | DETAIL, P-2 PLAN AND P-3 RISER DIAGRAM INDICATE THREE | | | (3) EACH. PER WPB FBC 107.2.1, PLEASE CLARIFY AND | | | RECONCILE. | | | | | | 7. PER WPB FBC 107.2.1, 107.3.5.1.5, PROVIDE COMBUSTION | | | AIR CALCULATIONS FOR THE DRYERS PER FBC FG 304.1. | | | | | | 8. P-1/TANKLESS GAS WATER HEATER DETAIL INDICATES A | | | CONCENTRIC VENT WITH SINGLE POINT CONNECTION FOR SINGLE | | | HEATER. SCHEDULED NAVIEN NPE-240A AND P-1/HIGH TEMP | | | DOMESTIC WATER HEATER DETAIL REQUIRES DEDICATED | | | COMBUSTION AIR INLET AND EXHAUST OUTLET. REFER TO | | | NAVIEN COMMON VENT SYSTEM INSTALLATION MANUAL. | | | PER WPB FBC 107.2.1, 107.3.5.1.5, PROVIDE THE | | | FOLLOWING: | | | ***A) A DETAIL THAT PROPERLY ADDRESSES THE VENTING OF | | | THE THREE UNITS. | | | ***B) SIZE(S) AND MATERIAL SPECIFICATION FOR VENTS. | | | | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER PX928 | | | PLUMBING INSPECTOR BN2148 | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-246-0882 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-03-06 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-03-06 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-03-02 |
Time |
08:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-02-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-02-24 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-02-08 |
Time |
10:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-01-23 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-01-23 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-01-12 |
Time |
09:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-11-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-11-13 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-10-27 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-09-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
cdecoeur |
Date |
2022-08-26 |
Time |
05:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2022-09-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-09-28 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-09-28 |
Time |
13:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2023-03-06 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-03-06 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-03-06 |
Time |
13:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2023-02-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-14 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-14 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2023-02-14 11:51:23 | 4TH ATTEMPT AT FINDING THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS, SEE PREVIOUS COMMENT BELOW. | | | | | | 1) THIS REVIEWER DOES NOT SEE THE MECHANICAL EQUIPMENT | | | SIZING CALCULATIONS ASKED FOR IN THE PREVIOUS REVIEW | | | CYCLES. PLEASE PROVIDE THEM. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2023-01-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-13 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-13 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2023-01-13 15:10:39 | 3RD REVIEW FMC | | | PERMIT: 22080183 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THIS REVIEWER DOES NOT SEE THE MECHANICAL EQUIPMENT | | | SIZING CALCULATIONS ASKED FOR IN THE PREVIOUS REVIEW | | | CYCLES. PLEASE PROVIDE THEM. | | | | | | 2) PLEASE UNDERSTAND, YOU ARE REQUIRED TO PROVIDE THE | | | OUTDOOR AIR CALCULATIONS BASED ON THE OCCUPANCY | | | CLASSIFICATION FOR EACH USE OF SPACE AND THIS IS | | | CALCULATED BY OCCUPANT DENSITY. ALL FROM TABLE | | | 403.3.1.1. THERE ARE NO HOUSE LIMIT RULES. PROVIDE A | | | CALCULATION FOR EACH USE OF SPACE BASED ON THE MOST | | | SIMILAR OCCUPANCY CLASSIFICATION AND THE OCCUPANT | | | DENSITY IN THE TABLE 403.3.1.1.FMC 403.3.1.1 AND TABLE | | | 403.3.1.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-11-08 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2022-11-08 13:36:26 | 1ST REVIEW FMC | | | PERMIT: 22080183 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE MECHANICAL EQUIPMENT SIZING CALCULATIONS ASKED | | | FOR IN THE 1ST REVIEW CYCLE WAS NOT SUBMITTED THIS | | | CYCLE. PLEASE SUBMIT THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. | | | | | | 2) PROVIDE THE CORRECT OUTDOOR AIR CALCULATIONS FOR A | | | COMMERCIAL LAUNDRY. TABLE 403.3.1.1 CLEARLY PROVIDES | | | THE OCCUPANT LOAD AND THE CFM???S PER PERSON BASED ON | | | THAT OCCUPANT COUNT. THE ENTIRE SPACE IS A COMMERCIAL | | | LAUNDRY. PLEASE USE THE ENTIRE NET SQUARE FOOTAGE FOR | | | THE COMMERCIAL LAUNDRY REQUIRED OUTDOOR AIR | | | CALCULATIONS. FMC 403.3.1.1 AND TABLE 403.3.1.1 | | | | | | 3) PLEASE SHOW THE REQUIRED DUCT DETECTORS IN THE | | | SUPPLY SIDE OF THE MECHANICAL DUCT SYSTEMS. FMC 606.2.2 | | | | | | 1ST REVIEW FMC | | | PERMIT: 22080183 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE MECHANICAL EQUIPMENT SIZING CALCULATIONS ASKED | | | FOR IN THE 1ST REVIEW CYCLE WAS NOT SUBMITTED THIS | | | CYCLE. PLEASE SUBMIT THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. | | | | | | 2) PROVIDE THE CORRECT OUTDOOR AIR CALCULATIONS FOR A | | | COMMERCIAL LAUNDRY. TABLE 403.3.1.1 CLEARLY PROVIDES | | | THE OCCUPANT LOAD AND THE CFM???S PER PERSON BASED ON | | | THAT OCCUPANT COUNT. THE ENTIRE SPACE IS A COMMERCIAL | | | LAUNDRY. PLEASE USE THE ENTIRE NET SQUARE FOOTAGE FOR | | | THE COMMERCIAL LAUNDRY REQUIRED OUTDOOR AIR | | | CALCULATIONS. FMC 403.3.1.1 AND TABLE 403.3.1.1 | | | | | | 3) PLEASE SHOW THE REQUIRED DUCT DETECTORS IN THE | | | SUPPLY SIDE OF THE MECHANICAL DUCT SYSTEMS. FMC 606.2.2 | | | | | | 4) PLEASE SUBMIT A DRYER EXHAUST DUCT DRAWING THAT WILL | | | INCLUDE THE SUBMITTED DRYER SPECS INCLUDING THE MAX. | | | AIR FLOW AND MAKE-UP AIR. THE DRYER MANUALS SUBMITTED | | | DO NOT REFERENCE THE HTT30, HYY45 OR HT075. PLEASE | | | PROVIDE DOCUMENTS WITH THESE MODELS IDENTIFIED. THE M-2 | | | SHEET SPECS OUT A 4INCH DRYER DUCT FOR A SINGLE DRYER | | | WITH A FLEX DUCT FOR THE TRANSITION DUCT. PAGE 35 OF | | | THE DRYER SPECS. SUBMITTED INDICATES A SINGLE EXHAUST | | | DUCT FOR THE DRYERS WOULD BE AN 8 INCH DUCT. PLEASE USE | | | THE SPECS FOR THE DRYERS INCLUDING THE MAX. DISTANCE | | | AND PROVIDE A DRYER EXHAUST DRAWING FOR THIS LAUNDRY. | | | FMC 504.9 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-02 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-02 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2022-09-02 09:56:51 | 1ST REVIEW FMC | | | PERMIT: 22080183 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS | | | FOR THIS NEW LAUNDRY MAT. | | | | | | 2) PROVIDE THE OUTDOOR AIR CALCULATIONS FOR THIS | | | COMMERCIAL LAUNDRY INCLUDING ALL OF THE AREAS IN THIS | | | TENANT SPACE. THE COIN OPERATED LAUNDRY WOULD NEED 711 | | | CFM?S OF OUTDOOR AIR. THE OFFICE AREA WOULD NEED 43 | | | CFM?S OF OUTDOOR AIR FOR A TOTAL OUTDOOR AIR REQUIRED | | | OF 754 CFM?S. FMC 403.3.1.1 AND TABLE 403.3.1.1 | | | | | | 3) PROVIDE THE SPECS FOR THE DRYERS, INCLUDING THE | | | EXHAUST DUCT INSTALLATION AND AN EXHAUST DUCT DRAWING | | | FOR THESE DRYERS FBC 107.3.5 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2023-02-09 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-02-09 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-02-09 |
Time |
11:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2023-01-17 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2023-01-17 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2023-01-17 |
Time |
12:16 |
Sent To |
|
|
| Notes |
| 2023-01-17 14:20:31 | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1 | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 22080183 4065 N HAVERHILL RD #B7 | | | | | | 2ND REVIEW | | | | | | PLUMBING COMMENTS: DENIED | | | | | | PLEASE PROVIDE A RESPONSE CONCERNING A SEPARATE PERMIT | | | FOR THE SOLIDS INTERCEPTOR | | | A SEPARATE PERMIT FOR THE SOLIDS INTERCEPTOR IS | | | REQUIRED TO BE SUBMITTED PRIOR TO ISSUANCE OF THE | | | PRIMARY PERMIT (AS APPLICABLE). YOU CAN SUBMIT AN | | | APPLICATION "TBD" (TO BE DETERMINED) IF YOU DO NOT HAVE | | | A CONTRACTOR SELECTED BY EMAILING A COMPLETED PERMIT | | | APPLICATION TO [email protected] . YOU WILL | | | RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU | | | MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE | | | APPLICATION IS REQUIRED AT THIS TIME. WE RECOMMEND THAT | | | YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME. A | | | SEPARATE PERMIT IS REQUIRED HOWEVER A REVIEW OF THE | | | SYSTEM UNDER THE MAIN PERMIT IS ALSO REQUIRED. | | | AFTER YOU HAVE THE PERMIT(S) GENERATED, PLEASE NOTIFY | | | ME AT [email protected] AND CC SAMANTHA HILL, CHIEF PLANS | | | EXAMINER AT [email protected] AND RYAN BROWN, CHIEF | | | PLUMBING INSPECTOR AT [email protected] VIA EMAIL WITH | | | THE PERMIT NUMBER(S). | | | | | | 1. SECOND REQUEST: THE TMV HAS BEEN REMOVED FROM | | | REVISED P-1/HIGH TEMP DOMESTIC WATER HEATER DETAIL. | | | PROVIDE A TEMPERATURE ACTUATED MIXING VALVE COMPLYING | | | WITH ASSE 1017 BETWEEN THE WATER HEATERS AND THE HOT | | | WATER DISTRIBUTION SYSTEM AS REQUIRED BY FBC PL 607.1.1 | | | AND 613.1. | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER PX928 | | | PLUMBING INSPECTOR BN2148 | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-246-0882 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-11-02 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2022-11-02 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2022-10-31 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2022-11-02 09:33:34 | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1 | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 22080183 4065 N HAVERHILL RD #B7 | | | | | | 2ND REVIEW | | | | | | PLUMBING COMMENTS: DENIED | | | | | | A SEPARATE PERMIT FOR THE SOLIDS INTERCEPTOR IS | | | REQUIRED TO BE SUBMITTED PRIOR TO ISSUANCE OF THE | | | PRIMARY PERMIT (AS APPLICABLE). YOU CAN SUBMIT AN | | | APPLICATION "TBD" (TO BE DETERMINED) IF YOU DO NOT HAVE | | | A CONTRACTOR SELECTED BY EMAILING A COMPLETED PERMIT | | | APPLICATION TO [email protected] . YOU WILL | | | RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU | | | MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE | | | APPLICATION IS REQUIRED AT THIS TIME. WE RECOMMEND THAT | | | YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME. A | | | SEPARATE PERMIT IS REQUIRED HOWEVER A REVIEW OF THE | | | SYSTEM UNDER THE MAIN PERMIT IS ALSO REQUIRED. | | | AFTER YOU HAVE THE PERMIT(S) GENERATED, PLEASE NOTIFY | | | ME AT [email protected] AND CC SAMANTHA HILL, CHIEF PLANS | | | EXAMINER AT [email protected] AND RYAN BROWN, CHIEF | | | PLUMBING INSPECTOR AT [email protected] VIA EMAIL WITH | | | THE PERMIT NUMBER(S). | | | | | | 1. THE TMV HAS BEEN REMOVED FROM REVISED P-1/HIGH TEMP | | | DOMESTIC WATER HEATER DETAIL. PROVIDE A TEMPERATURE | | | ACTUATED MIXING VALVE COMPLYING WITH ASSE 1017 BETWEEN | | | THE WATER HEATERS AND THE HOT WATER DISTRIBUTION SYSTEM | | | AS REQUIRED BY FBC PL 607.1.1 AND 613.1. | | | | | | 2. SOLIDS INTERCEPTOR: THE PLANS ARE UNCLEAR AS TO | | | WHETHER THE UNIT IS IN AN AREA SUBJECT TO | | | AUTOMOTIVE/HEAVY TRAFFIC. PER WPB FBC 107.2.1, CLARIFY. | | | PER FBC PL 305.7 & 1003.10, PLEASE INDICATE ON THE | | | P-1/SOLIDS INTERCEPTOR SPECIFICATION OPTION C24-HP FOR | | | H20 LIDS IF APPLICABLE. | | | DESIGNER RESPONSE IS THE UNIT IS NOT SUBJECT TO | | | AUTOMOTIVE/HEAVY TRAFFIC | | | NEW COMMENT: PLEASE INDICATE ON THE PLANS | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER PX928 | | | PLUMBING INSPECTOR BN2148 | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-246-0882 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-09-07 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2022-09-07 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2022-09-06 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2022-09-07 17:05:39 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1 | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 22080183 4075 N HAVERHILL RD | | | | | | 1ST REVIEW | | | PLUMBING COMMENTS: DENIED | | | | | | 1. P-2: CONFIRM LOCATION OF EXISTING BACKFLOW PREVENTER | | | ON THE PLAN. IF A NEW BACKFLOW PREVENTER IS REQUIRED, A | | | SEPARATE PERMIT IS REQUIRED AND IS REQUIRED TO BE | | | SUBMITTED PRIOR TO ISSUANCE OF THE PRIMARY PERMIT (AS | | | APPLICABLE). YOU CAN SUBMIT AN APPLICATION "TBD" (TO BE | | | DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR SELECTED BY | | | EMAILING A COMPLETED PERMIT APPLICATION TO | | | [email protected] . YOU WILL RECEIVE INSTRUCTIONS | | | TO PAY FEES AND UPLOAD PLANS. YOU MAY UPLOAD PLANS AND | | | PAY FEES AT A FUTURE DATE, BUT THE APPLICATION IS | | | REQUIRED AT THIS TIME. WE RECOMMEND THAT YOU PAY FEES | | | AND UPLOAD PLANS AT THE SAME TIME. A SEPARATE PERMIT IS | | | REQUIRED HOWEVER A REVIEW OF THE SYSTEM UNDER THE MAIN | | | PERMIT IS ALSO REQUIRED. | | | ***PROVIDE DETAIL AND SCHEDULE FOR NEW BACKFLOW | | | PREVENTER IF APPLICABLE. | | | | | | 2. A SEPARATE PERMIT FOR THE SOLIDS INTERCEPTOR IS | | | REQUIRED TO BE SUBMITTED PRIOR TO ISSUANCE OF THE | | | PRIMARY PERMIT (AS APPLICABLE). YOU CAN SUBMIT AN | | | APPLICATION "TBD" (TO BE DETERMINED) IF YOU DO NOT HAVE | | | A CONTRACTOR SELECTED BY EMAILING A COMPLETED PERMIT | | | APPLICATION TO [email protected] . YOU WILL | | | RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU | | | MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE | | | APPLICATION IS REQUIRED AT THIS TIME. WE RECOMMEND THAT | | | YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME. A | | | SEPARATE PERMIT IS REQUIRED HOWEVER A REVIEW OF THE | | | SYSTEM UNDER THE MAIN PERMIT IS ALSO REQUIRED. | | | | | | 3. PER WPB FBC 107.2.1, PLEASE PROVIDE THE | | | MANUFACTURER'S INSTALLATION MANUAL FOR THE SCHEDULED | | | SOLIDS INTERCEPTOR | | | | | | 4. THE BUILDING DRAIN/SEWER PIPING TO THE INTERCEPTOR | | | IS 6 INCH. PER WPB FBC 107.2.1, PLEASE INDICATE ON THE | | | P-1/SOLIDS INTERCEPTOR SPECIFICATION OPTION 6P FOR 6 | | | INCH INLET/OUTLET | | | | | | 5. PER WPB FBC 107.2.1, PLEASE INDICATE ON THE | | | P-1/SOLIDS INTERCEPTOR SPECIFICATION THE FILTER OPTION | | | TO BE INCORPORATED. | | | | | | 6. P-2/KEYNOTE AND P-3/KEYNOTE 2 INDICATE SOLIDS | | | INTERCEPTOR EFFLUENT SHALL CONNECT TO EXISTING 4 INCH | | | SANITARY; INFLUENT SIZE IS 6 INCH. PER WPB FBC 107.2.1, | | | PLEASE CLARIFY. | | | | | | 7. P-2 AND P-3 SHOWS A P-TRAP AHEAD OF THE SOLIDS | | | INTERCEPTOR. PER FBC PL 901.2.1, A VENT IS REQUIRED | | | DOWNSTREAM OF THE TRAP. | | | | | | 8. THE VENT FOR THE 6 INCH COMBINATION WASTE AND VENT | | | SYSTEM FOR THE CLOTHES WASHERS IS NOTED ON P-2/KEY NOTE | | | 1 AND P-3/KEY NOTE 1 AS A 3 INCH VENT THROUGH THE ROOF. | | | P-3 SANITARY RISER DIAGRAM INDICATES A 2 INCH VENT | | | CONNECTING TO 3 INCH VTR BY MEANS OF BRANCH VENT. PER | | | FBC 906.2, THE VENT SHALL BE 3 INCH. PLEASE CLARIFY AND | | | RECONCILE. | | | | | | 9. SOLIDS INTERCEPTOR: PER WPB FBC 107.2.1, PROVIDE AN | | | ENLARGED PIPING DIAGRAM SHOWING | | | ***A) THE LOCATIONS OF CLEANOUTS AND VENTS AS REQUIRED | | | BY THE MANUFACTURER AND FBC PL 1003.9. | | | ***B) SIZE OF INFLUENT AND EFFLUENT PIPING | | | | | | 10. SOLIDS INTERCEPTOR: PER WPB FBC 107.2.1, PROVIDE A | | | SITE SPECIFIC, DIMENSIONED INSTALLATION DIAGRAM | | | (ELEVATION) SHOWING THE BURIAL DEPTH AND INLET AND | | | OUTLET LOCATIONS, CLEAN OUTS AND SIZES. INCLUDE SURFACE | | | CONDITIONS (I.E. WALKWAY, TRAFFIC AREA, GRASSY AREA). | | | COMPLY WITH MANUFACTURER'S INSTALLATION MANUAL. FBC PL | | | 301.7, 303.2. | | | | | | 11. SOLIDS INTERCEPTOR: THE PLANS ARE UNCLEAR AS TO | | | WHETHER THE UNIT IS IN AN AREA SUBJECT TO | | | AUTOMOTIVE/HEAVY TRAFFIC. PER WPB FBC 107.2.1, CLARIFY. | | | PER FBC PL 305.7 & 1003.10, PLEASE INDICATE ON THE | | | P-1/SOLIDS INTERCEPTOR SPECIFICATION OPTION C24-HP FOR | | | H20 LIDS IF APPLICABLE. | | | | | | 12. MANUFACTURER'S SPECIFICATION/INSTALLATION MANUAL | | | FOR THE FOLLOWING SHALL BE PROVIDED FOR THE FOLLOWING: | | | ***WATER HEATERS | | | ***CLOTHES WASHERS | | | ***SOLIDS INTERCEPTOR | | | ***HEAVY DUTY TRAFFIC LIDS | | | ALL SUBMITTALS SHALL BE APPROVED AND STAMPED BY THE | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE- WPB FBC | | | 107.2.1, 107.3.4. SUBMITTALS MAY BE DEFERRED IN | | | ACCORDANCE WITH SECTION WPB FBC 107.3.4.1. DEFERRED | | | SUBMITTALS SHALL BE LISTED ON THE PLANS. SUBMITTALS | | | SHALL BE ON SITE PRIOR TO FIRST INSPECTION. PROCEED AT | | | YOUR OWN RISK. | | | | | | 13. A-1/ROOM FINISH SCHEDULE FOR BATHROOM WALLS: PER | | | FBC 1210.2.2, FBC PL 310.3, WALLS WITHIN 2 FEET OF | | | WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NON-ABSORBENT | | | SURFACE TO A HEIGHT NOT LESS THAN 4 FEET ABOVE THE | | | FLOOR. SECTION 1210.2.2 STIPULATES THAT THE MATERIAL BE | | | "HARD." THE INTENT OF THIS SECTION IS THAT THE | | | SURROUNDING MATERIAL SHOULD NOT BE OF A TYPE THAT IS | | | EASILY DAMAGED SUCH THAT THE MATERIAL COULD BECOME | | | ABSORBENT AND THUS, NOT READILY CLEANABLE AND | | | SANITIZED. PAINTED DRYWALL, EVEN WHERE COATED WITH | | | HIGHLY DURABLE PAINTS, DOES NOT MEET THE INTENT OF | | | SECTION 1210.2.2. THE TYPICAL MATERIALS USED FOR THIS | | | APPLICATION ARE CERAMIC TILE, FIBERGLASS REINFORCED | | | PLASTIC (FRP) PANELS, PHENOLIC PANELS, LAMINATED | | | PLASTIC PANELS, PAINTED STEEL AND STAINLESS STEEL. | | | | | | 14. A-1/ROOM FINISH SCHEDULE FOR JANITORS ROOM: AMEND | | | NOTE TO STATE *FRP TO 4 FEET MINIMUM AFF. FBC 1210.2.2, | | | FBC PL 310.3 | | | | | | 15. P-1/PLUMBING NOTE 15: PER WPB FBC 107.2.1 AND FBC | | | PL 604.9, REPLACE THE WORDS "APPROVED AIR CHAMBERS" | | | WITH THE WORDS "WATER HAMMER ARRESTORS CONFORMING TO | | | ASSE 1010" | | | | | | 16. P-3: PER WPB FBC 107.2.1, PROVIDE WATER PIPE SIZES | | | FOR CLOTHES WASHER BATTERY WATER PIPING. | | | | | | 17. 18. P-3: PER WPB FBC 107.2.1, PROVIDE SIZE(S) FOR | | | CLOTHES WASHER BATTERY SANITARY PIPING. | | | | | | 19. P-3: PER WPB FBC 107.2.1, IDENTIFY THE FLOOR SINKS | | | ON THE PLAN, PROVIDE SIZE. | | | | | | 20. PER FBC EC C404.5.1 AND TABLE C404.5.1, THE 1/2 | | | -INCH HOT WATER PIPE TO THE LAVATORIES SHALL NOT EXCEED | | | 2 FEET FROM THE HOT WATER SOURCE. | | | | | | 21. ALL COMPONENTS IN THE DOMESTIC WATER SYSTEM SHALL | | | BE LEAD FREE IN ACCORDANCE WITH FBC PL 605.2 AND | | | 605.2.1. PER WPB FBC 107.2.1, PROVIDE NOTE ON PLANS | | | STATING THE SAME. | | | | | | 22. PER WPB FBC 107.2.1, PROVIDE PIPE HANGER DETAIL | | | WITH A NOTE STATING, "HORIZONTAL PIPE SHALL BE | | | SUPPORTED IN ACCORDANCE WITH FBC PL TABLE 308.5." | | | | | | 23. PROVIDE ENERGY EFFICIENCY FOR WATER HEATERS; COMPLY | | | WITH FBC EC TABLE C404.2 | | | | | | 24. A THERMOSTATIC MIXING VALVE IS SHOWN ON P-1/HIGH | | | TEMP DOMESTIC WATER HEATER DETAIL BUT NOT ON THE WATER | | | DISTRIBUTION RISER AND PLAN VIEWS. PER WPB FBC 107.2.1, | | | PLEASE CLARIFY AND RECONCILE. | | | | | | 25. P-1/HIGH TEMP DOMESTIC WATER HEATER DETAIL: PER WPB | | | FBC 107.2.1, PROVIDE A SCHEDULE AND SPECIFICATION FOR | | | THE TMV. | | | | | | 26. P-1/TANKLESS GAS WATER HEATER DETAIL: PER WPB FBC | | | 107.2.1, PROVIDE MEANS AND POINT OF TERMINATION FOR | | | CONDENSATE DRAIN. | | | | | | 27. PER WPB FBC 107.2.1, TO SHOW COMPLIANCE WITH FBC PL | | | 704.1, PROVIDE NOTE STATING "HORIZONTAL DRAINAGE PIPING | | | LESS THAN 3 INCH DIAMETER SHALL HAVE A MINIMUM SLOPE OF | | | 1/4 INCH PER FOOT. 3 INCH TO 6 INCH DIAMETER SHALL HAVE | | | A MINIMUM SLOPE OF 1/8 INCH PER FOOT." | | | | | | 28. M-1/MECHANICAL PLAN NOTE H CALLS FOR A/C CONDENSATE | | | TO NEAREST ROOF DRAIN OR INDIRECT WASTE. PER WPB CODE | | | OF ORDINANCE CHAPTER 90, ARTICLE 3, SECTION 90-12B5, | | | A/C CONDENSATE (INTERPRET THIS AS ANY CONDENSATION FROM | | | EVAPORATOR COILS) SHALL NOT DISCHARGE TO THE CITY | | | UTILITIES SANITARY SEWAGE INFRASTRUCTURE WITHOUT | | | PERMISSION FROM THE UTILITIES DEPARTMENT. YOU MAY | | | CONTACT MR. RICK ROSSANO IN ENGINEERING AT 561-494-1098 | | | FOR ADDITIONAL INFORMATION. MOVING FORWARD, REMOVE | | | INDIRECT WASTE FROM THE NOTE. FBC PL 314.2.1. | | | | | | 29. PER WPB FBC 107.2.1, PROVIDE RECIRCULATING PUMP | | | SCHEDULE & DETAIL. INTEGRATE WITH P-1/HIGH TEMP | | | DOMESTIC WATER HEATER DETAIL. | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER PX928 | | | PLUMBING INSPECTOR BN2148 | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-246-0882 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2023-02-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-02-24 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-02-24 |
Time |
11:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2023-01-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-01-17 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-01-17 14:25:17 | DIGITAL SIGNATURES FOR PLUMBING PLANS ARE VALID. JS | | 2023-01-17 07:46:13 | ELECTRICAL SHEETS. FLORIDA ADMINISTRATIVE CODE | | | 61G15-23.005 (3)(C) PLANS IN THE FILE FOLDER, SCANNED, | | | FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE OF THE | | | LICENSEE???S SIGNATURE SHALL NOT BE USED ON | | | ELECTRONIC/DIGITALLY SIGNED AND SEALED ENGINEERING | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | 61G15-23.004 PROCEDURES FOR SIGNING AND SEALING | | | ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES), | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS, REQUIRE 3RD | | | PARTY VERIFICATION. | | | | | 2023-01-13 15:12:07 | ORIGINAL DIGITALLY SIGNED DRAWINGS REQUIRED FOR THE | | | MECHANICAL DRAWINGS. FS 471/481 ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-11-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-11-13 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-11-13 |
Time |
17:09 |
Sent To |
|
|
| Notes |
| 2022-11-13 17:09:55 | PLANS ARE NOT DIGITALLY SIGNED JLEAHY | | 2022-11-08 14:04:47 | MECHANICAL DRAWINGS ARE NOT DIGITALLY SIGNED. PLEASE | | | SUBMIT THE ORIGINALLY DIGITALLY SIGNED DRAWINGS. ME | | 2022-11-02 09:48:11 | PLUMBING AND GAS PLANS ARE NOT DIGITALLY SIGNED. PLEASE | | | PROVIDE DIGITALLY SIGNED PLANS. JS |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-02 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-02 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2022-09-06 11:59:33 | PLUMBING AND GAS PLANS ARE NOT DIGITALLY SIGNED. PLEASE | | | PROVIDE DIGITALLY SIGNED PLANS. JS | | 2022-09-02 10:00:36 | DIGITALLY SUBMITTED DOCUMENTS MUST BE DIGITALLY SIGNED | | | BY THE DESIGNER. PROVIDE DIGITALLY SIGN DOCUMENTS. FS | | | 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-09-08 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-09-08 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-09-08 |
Time |
10:31 |
Sent To |
|
|
| Notes |
|
|