Plan Review Details - Permit 22080081
Plan Review Stops For Permit 22080081
Review Stop E ELECTRICAL
Rev No 1 Status N Date 2022-08-05 Cont ID  
Sent By ccole Date 2022-08-05 Time 13:39 Rev Time 0.00
Received By ccole Date 2022-08-05 Time 13:39 Sent To  
Notes
2022-08-05 13:40:27GAS WATER HEATER.

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2022-08-12 Cont ID  
Sent By ccole Date 2022-08-12 Time 11:47 Rev Time 0.00
Received By ccole Date 2022-08-12 Time 11:21 Sent To  
Notes
2022-08-12 11:49:522ND REVIEW FBC-2020 RES. FUEL GAS
 PERMIT- 22080081
 8/12/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. COMMENTS #1 & 2 FROM THE
 1ST REVIEW STILL EXIST- PLEASE COMPLY.
  
 1) THE SCOPE OF WORK FOR THE PERMIT APPEARS TO BE A
 NEW, NOT REPLACED 180,000 BTU GAS-FIRED TANKLESS WATER
 HEATER TO BE INSTALLED ON THE EXTERIOR OF THE
 RESIDENCE. BASED ON WPB BUILDING DEPARTMENT RECORD
 PLANS UNDER PERMIT-03061107, THE EXISTING WATER HEATER
 IS A 40,000 BTU STORAGE TYPE WATER HEATER INSTALLED ON
 THE INTERIOR OF THE RESIDENCE. THE RISER DRAWING
 SUBMITTED UNDER PERMIT- 22080050 FOR A GAS-FIRED
 GENERATOR SHOWS A 76,000 BTU HEATER INSIDE THE HOUSE.
 REFER TO SECS. G2412.3 & G2412.4 FBC RES AND PROVIDE A
 COMPLETE GAS RISER FOR THE RESIDENCE THAT INCLUDES THE
 FOLLOWING INFORMATION:
  
 A) DELIVERY PRESSURE AT THE METER.
 B) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS.
 C) TYPES AND SIZES OF PIPING SUPPLYING THE EXISTING
 APPLIANCES AND THE NEW WATER HEATER.
 D) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 E) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 F) LOCATIONS OF REGULATORS & SHUTOFF VALVES.
 G) OUTLET PRESSURES AT REGULATORS.
 H) PIPE SIZING TABLES.
  
 2) PROVIDE A BASIC FLOOR PLAN DRAWING SHOWING THE
 LOCATION OF THE WATER HEATER WITH REQUIRED EXHAUST
 OUTLET CLEARANCES TO AIR INTAKES AND OPERABLE OPENINGS
 INTO THE BUILDING SUCH AS WINDOWS AND DOORS- SEC.
 G2439.1 FBC RES.
 CORRECTED PLANS.
  
 3) THE PLUMBING PERMIT HAS BEEN CONVERTED A GAS PERMIT.
 PLEASE SUBMIT A SUB-PERMIT APPLICATION FOR THE WATER
 HEATER- SEC. 105.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-08-05 Cont ID  
Sent By ccole Date 2022-08-05 Time 13:29 Rev Time 0.00
Received By ccole Date 2022-08-05 Time 13:29 Sent To  
Notes
2022-08-05 13:30:391ST REVIEW FBC-2020 RES. FUEL GAS
 PERMIT- 22080081
 8/5/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE SCOPE OF WORK FOR THE PERMIT APPEARS TO BE A
 NEW, NOT REPLACED 180,000 BTU GAS-FIRED TANKLESS WATER
 HEATER TO BE INSTALLED ON THE EXTERIOR OF THE
 RESIDENCE. BASED ON WPB BUILDING DEPARTMENT RECORD
 PLANS UNDER PERMIT-03061107, THE EXISTING WATER HEATER
 IS A 40,000 BTU STORAGE TYPE WATER HEATER INSTALLED ON
 THE INTERIOR OF THE RESIDENCE. THE RISER DRAWING
 SUBMITTED UNDER PERMIT- 22080050 FOR A GAS-FIRED
 GENERATOR SHOWS A 76,000 BTU HEATER INSIDE THE HOUSE.
 REFER TO SECS. G2412.3 & G2412.4 FBC RES AND PROVIDE A
 COMPLETE GAS RISER FOR THE RESIDENCE THAT INCLUDES THE
 FOLLOWING INFORMATION:
  
 A) DELIVERY PRESSURE AT THE METER.
 B) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS.
 C) TYPES AND SIZES OF PIPING SUPPLYING THE EXISTING
 APPLIANCES AND THE NEW WATER HEATER.
 D) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 E) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 F) LOCATIONS OF REGULATORS & SHUTOFF VALVES.
 G) OUTLET PRESSURES AT REGULATORS.
 H) PIPE SIZING TABLES.
  
 2) PROVIDE A BASIC FLOOR PLAN DRAWING SHOWING THE
 LOCATION OF THE WATER HEATER WITH REQUIRED EXHAUST
 OUTLET CLEARANCES TO AIR INTAKES AND OPERABLE OPENINGS
 INTO THE BUILDING SUCH AS WINDOWS AND DOORS- SEC.
 G2439.1 FBC RES.
 CORRECTED PLANS.
  
 3) SUBMIT A GAS PERMIT APPLICATION- SEC. 105.1 WPB. THE
 PLUMBING PERMIT APPLICATION WILL BE CONVERTED TO A
 SUB-PERMIT WHEN THE PRIMARY GAS PERMIT IS RECEIVED.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2022-08-12 Time   Rev Time 0.00
Received By aoliver Date 2022-08-11 Time 09:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2022-08-05 Time   Rev Time 0.00
Received By cdecoeur Date 2022-08-04 Time 06:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-08-12 Cont ID  
Sent By ccole Date 2022-08-12 Time 11:45 Rev Time 0.00
Received By ccole Date 2022-08-12 Time 11:21 Sent To  
Notes
2022-08-12 11:47:291ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 22080081
 8/12/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE PLUMBING PERMIT HAS BEEN CONVERTED TO A PRIMARY
 GAS PERMIT. PLEASE SUBMIT A PLUMBING SUB-PERMIT
 APPLICATION FOR THE WATER HEATER- SEC. 105.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-08-05 Cont ID  
Sent By ccole Date 2022-08-05 Time 13:33 Rev Time 0.00
Received By ccole Date 2022-08-05 Time 10:02 Sent To  
Notes
2022-08-05 13:43:30THE PLUMBING PERMIT CANNOT BE ISSUED AT THIS TIME. IT
 WILL BE CHANGED FROM A PRIMARY TO A SUB-PERMIT WHEN THE
 PRIMARY GAS PERMIT AND PLANS ARE APPROVED. SEE GAS
 COMMENTS.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2022-08-05 Cont ID  
Sent By ccole Date 2022-08-05 Time 13:28 Rev Time 0.00
Received By ccole Date 2022-08-05 Time 13:28 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy