|
 |
 |
 |
 |
 |
Plan Review Details - Permit 22080033
| Plan Review Stops For Permit 22080033 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-12-05 |
|
|
Cont ID |
|
| Sent By |
eroseber |
Date |
2022-12-05 |
Time |
20:20 |
Rev Time |
0.00 |
| Received By |
eroseber |
Date |
2022-12-05 |
Time |
20:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-10-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-10-22 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-10-22 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2022-10-22 16:09:27 | [email protected] | | | [email protected] | | | | | | 1. CONTRACTOR FURNISHED INFORMATION, WHICH ENGINEERED | | | DESIGN PRESSURE REQUIREMENTS ARE BASED ON, STATE LOWEST | | | ELEVATION INSTALLATION TO BE 10'. AS THIS IS A | | | PENTHOUSE WITH 170' MRH, THIS DOES NOT APPEAR TO BE | | | CORRECT DATA. PLEASE VERIFY AND RESUBMIT CORRECTION OR | | | CLARIFICATION. FBC 107.2 | | | 2. PLEASE PROVIDE A FLASHING DETAIL, OR ADD A NOTE TO | | | THE PLAN, DEMONSTRATING COMPLIANCE WITH FBC R 703.4 OR | | | FBC B 1405.4. | | | DIGITAL SIGNATURE- APPROVED PENDING COMMENT RESPONSE. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
P |
Date |
2022-12-05 |
|
|
Cont ID |
|
| Sent By |
eroseber |
Date |
2022-12-05 |
Time |
20:21 |
Rev Time |
0.00 |
| Received By |
eroseber |
Date |
2022-11-16 |
Time |
09:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-10-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-10-22 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-09-27 |
Time |
09:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-11-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-11-16 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-11-16 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2022-11-16 10:04:36 | SIGNED AND SEALED CALCULATIONS ON PAPER SENT TO | | | STORAGE/CC. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-08-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-08-03 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-08-03 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2022-08-03 16:56:12 | SIGNED AND SEALED CALCULATIONS ON PAPER SENT TO | | | STORAGE. RM |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |