| Plan Review Stops For Permit 22071422 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2022-08-18 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-08-18 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-08-18 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2022-08-18 13:38:31 | ADDRESS IS CORRECTFOR THIS PROJECT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-10-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-10-06 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-10-06 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2022-10-06 10:04:48 | 10/06/22 RECEIVED EMAIL FROM ELIZABETH TUKE (OWNER) TO | | | APPROVE BUILDING WITH PROVISO. JG. | | | | | | BUILDING REVIEW APPROVED WITH PROVISO | | | (NOTE; PROVIDE INFORMATION FOR REVIEW PRIOR TO | | | INSTALLATION TO AVOID CONFLICTS/DELAYS): | | | 1- REVISE BEDROOM EGRESS WINDOW SIZE TO COMPLY WITH | | | SEC. R310.2.1 FBC-RESIDENTIAL. | | | | | | 2- PROVIDE PRODUCT APPROVAL FOR: | | | A)INSWING ENTRY DOOR AS SHOWN ON PLANS. | | | B)SINGLE HUNG WINDOWS. | | | C)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE | | | IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. SEE CITY SAMPLE. | | | D)OVERHEAD GARAGE DOOR AS SHOWN ON PLANS. | | | | | | 3- DESIGNER OF RECORD TO APPROVE ALL PRODUCT APPROVALS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-10-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-10-04 |
Time |
18:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-10-04 |
Time |
17:45 |
Sent To |
|
|
| Notes |
| 2022-10-04 18:16:47 | RESIDENTIAL (R3) ALTERATION SECOND BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #22071422 | | | 236 EDGEWOOD DR (GARAGE/APARTMENT). | | | | | | | | | NOTE: | | | RESPONSE LETTER SUBMITTED IS FOR THE MAIN HOUSE | | | COMMENTS NOT FOR THE GARAGE/APARTMENT. | | | | | | | | | ORIGINAL COMMENT: | | | 1- BEDROOM EGRESS WINDOWS DON'T COMPLY WITH THE MINIMUM | | | CLEAR OPENING REQUIREMENTS OF SEC. R310.2.1 | | | FBC-RESIDENTIAL. REVISE AS REQUIRED. | | | | | | RESPONSE: | | | 1-SINGLE HUNG BEDROOM EGRESS WINDOWS SIZE (3'-0" X | | | 5'-0")DOESN'T SEEM TO COMPLY WITH THE MINIMUM CLEAR | | | HEIGHT OPENING REQUIREMENTS OF SEC. R310.2.1 | | | FBC-RESIDENTIAL. REVISE AS REQUIRED OR PROVIDE | | | MANUFACTURER'S SPECIFICATIONS SHOWING COMPLIANCE ALL | | | THE EGRESS REQUIREMENTS. | | | NOTE: TYPICALLY, 63" HIGH SINGLE HUNG WINDOWS ARE THE | | | ONES THAT PROVIDE THE 24" CLEAR HEIGHT OPENING. | | | | | | 2- PRODUCT APPROVALS | | | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 | | | FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A)INSWING ENTRY DOOR AS SHOWN ON PLANS. | | | B)SINGLE HUNG WINDOWS. | | | C)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE | | | IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. SEE CITY SAMPLE. | | | D)OVERHEAD GARAGE DOOR AS SHOWN ON PLANS. | | | | | | 3- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-08-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-08-19 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-08-19 |
Time |
17:05 |
Sent To |
|
|
| Notes |
| 2022-08-19 17:44:37 | RESIDENTIAL (R3) BUILDING REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #22071422 | | | 236 EDGEWOOD DR (GARAGE/APARTMENT) | | | | | | NOTE: | | | LEVEL 3 ALTERATION. SEC. 604 FBC-EXISTING BUILDING. | | | SEC. 901.2 FBC-EXISTING BUILDING. SEC. 801.3 | | | FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, | | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | | REQUIREMENTS OF THE FLORIDA BUILDING CODE. | | | | | | 1- BEDROOM EGRESS WINDOWS DON'T COMPLY WITH THE MINIMUM | | | CLEAR OPENING REQUIREMENTS OF SEC. R310.2.1 | | | FBC-RESIDENTIAL. REVISE AS REQUIRED. | | | | | | 2- PRODUCT APPROVALS | | | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 | | | FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A)INSWING ENTRY DOOR AS SHOWN ON PLANS. | | | B)SINGLE HUNG WINDOWS. | | | C)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE | | | IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. SEE CITY SAMPLE. | | | D)OVERHEAD GARAGE DOOR AS SHOWN ON PLANS. | | | | | | 3- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | 4- ARCHITECT TO CLARIFY WHY THE EXTERIOR ELEVATIONS | | | SHOW A SECOND FLOOR AT +9'-6" IF THIS IS ONLY ONE STORY | | | BUILDING. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-10-03 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-10-03 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-10-03 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-08-05 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-08-05 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2022-08-05 16:19:43 | ELECTRIC REVIEW FAILED | | | 1) PLEASE DETAIL AN OUTDOOR RECEPTACLE(S) TO COMPLY | | | WITH NEC 210.52 (E)(1) AND NEC 210. 63 | | | 2) PLEASE DETAIL THE REQUIRED RECEPTACLE IN THE LIVING | | | ROOM WITHIN 6 FEET OF THE FRONT DOOR TO COMPLY WITH NEC | | | 210.52 RECEPTACLE SPACING | | | 3) PLEASE DETAIL GROUNDING ELECTRODE SYSTEM FOR MAIN | | | HOUSE ELECTRIC PANEL TO COMPLY WITH NEC 250.32 | | | 4) PLEASE REMOVE CONFUSING NOTE ON PLANS DETAILING, | | | PROPOSED ADDITION, TO MAIN HOUSE, AND HIGHLIGHT NOTE | | | STATING, THIS CONSTRUCTION DOCUMENT SET IS FOR GUEST | | | HOUSE. FBC 107.2 | | | | | | | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-10-06 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-10-06 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-10-06 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2022-10-06 14:53:30 | CONDITIONS SATISFIED PER ATTACHED EMAIL. | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-08-17 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-08-17 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-08-17 |
Time |
09:43 |
Sent To |
|
|
| Notes |
| 2022-08-17 09:44:58 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | PLEASE INDICATE THAT GUEST HOUSE DOOR WILL BE RETAINED | | | AND USED SOMEWHERE ON PROPERTY PER HPB DECISION | | | CONDITIONS. PLEASE ALSO INDICATE THAT ALL GRIDS ON | | | WINDOWS WILL BE EXTERNALLY APPLIED AND HAVE A | | | DIMENSIONAL PROFILE (EITHER PYRAMID OR OGEE) | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-10-11 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-10-11 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-09-19 |
Time |
06:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-08-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-08-19 |
Time |
17:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-08-01 |
Time |
05:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-09-20 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-20 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-20 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2022-08-08 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-08 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-08 |
Time |
11:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-09-20 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-09-20 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-09-20 |
Time |
07:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-08-01 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-08-01 |
Time |
08:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-09-20 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-20 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-20 |
Time |
09:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-08-05 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-08-05 |
Time |
16:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-10-06 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-10-06 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-10-06 |
Time |
14:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-08-17 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-08-17 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-08-17 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2022-08-17 09:43:47 | GARAGE APARTMENT PERMITTED PER GREEN CARD | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|