| Plan Review Stops For Permit 22071418 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-11-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-23 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-11-23 |
Time |
11:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-18 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-18 |
Time |
16:32 |
Sent To |
|
|
| Notes |
| 2022-10-18 16:48:45 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | BU1635 BN4338 | | | ASFPM CFM US-21-11935 | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | COMMENTS FROM 1ST REVIEW HAVE NOT BEEN ADDRESSED. SEE | | | BELOW: | | | | | | 1. PROVIDE AN EXISTING FLOOR PLAN. NOTE ON FLOOR PLAN | | | PG. 1 OF 3 STATES "WALLS ADDED OR REMOVED AS SHOWN" BUT | | | THERE IS NO LEGEND PROVIDED. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2.PROVIDE AN ENERGY SUBMITTAL | | | FBCE-103.2.1.1 RESIDENTIAL LESS THAN OR EQUAL TO 3 | | | STORIES. | | | FBC EC-R101.5.1.1.2 BUILDING THERMAL ENVELOPE | | | ALTERNATIVE. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | | | 3. NOA 21-0728.01 FOR THE SGD HAS EXPIRED. | | | PROVIDE THE FL PRODUCT APPROVALS OR MIAMI-DADE NOA FOR | | | THE PROPOSED SGD. | | | FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, | | | EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. | | | NOTE: NOA?S DO NOT HAVE COVER SHEETS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 4. | | | | | | 5. | | | | | | 6. | | | | | | 7. EXTERIOR DOORS/LANDINGS | | | R311.3 FLOORS AND LANDINGS AT EXTERIOR DOORS. | | | THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH | | | EXTERIOR DOOR. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-09-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-09-03 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-09-02 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2022-09-03 08:55:08 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | BU1635 BN4338 | | | ASFPM CFM US-21-11935 | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE AN EXISTING FLOOR PLAN. NOTE ON FLOOR PLAN | | | PG. 1 OF 3 STATES "WALLS ADDED OR REMOVED AS SHOWN" BUT | | | THERE IS NO LEGEND PROVIDED. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2.PROVIDE AN ENERGY SUBMITTAL | | | FBCE-103.2.1.1 RESIDENTIAL LESS THAN OR EQUAL TO 3 | | | STORIES. | | | FBC EC-R101.5.1.1.2 BUILDING THERMAL ENVELOPE | | | ALTERNATIVE. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | | | 3. NOA 21-0728.01 FOR THE SGD HAS EXPIRED. | | | PROVIDE THE FL PRODUCT APPROVALS OR MIAMI-DADE NOA FOR | | | THE PROPOSED SGD. | | | FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, | | | EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. | | | NOTE: NOA?S DO NOT HAVE COVER SHEETS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 4.SMOKE ALARMS | | | R314.2.2ALTERATIONS, REPAIRS AND ADDITIONS. | | | WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC R314. | | | | | | 5.HOT WATER | | | PLEASE PROVIDE THE SOURCE OF HOT WATER PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 107.2.1. INFORMATION ON | | | CONSTRUCTION DOCUMENTS. SECTION P2801.1 FBC RES. | | | P2801.1REQUIRED. | | | HOT WATER SHALL BE SUPPLIED TO PLUMBING FIXTURES AND | | | PLUMBING APPLIANCES INTENDED FOR BATHING, WASHING OR | | | CULINARY PURPOSES. | | | | | | 6. PROVIDE A SITE PLAN.... | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | | | | 7. EXTERIOR DOORS/LANDINGS | | | R311.3 FLOORS AND LANDINGS AT EXTERIOR DOORS. | | | THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH | | | EXTERIOR DOOR. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2022-12-08 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-12-08 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-12-08 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-11-07 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-11-07 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-11-07 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2022-11-07 10:35:04 | ELECTRIC REVIEW FAILED | | | | | | 1) ELECTRICAL PLAN IS STILL NOT SIGNED BY THE DESIGN | | | PROFFESIONAL. WPB 107.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2022-09-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-09-30 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-09-30 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2022-09-30 13:16:11 | PAGE NOT DIGITALLY SIGNED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-08-29 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-08-29 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-08-29 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2022-08-29 13:44:10 | ELECTRIC REVIEW FAILED | | | 1) PLEASE PROVIDE ELECTRICAL RISER DIAGRAM, ELECTRIC | | | SITE PLAN DETAILING ALL ELECTRICAL AND MECHANICHAL | | | EQUIPMENT (AIR CONDITIONING EQUIPMENT MAY NOT BE | | | REFLECTED AS TO BE DETERMINED) PLEASE REFLECT ALL | | | EQUIPMENT IN PANEL SCHEDULES AND LOAD CALCULATIONS | | | (RANGE,DRYER,MINI SPLITS AND WATERHEATER LOADS APPEAR | | | TO BE INCORRECT AS PER NEC 220) FBC 107.2 NEC 215.5 220 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-11-28 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-11-28 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-11-28 |
Time |
12:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
F |
Date |
2022-10-14 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-10-14 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-10-14 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2022-10-14 10:39:19 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | WINDOWS APPROPRIATE FOR PROJECT, HOWEVER, EXTERNAL | | | MUNTINS NEED TO BE DIMENSIONAL. LISTED AS ES-1014 | | | (FLAT), NEEDS TO BE ES- 1015 (OGEE). PLEASE REVISE. | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-08-25 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-08-25 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-08-25 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2022-08-25 11:15:34 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | NOT ENOUGH INFORMATION PROVIDED ABOUT PROPOSED WINDOWS. | | | PLEASE SUBMIT ELEVATIONS AND A CONTRACT OR WINDOW | | | SCHEDULE FOR WINDOWS, PLEASE ALSO INDICATE GLASS COLOR, | | | FRAME COLOR, AND MUNTIN PROFILE | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-12-08 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-12-08 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-11-29 |
Time |
09:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-11-28 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-11-28 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-10-27 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-18 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-09-22 |
Time |
08:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-09-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-09-03 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-08-17 |
Time |
06:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-11-04 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-11-04 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-11-04 |
Time |
10:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-09-23 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-23 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-23 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2022-09-23 11:53:26 | PLEASE ADDRESS PREVIOUS REVIEW COMMENTS BELOW: | | | | | | SHEET 1 OF 3 INDICATES IN THE GENERAL SCOPE OF WORK | | | NOTES THAT THE MECHANICAL SCOPE OF WORK IS TO ADD 5 | | | ZONE MINI SPLIT SYSTEM AS SHOWN. SHEET M-1 IS A DRAWING | | | OF AN AHU WITH DUCTWORK GOING THROUGHOUT THE RESIDENCE | | | TO EACH ROOM. WE HAVE NO RECORDS OF A MECHANICAL SYSTEM | | | PREVIOUSLY BEING PERMITTED FOR THIS HOME. PROVIDE A | | | CORRECTED SCOPE OF WORK FOR THIS MECHANICAL SYSTEM | | | INCLUDING THE ENERGY CALCULATIONS, THE MECHANICAL | | | EQUIPMENT SIZING CALCULATIONS AND AN ACCURATE | | | MECHANICAL DRAWING INDICATING WHAT IS BEING INSTALLED | | | AT THE RESIDENCE. THE DOCUMENTS SUBMITTED MUST BE | | | SIGNED BY THE DESIGNER. FBC 107.3.5 | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-08-19 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-19 |
Time |
05:23 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-19 |
Time |
05:23 |
Sent To |
|
|
| Notes |
| 2022-08-19 05:33:38 | SHEET 1 OF 3 INDICATES IN THE GENERAL SCOPE OF WORK | | | NOTES THAT THE MECHANICAL SCOPE OF WORK IS TO ADD 5 | | | ZONE MINI SPLIT SYSTEM AS SHOWN. SHEET M-1 IS A DRAWING | | | OF AN AHU WITH DUCTWORK GOING THROUGHOUT THE RESIDENCE | | | TO EACH ROOM. WE HAVE NO RECORDS OF A MECHANICAL SYSTEM | | | PREVIOUSLY BEING PERMITTED FOR THIS HOME. PROVIDE A | | | CORRECTED SCOPE OF WORK FOR THIS MECHANICAL SYSTEM | | | INCLUDING THE ENERGY CALCULATIONS, THE MECHANICAL | | | EQUIPMENT SIZING CALCULATIONS AND AN ACCURATE | | | MECHANICAL DRAWING INDICATING WHAT IS BEING INSTALLED | | | AT THE RESIDENCE. THE DOCUMENTS SUBMITTED MUST BE | | | SIGNED BY THE DESIGNER. FBC 107.3.5 | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2022-11-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-11-30 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-11-30 |
Time |
12:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2022-10-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-10-31 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-10-31 |
Time |
10:17 |
Sent To |
|
|
| Notes |
| 2022-10-31 11:06:55 | 3RD REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 22071418 | | | 10/31/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED | | | | | | 1) THE PREVIOUS SHEET 2 PLUMBING PLAN HAS BEEN | | | ABANDONED. THE NEW SANITARY ISOMETRICS ON NEW SHEET 3 | | | ARE MISLABELED AS SUPPLY ISOMETRICS AND HAVE THE | | | FOLLOWING DEFICIENCIES- | | | | | | A) THERE IS ONLY ONE EXISTING VENT SHOWN FOR BOTH THE | | | MASTER BATHROOM AND KITCHEN FIXTURES- SEC. P3101.2.1 | | | FBC RES. PROVIDE A HORIZONTAL WET VENT FOR THE BATHROOM | | | FIXTURES IN ACCORDANCE WITH SEC. P3108.1. THE LAVATORY | | | VENT CAN SERVE AS THE VENT FOR ALL THE BATHROOM | | | FIXTURES PROVIDING THAT THE LAVATORY FIXTURE DRAIN | | | CONNECTS AT A POINT UPSTREAM OF THE OTHER FIXTURE DRAIN | | | CONNECTIONS, WITH THE EXCEPTION OF ONE FIXTURE | | | PERMITTED TO BE CONNECTED UPSTREAM OF THE LAV DRAIN | | | CONNECTION- SEC. P3108.2.1. THE CURRENT PLAN SHOWS TWO | | | FIXTURES LABELED AS TOILETS CONNECTING UPSTREAM. ONE OF | | | THE FIXTURES SHOULD BE LABELED SHOWER. | | | | | | B) THE DRAIN FROM THE DISHWASHER TYPICALLY CONNECTS TO | | | THE SINK DRAIN VIA AN AIR GAP AND ONE SINGLE VENT SHALL | | | BE PROVIDED FOR BOTH OF THE FIXTURES. THE SINK FIXTURE | | | DRAIN SHALL CONNECT TO THE EXISTING BUILDING DRAIN | | | DOWNSTREAM OF THE BATHROOM WET VENT- SECS. P2717.1, | | | P2717.2, P3107.1 & P3108.2.1. | | | | | | C) NO VENTING IS SHOWN FOR THE FIXTURES IN THE HALL | | | BATHROOM. REFER TO COMMENT 1A ABOVE FOR CODE SECTIONS | | | TO REVIEW AND REVISE THE RISER ACCORDINGLY. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-09-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-09-23 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-09-23 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2022-09-23 15:59:25 | 2ND REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 22071418 | | | 9/23/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. COMMENTS FROM THE 1ST | | | REVIEW ARE LISTED BELOW. NO CORRECTED PLUMBING PLANS | | | WERE UPLOADED FOR REVIEW. | | | | | | 1) SHEET 3: PROVIDE PLUMBING RISER DRAWINGS- SEC. | | | 107.3.5.3 WPB. | | | | | | 2) SHEET 3: SHOW THE REQUIRED SHOWER PAN LINER AND | | | LINER SLOPE IN THE DETAIL- SEC. P2801.1 FBC RES. | | | | | | 3) SHEET 3: SHOW THE SOURCE OF THE HOT WATER- EXISTING | | | OR REPLACED WATER HEATER- SEC. P2709.1 FBC RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-08-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-19 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-19 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2022-08-19 10:02:31 | 2ND REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 22071418 | | | 8/19/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET 3: PROVIDE PLUMBING RISER DRAWINGS- SEC. | | | 107.3.5.3 WPB. | | | | | | 2) SHEET 3: SHOW THE REQUIRED SHOWER PAN LINER AND | | | LINER SLOPE IN THE DETAIL- SEC. P2801.1 FBC RES. | | | | | | 3) SHEET 3: SHOW THE SOURCE OF THE HOT WATER- EXISTING | | | OR REPLACED WATER HEATER- SEC. P2709.1 FBC RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
N |
Date |
2022-12-08 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-12-08 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-12-08 |
Time |
16:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-11-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-11-23 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-11-23 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2022-11-23 15:46:03 | ALL PLAN PAGES SIGNED BY CONTRACTORS. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-18 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-18 |
Time |
16:32 |
Sent To |
|
|
| Notes |
| 2022-10-18 16:46:50 | 2ND SIGNATURE REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | 1.SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | | 481, F.S. & 61G1. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | 2022-09-30 13:17:12 | ELECTRICAL PLAN NOT SIGNED. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-08-19 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-19 |
Time |
05:33 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-19 |
Time |
05:33 |
Sent To |
|
|
| Notes |
| 2022-08-19 05:34:40 | THE DRAWINGS MUST BE DIGITALLY SIGNED BY THE DESIGNER. | | | 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-11-28 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-11-28 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-11-28 |
Time |
12:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2022-10-14 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-10-14 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-10-14 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2022-10-14 10:39:46 | NO LANDSCAPE PERMIT IN REVIEW SYSTEM, SEE PREVIOUS | | | COMMENT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-08-25 |
|
|
Cont ID |
|
| Sent By |
ahamilto |
Date |
2022-08-25 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-08-25 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2022-08-25 11:17:48 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | THE VALUE OF CONSTRUCTION EXCEEDS 50% OF THE | | | IMPROVEMENT VALUE OF THE STRUCTURE, THEREFORE A | | | SEPERATE LANDSCAPE PERMIT IS REQUIRED AND MUST BE | | | SUBMITTED FOR ZONING APPROVAL TO MOVE FORWARD | | | | | | SEC 94-441 (B) | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|