| 2022-08-17 15:10:46 | RESIDENTIAL (R3) BUILDING REVIEW COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #22071395 3115 WASHINGTON RD |
| | |
| | 1- AXONOMETRIC DRAWING ON SHEET 1 OF 2 OF CANOPY |
| | DRAWINGS SHOWS A CANOPY ATTACHED ON TWO SIDES OF |
| | EXISTING HOUSE. SITE PLAN (SURVEY)SUBMITTED SHOWS |
| | PROPOSED CANOPY TO BE ATTACHED TO ONLY ONE SIDE OF THE |
| | REAR OF THE HOUSE. ENGINEER OF RECORD TO REVISE AS |
| | REQUIRED TO MATCH SITE SPECIFIC INSTALLATION. |
| | SEC. 107.2.1 CITY AMENDMENTS. SEC. R301.2.1 |
| | FBC-RESIDENTIAL. |
| | |
| | 2- AXONOMETRIC DRAWING ON SHEET 1 OF 2 OF CANOPY |
| | DRAWINGS SHOWS A CANOPY SUPPORTED ON ONLY TWO COLUMNS. |
| | ONE ON ONE CORNER AND ANOTHER ONE IN THE MIDDLE OF THE |
| | CANOPY. SITE PLAN (SURVEY)SUBMITTED SHOWS PROPOSED |
| | CANOPY TO BE ATTACHED TO ONLY ONE SIDE OF THE REAR OF |
| | THE HOUSE. ENGINEER OF RECORD TO REVISE AS REQUIRED TO |
| | MATCH SITE SPECIFIC INSTALLATION. COORDINATE WITH ITEM |
| | #1 ABOVE. SEC. 107.2.1 CITY AMENDMENTS. SEC. R301.2.1 |
| | FBC-RESIDENTIAL. |
| | |
| | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND |
| | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE |
| | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |