Plan Review Details - Permit 22071340
Plan Review Stops For Permit 22071340
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2023-07-25 Cont ID  
Sent By pvalenti Date 2023-07-24 Time 16:51 Rev Time 0.00
Received By pvalenti Date 2023-07-24 Time 16:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2023-07-17 Cont ID  
Sent By pvalenti Date 2023-07-17 Time 08:47 Rev Time 0.00
Received By pvalenti Date 2023-07-17 Time 07:25 Sent To  
Notes
2023-07-17 08:52:05PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING 3RD REVIEW DENIED:
  
  
  
 3.) FBC B 107.2.1/FBC B 107.3.4.1, PROVIDE PRODUCT
 APPROVALS FOR WINDOWS, DOORS, & ROOFING MATERIALS OR
 PROVIDE A LIST ON PLANS OF DEFERRED SUBMITTALS.
 (THE DEFERRED SUBMITTAL LIST IS NOT ON PLAN SHEETA-1 AS
 STATED ON RESPONSE SHEET. PLEASE PROVIDE.)
  
  
 NOTE: IT IS HELPFUL TO PROVIDE A RESPONSE SHEET FOR
 EACH OF THE PENDING ITEMS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-03-29 Cont ID  
Sent By pvalenti Date 2023-03-29 Time 11:13 Rev Time 0.00
Received By pvalenti Date 2023-03-24 Time 15:13 Sent To  
Notes
2023-03-29 11:14:07PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 1.) FBC B 107.2.1, ON PLAN SHEET S-3, DETAIL 1 IS
 INDICATED ON EAST SIDE OF ROOF. THIS DETAIL NOW
 INDICATES WOOD TRUSS RUNNING PARALLEL WITH WALL AND NO
 CONNECTION POINT DETAILS TO WALL. AT THE LOCATION
 INDICATED (EAST WALL) IT APPEARS THAT THE WOOD TRUSS
 ARE RUNNING PERPINDICULAR WITH WALL AND CONNECTION
 DETAILS ARE MISSING. PLEASE PROVIDE CONNECTION DETAILS
 FOR ALL TRUSS CONNECTIONS INCLUDING THE UPLIFT
 REQUIREMENTS AND CAPACITIES AT ALL CONNECTION
 LOCATIONS.
  
 2.) FBC B 107.2.1, ON PLAN SHEET A-7, DETAIL 1 IS
 INDICATED FOR STAIR CANTILEVERED CONNECTION. PLEASE
 PROVIDE MORE DETAILS AND SPECIFICATIONS AS TO WALL
 CONNECTIONS.
  
 3.) FBC B 107.2.1/FBC B 107.3.4.1, PROVIDE PRODUCT
 APPROVALS FOR WINDOWS,DOORS, & ROOFING MATERIALS OR
 PROVIDE A LIST ON PLANS OF DEFERRED SUBMITTALS.
  
 4.) FBC R 401.3, INDICATE ON SITE PLAN/SURVEY THE
 ELEVATION & DRAINAGE INDICATORS SHOWING DIRECTION OF
 SURFACE WATER TO STORM WATER INLETS.
  
 NOTE: IT IS HELPFUL TO PROVIDE A RESPONSE SHEET FOR
 EACH OF THE PENDING ITEMS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-10-21 Cont ID  
Sent By pvalenti Date 2022-10-21 Time 11:02 Rev Time 0.00
Received By pvalenti Date 2022-10-21 Time 07:30 Sent To  
Notes
2022-10-21 11:28:48PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 1.) FBC B 107.2.1, ON PLAN SHEET S-3, DETAIL 1 IS
 INDICATED ON EAST SIDE OF ROOF. THIS DETAIL INDICATES
 HOLLOW CORE PANELS RUNNING PARALLEL WITH WALL AND NO
 BEARING/CONNECTION POINT TO WALL. AT THE LOCATION
 INDICATED (EAST WALL) IT APPEARS THAT THE HOLLOW CORE
 PANELS ARE RUNNING PERPINDICULAR WITH WALL AND
 BEARING/CONNECTION DETAIL IS MISSING. PLEASE PROVIDE
 DETAIL OR CLARIFICATION.
  
 2.) FBC B 107.2.1, ON PLAN SHEET A-7, DETAIL 1 IS
 INDICATED FOR STAIR CANTILEVERED CONNECTION. PLEASE
 PROVIDE MORE DETAILS AND SPECIFICATIONS AS TO WALL
 CONNECTIONS.
  
 3.) FBC B 107.2.1/FBC B 107.3.4.1, PROVIDE PRODUCT
 APPROVALS FOR WINDOWS,DOORS, & ROOFING MATERIALS OR
 PROVIDE A LIST ON PLANS OF DEFERRED SUBMITTALS.
  
 4.) FBC R 401.3, INDICATE ON SITE PLAN/SURVEY THE
 ELEVATION & DRAINAGE INDICATORS SHOWING DIRECTION OF
 SURFACE WATER TO STORM WATER INLETS.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2023-07-10 Cont ID  
Sent By mpeterso Date 2023-07-10 Time 08:27 Rev Time 0.00
Received By mpeterso Date 2023-07-10 Time 08:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2023-03-27 Cont ID  
Sent By mpeterso Date 2023-03-27 Time 08:30 Rev Time 0.00
Received By mpeterso Date 2023-03-27 Time 07:55 Sent To  
Notes
2023-03-27 08:59:36ELECTRIC REVIEW FAILED
  
 1) ELECTRIC LOAD CALCULATION IS STILL INCORRECT. ONLY
 TWO AC LOADS ARE LISTED AND THREE ARE PRESENT. THERE IS
 NO RANGE LOAD LISTED. NO WATER HEATERS ARE LISTED.
 THERE ARE CONFLICTS ON DRAWINGS INDICATING A 66 GALLON
 ON ONE SHEET AND TWO TANKLESS ON ANOTHER. PLEASE
 PROVIDE A CORRECTED CALCULATIO WITH ALL LOADS LISTED.
 IN MY EXPERIENCE THE OPTIONAL CALCULATION IS EASIER TO
 PROCESS AND ALLOWS A SMALLER DEMAND.
 2) THERE IS STILL NO SMOKE/CARBON ALARM SHOWN ON THE
 FIRST FLOOR AS REQUIRED. PLEASE DETAIL THE ALARM AS
 REQUIRED
 3) PLEASE PROVIDE AN ACCURATE PANEL SCHEDULE LISTING
 ALL LOADS. IE THREE AIR CONDITIONING UNITS, TWO
 TANKLESS WATER HEATERS OR THE 66 GALLON.
 4) IF TANKLESS WATER HEATERS ARE TO BE USED, PLEASE
 PROVIDE SPECIFICATIONS
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-10-12 Cont ID  
Sent By mpeterso Date 2022-10-12 Time 14:51 Rev Time 0.00
Received By mpeterso Date 2022-10-12 Time 14:51 Sent To  
Notes
2022-10-12 15:14:13ELECTRIC REVIEW FAILED
 1) PLEASE PROVIDE AN ELECTRIC RISER. NEC 215.5
 2) IT APPEARS THE LOAD CACULATION PROVIDED IS INCORRECT
 THERE IS NO COOK TOP OR OVEN LISTED. THE WATER HEATER
 IS LISTED AS 900VA ON PANEL SCHEDULE AND 4500 ON LOAD
 CALCULATION. CAR CHARGER IS LISTED AS 9600 VA ON PANEL
 SCHEDULE AND 23000 VA ON LOAD CALCULATION. THERE
 APPEARS TO BE 3 AIRCONDITIONING SYSTEMS AND ONLY 2 ARE
 LISTED IN THE PANEL SCHEDULES AND LOAD CALCULATION
 PLEASE PROVIDE ACCURATE LOAD CALCULATIONS AND PANEL
 SCHEDULES. NEC 215.5 AND NEC 220
 3) PLEASE DETAIL THE REQUIRED CARBON/SMOKE ALARKS AT
 THE 1ST LEVEL AND SECOND LEVEL AS REQUIRED PER FBC R
 314 AND 315. CARBON SMOKE ALARMS AT EACH LEVEL AND
 WITHIN 10" OF SLEEPING AREAS
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2023-07-10 Cont ID  
Sent By rwbrown Date 2023-07-10 Time 13:32 Rev Time 0.00
Received By rwbrown Date 2023-07-10 Time 13:32 Sent To  
Notes
2023-07-10 13:33:08PLANS UPLOADED BY RWB AND REVIEW COMPLETED.

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-07-10 Cont ID  
Sent By rwbrown Date 2023-06-30 Time 07:39 Rev Time 0.00
Received By rwbrown Date 2023-06-30 Time 07:39 Sent To  
Notes
2023-06-30 07:41:411ST GAS REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2017 WPB AMEND 107.3.5.3 (13) - YOU'VE SUBMITTED A
 SPEC SHEET FOR A TANKLESS GAS WATER HEATER BUT HAVE NO
 GAS DETAILS IN THE PLANS. PLEASE ADD GAS TO THE PLANS.
 INCLUDE AN ISOMETRIC WITH PIPE LENGTHS, MATERIALS AND
 SIZING METHOD. ALSO INCLUDE A FLOOR PLAN SHOWING THE
 LOCATION OF THE GAS FIXTURES AND PIPE ROUTING. SHOW
 DETAILS FOR SEPARATION OF EXHAUSTS TO OPENINGS AS WELL
 AS COMBUSTION AIR DETAILS AND APPLIANCE VENTING.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By aoliver Date 2023-07-25 Time 13:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-07-17 Cont ID  
Sent By pvalenti Date 2023-07-17 Time 08:52 Rev Time 0.00
Received By pvalenti Date 2023-06-28 Time 10:49 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-29 Cont ID  
Sent By pvalenti Date 2023-03-29 Time 11:26 Rev Time 0.00
Received By pvalenti Date 2023-03-13 Time 08:03 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-10-21 Cont ID  
Sent By pvalenti Date 2022-10-21 Time 13:45 Rev Time 0.00
Received By pvalenti Date 2022-09-19 Time 05:47 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By lmarchan Date 2023-07-24 Time 16:58 Sent To  
Notes
2023-07-24 16:58:377/24/23 EMAILED IMPACT OFFICE TO REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-10-21 Cont ID  
Sent By pvalenti Date 2022-10-21 Time 13:43 Rev Time 0.00
Received By pvalenti Date 2022-10-21 Time 13:43 Sent To  
Notes
2022-10-21 13:44:43IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-09-21 Cont ID  
Sent By medwards Date 2022-09-21 Time 13:04 Rev Time 0.00
Received By medwards Date 2022-09-21 Time 13:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2023-06-30 Cont ID  
Sent By rwbrown Date 2023-06-30 Time 07:42 Rev Time 0.00
Received By rwbrown Date 2023-06-30 Time 07:42 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-03-14 Cont ID  
Sent By rwbrown Date 2023-03-14 Time 06:57 Rev Time 0.00
Received By rwbrown Date 2023-03-14 Time 06:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-09-27 Cont ID  
Sent By rwbrown Date 2022-09-27 Time 08:18 Rev Time 0.00
Received By rwbrown Date 2022-09-27 Time 08:14 Sent To  
Notes
2022-09-27 08:22:051ST PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
  
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FRC P3108.1 - THE WATER CLOSET ON THE 1ST FLOOR
 IS NOT VENTED TO CODE. PLEASE RECONFIGURE AND RESUBMIT.
 (CONNECT LAV TO WATER CLOSET FIXTURE DRAIN INSTEAD OF
 HORIZONTAL BRANCH)
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2023-07-24 Cont ID  
Sent By pvalenti Date 2023-07-24 Time 16:51 Rev Time 0.00
Received By pvalenti Date 2023-07-24 Time 16:51 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2023-07-17 Cont ID  
Sent By pvalenti Date 2023-07-17 Time 07:56 Rev Time 0.00
Received By pvalenti Date 2023-07-17 Time 07:25 Sent To  
Notes
2023-07-17 07:57:59PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 3RD ROOFING REVIEW DENIED:
  
 FBC B 107.2.1, PROVIDE ENGINEER'S LETTER ADDRESSING NOA
 # 20-0723.29 (LIMITATIONS #7) FOR ROOF ZONES 1, 2, & 3
 WINDLOAD PRESSURES, ANCHOR SPACING, AND ATTACHMENT OF
 TAPERED INSULATION AS PER FBC R 906, BASE
 SHEET/MODIFIED BITUMEN AS PER FBC R 905.11.
  
 NOTE: A ROOFING SUB-PERMIT IS REQUIRED PRIOR TO ROOF
 WORK.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2023-03-29 Cont ID  
Sent By pvalenti Date 2023-03-29 Time 10:42 Rev Time 0.00
Received By pvalenti Date 2023-03-24 Time 15:13 Sent To  
Notes
2023-03-29 10:43:32PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 2ND ROOFING REVIEW DENIED:
  
 FBC B 107.2.1, PROVIDE METHOD OF ROOFING INCLUDING
 MATERIALS/PRODUCT APPROVALS AND ATTACHMENT OF TAPERED
 INSULATION AS PER FBC R 906, BASE SHEET/MODIFIED
 BITUMEN AS PER FBC R 905.11, AND WINDLOAD PRESSURES AT
 ALL ROOF ZONES AS PER FBC R 301.
  
 NOTE: A ROOFING SUB-PERMIT IS REQUIRED PRIOR TO ROOF
 WORK.
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-10-21 Cont ID  
Sent By pvalenti Date 2022-10-21 Time 13:10 Rev Time 0.00
Received By pvalenti Date 2022-10-21 Time 13:10 Sent To  
Notes
2022-10-21 13:39:31PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 ROOFING REVIEW DENIED:
  
 FBC B 107.2.1, PROVIDE METHOD OF ROOFING INCLUDING
 MATERIALS/PRODUCT APPROVALS AND ATTACHMENT OF TAPERED
 INSULATION AS PER FBC R 906, BASE SHEET/MODIFIED
 BITUMEN AS PER FBC R 905.11, AND WINDLOAD PRESSURES AT
 ALL ROOF ZONES AS PER FBC R 301.
  
 NOTE: A ROOFING SUB-PERMIT IS REQUIRED PRIOR TO ROOF
 WORK.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-07-10 Cont ID  
Sent By mpeterso Date 2023-07-10 Time 08:27 Rev Time 0.00
Received By mpeterso Date 2023-07-10 Time 08:27 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-03-29 Cont ID  
Sent By pvalenti Date 2023-03-29 Time 11:26 Rev Time 0.00
Received By pvalenti Date 2023-03-29 Time 11:26 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-10-12 Cont ID  
Sent By mpeterso Date 2022-10-12 Time 15:17 Rev Time 0.00
Received By mpeterso Date 2022-10-12 Time 15:17 Sent To  
Notes
2022-10-12 15:19:45SIGNATURE REVIEW FAILED
  
 IT APPEARS SHEETS T-1 AND S-2 DO NOT HAVE THE REQUIRED
 DIGITAL SIGNATURE AND SEAL. IN ADDITION, SHEET S-1
 DETAILS AN INVALID SIGNATURE USING BLUEBEAM SOFTWARE.
 PLEASE CORRECT AS OUTLINED BELOW
  
 FS471/FS481 DOCUMENTS PREPARED BY ARCHITECT/ENGINEER OF
 RECORD AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 DIGITALLY SEALED AND SIGNED.
  
 PLEASE SUBMIT DIGITALLY SEALED AND SIGNED PLANS
 FOLLOWING PROJECTDOX INSTRUCTIONS
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  
2022-09-21 13:04:55MECHANICAL DIGITAL SIGNATURES APPROVED ME

Review Stop Z ZONING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2023-07-11 Cont ID  
Sent By vbroglia Date 2023-07-11 Time 14:03 Rev Time 0.00
Received By vbroglia Date 2023-07-11 Time 14:03 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-10-03 Cont ID  
Sent By vbroglia Date 2022-10-03 Time 14:51 Rev Time 0.00
Received By vbroglia Date 2022-10-03 Time 14:51 Sent To  
Notes
***NONE***