Plan Review Details - Permit 22071316
Plan Review Stops For Permit 22071316
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2022-11-01 Cont ID  
Sent By rmcdouga Date 2022-11-01 Time 15:59 Rev Time 0.00
Received By rmcdouga Date 2022-11-01 Time 15:59 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-11-01 Cont ID  
Sent By rmcdouga Date 2022-11-01 Time 16:17 Rev Time 0.00
Received By rmcdouga Date 2022-11-01 Time 16:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-09-06 Cont ID  
Sent By rmcdouga Date 2022-09-06 Time 10:44 Rev Time 0.00
Received By rmcdouga Date 2022-09-06 Time 10:38 Sent To  
Notes
2022-09-06 10:44:30PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT A COPY OF THE ACTUAL TEST REPORTS FOR THE
 SOUND INSULATION INCLUDING FLAME SPREAD AND SMOKE
 DEVELOPED FOR THE APPLICABLE CONSTRUCTION CONDITIONS.
 THE TEST REPORTS FOR THE PROPOSED UNDERLAYMENT SHALL BE
 BASED ON THE CONCRETE SLAB THICKNESS AND ONY OTHER
 EXISTING SITE CONDITIONS.
 TEST REPORTS MAY BE BASED ON THE FOLLOWING ASTM'S:
 E-84, E-90 & E-492.
 - FBC 603.1 FLAME SPREAD - ASTM E 84-09
  
 - FBC 1207.2 AIR-BORNE SOUND. ASTM E 90-04
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 - FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E 492-09
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-08-01 Cont ID  
Sent By cwalker Date 2022-08-01 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-11-01 Cont ID  
Sent By rmcdouga Date 2022-11-01 Time 16:17 Rev Time 0.00
Received By rmcdouga Date 2022-10-03 Time 06:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-09-06 Cont ID  
Sent By rmcdouga Date 2022-09-06 Time 10:44 Rev Time 0.00
Received By rmcdouga Date 2022-08-01 Time 05:22 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-10-06 Cont ID  
Sent By rwbrown Date 2022-10-06 Time 12:26 Rev Time 0.00
Received By rwbrown Date 2022-10-06 Time 12:26 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2022-09-06 Cont ID  
Sent By rmcdouga Date 2022-09-06 Time 10:41 Rev Time 0.00
Received By rmcdouga Date 2022-09-06 Time 10:38 Sent To  
Notes
***NONE***