| Plan Review Stops For Permit 22071298 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2022-08-11 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-08-11 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-08-11 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2022-08-11 09:24:28 | WORK MERGES SUITES 200, 201 AND A PORTION OF 202, SUITE | | | WILL BE KNOWN AS SUITE 200 AND SUITE 201 WILL BE | | | RETIRED |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-08-01 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-08-01 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2022-08-01 16:51:34 | PLANS INDICATE THAT 3 SUITES WILL BE MERGING 200, 201 | | | AND 202. A SINGLE ADDRESS SHOULD BE ASSIGNED TO THE NEW | | | MERGE SUITE. PLEASE CONTACT [email protected] OR | | | CALL 561-805-6659 TO DISCUSS ADDRESSING ISSUES. |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
P |
Date |
2022-09-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-09-07 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2022-08-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-08-22 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-08-22 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2022-08-22 11:14:47 | COMMERCIAL ASBESTOS | | | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON THE CONTRACTORS LETTERHEAD, STATING THAT | | | THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | | ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION | | | -RENOVATION.HTML | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-09-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-09-07 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-09-07 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2022-09-07 09:49:14 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 22071298 | | | ADD: 4047 OKEECHOBEE BLVD. # 200, 201 & 202 | | | CONT: PBB CONSTRUCTION, LLC | | | TEL: 561-767-7681 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: WED. SEPT. 07TH/2022 | | | ACTION: PASSED/ BUILDING PROVISO | | | | | | 1) BUILDING PROVISO: WELDED OR BOLTED CONNECTIONS. THIS | | | BUILDING CONTAINS EITHER BOLTED AND OR WELDED | | | CONNECTIONS. THE CONTRACTOR IS REQUIRED TO PROVIDE WELD | | | PROCEDURE SPECIFICATIONS & WELDER OPERATOR PERFORMANCE | | | QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED | | | STANDARDS AT TIME OF INSPECTION FOR FIELD WIELDING, ON | | | THE JOB-SITE WIELDING. THIRD PARTY CERTIFICATION WILL | | | BE REQUIRED. | | | THE OWNER MAY JUST HIRE A 3RD PARTY ENGINEERING FIRM TO | | | COMPLETE AND APPROVE THE FORMER INSPECTIONS. REPORTS | | | SUBMITTED TO BUILDING INSPECTOR AT TIME OF FRAMING | | | INSPECTION. | | | 2020 FBC-B 2204.1 WELDING | | | 1. WELD PROCEDURES SPECIFICATIONS | | | 2. QUALIFICATIONS OF WELDING PERSONAL | | | 2017 FBC-B 2204.2 BOLTING. | | | IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED, | | | PLEASE CONTACT THE ACTING CHIEF BUILDING INSPECTOR | | | RICHARD BRUNELLE AT 561-805-6670. | | | | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-08-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-08-22 |
Time |
17:18 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-08-22 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2022-08-22 17:18:55 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 22071298 | | | ADD: 4047 OKEECHOBEE BLVD. # 200, 201 & 202 | | | CONT: PBB CONSTRUCTION, LLC | | | TEL: 561-767-7681 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. AUGUST 22/2022 | | | ACTION: DENIED | | | | | | 1) SHEET ALS1.1: | | | 1A) UNDER THE HEADING BUILDING AREA THE ACTUAL BUILDING | | | AREA IS LISTED AS 3,870 SQ. FT. PLEASE REVIEW THE | | | EXISTING AND PROPOSED SITE PLAN THE ACTUAL BUILDING | | | AREA IS 29,271 SQ. FT. THE TENANT AREA IS 3,870 SQ. FT. | | | TYPO PLEASE CORRECT. 107.2.1 ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | 1B) NOTES SECTION 508.3 NONSEPARATED OCCUPANCIES. WORST | | | CASE SCENARIO OCCUPANCY WHICH IS S-2 STATED IN PLANS. | | | THE LS1.1 AND A1.1.1 FLOOR PLAN ONLY SHOW THE AUTO | | | DEALERSHIP SHOWROOM A BUSINESS OCCUPANCY, WHERE IS THE | | | S-2 PARKING GARAGE, OPEN OR ENCLOSED? | | | | | | 1C) TABLE 1004.1.2 FLOOR AREA ALLOWABLE PER OCCUPANT. | | | PLEASE REFER TO THE 2020 FBC-BUILDING TO UPDATED TABLE | | | 1004.5. | | | | | | 1D) 2020 FBC-BUILDING TO UPDATED TABLE 1004.5. THE | | | OCCUPANT LOAD FACTOR IS NO LONGER 100 BUT 150 SQ. FT./ | | | OCCUPANT. PLEASE UPDATE PLANS. | | | | | | 1E) THE OCCUPANT LOAD COUNT IS NOT GIVEN CORRECTLY, | | | PLUMBING FIXTURE LIST 39 OCCUPANTS, 3870/ 150= 26 | | | OCCUPANTS. 2020 FBC-BUILDING CODE. | | | | | | 2) SHEET S-4: | | | 2A) SECTION 1 & SECTION 3 BOTH SHOW NEW ? X 10 ?X10? | | | BASE PLATE, VERTICAL HSS 4X4X1/4 TUBING, AND W12X19 | | | STEEL BEAM, THE PLANS DO NOT PROVIDE TYPE OF WELDS NOR | | | SIZE OF WELDS? | | | 2020 FBC-BUILDING CODE 2204.1. | | | 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION 107.2.1. CONSTRUCTION | | | DOCUMENTS SHALL BE SUFFICIENT CLARITY TO INDICATE THE | | | LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED AND | | | SHOW IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS | | | OF THIS CODE AND RELEVANT LAWS, ORDINANCES, RULES AND | | | REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 2B) WELDED OR BOLTED CONNECTIONS. THIS BUILDING | | | CONTAINS EITHER BOLTED AND OR WELDED CONNECTIONS. THE | | | CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE | | | SPECIFICATIONS & WELDER OPERATOR PERFORMANCE | | | QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED | | | STANDARDS AT TIME OF INSPECTION FOR FIELD WIELDING, ON | | | THE JOB-SITE WIELDING. THIRD PARTY CERTIFICATION WILL | | | BE REQUIRED. | | | THE OWNER MAY JUST HIRE A 3RD PARTY ENGINEERING FIRM TO | | | COMPLETE AND APPROVE THE FORMER INSPECTIONS. REPORTS | | | SUBMITTED TO BUILDING INSPECTOR AT TIME OF FRAMING | | | INSPECTION. | | | 2020 FBC-B 2204.1 WELDING | | | 1. WELD PROCEDURES SPECIFICATIONS | | | 2. QUALIFICATIONS OF WELDING PERSONAL | | | 2017 FBC-B 2204.2 BOLTING. | | | IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED, | | | PLEASE CONTACT THE ACTING CHIEF BUILDING INSPECTOR | | | RICHARD BRUNELLE AT 561-805-6670. | | | | | | 3) ROOFING PRODUCT APPROVAL FL. 2948-R15 WAS SUBMITTED. | | | PAGE 2 OF 49 TABLE 2A CIRCLED, STEEL OR CONCRETE | | | DECKING, NEW, REROOF (TEAR-OFF) OR RECOVER TYPE B-1 | | | MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP | | | INSULATION, BONDED COVER SHEET PAGES THESE SYSTEMS ARE | | | ON 10-14, APPENDIX PAGE 1 OF 49. | | | SHEET 4 OF 49 HEADING MEMBRANE/ ADHESIVE COMBINATION, | | | MATERIAL ARE HIGHLIGHTED. BUT PAGE 9 OF 49 FOR WOOD | | | DECKS WAS CIRCLED AND HIGHLIGHTED, - 60.0 VASD. THE | | | WOOD SYSTEM DOES ALLOW FOR INCREASED FASTENING IN ROOF | | | ZONES 2 & 3 AS PER RAS 117. MISSING PAGES 10-14 FOR | | | STEEL DECKING AND ANCHOR FASTENING, WE DO NOT KNOW | | | ALLOWABLE PRESSURES, MISSING PAGES AND IF INCREASE | | | FASTENING IS ALLOWED. | | | | | | 4) NOA 21-1216.10 TRULITE 3100 WINDOW WALL SYSTEM LMI. | | | IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY IN THE | | | PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF | | | RECORD AND BEFORE SUBMISSION TO THE BUILDING | | | DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE | | | IDENTIFY THE OPENING WIDTH & HEIGHT, SILL HEIGTH, TYPE | | | OF GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED OR | | | REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND | | | ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B | | | 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE | | | INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER?S | | | INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE | | | PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED | | | BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS. | | | | | | 5) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ SEMI-RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-09-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-09-14 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-09-14 |
Time |
09:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-08-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-08-12 |
Time |
07:22 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-08-12 |
Time |
06:41 |
Sent To |
|
|
| Notes |
| 2022-08-12 07:24:10 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PLEASE PROVIDE A RISER DIAGRAM AND LOAD CALCULATION FOR | | | PANEL INVOLVED. 215.5 |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2022-08-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-08-12 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-08-12 |
Time |
07:24 |
Sent To |
|
|
| Notes |
| 2022-08-12 07:25:15 | VOICE AND DATA AS PER PLANS JLEAHY |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-08-31 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-08-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
bdolan |
Date |
2022-08-31 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2022-08-31 12:58:16 | THE FOLLOWING COMMENTS WERE SUBMITTED BY LT. BRIAN | | | DOLAN, DIVISION OF FIRE PREVENTION, WEST PALM BEACH | | | FIRE RESCUE. | | | | | | AS PER PLAN SET, ANY REMOVAL AND/OR CONSTRUCTION OF THE | | | CEILING/WALL AREAS MAY REQUIRE AN EVALUATION OR | | | MODIFICATION OF THE FIRE SPRINKLER AND FIRE ALARM | | | SYSTEMS (IF PRESENT) FOR CODE COVERAGE AND COMPLIANCE | | | BY CERTIFIED CONTRACTORS. | | | | | | ANY AND ALL WORK ON THE FIRE ALARM SYSTEM SHALL BE DONE | | | BY A FIRE ALARM CONTRACTOR. A SEPARATE SHOP DRAWING | | | COMPLIANT WITH NFPA 72 IS REQUIRED TO BE SUBMITTED, | | | REVIEWED AND APPROVED BY THE FIRE PREVENTION BUREAU | | | PRIOR TO ANY INSTALLATION. | | | | | | ALL WORK ON THE FIRE SPRINKLER SYSTEM IS REQUIRED TO BE | | | COMPLETED BY A CERTIFIED FIRE SPRINKLER CONTRACTOR AND | | | SHALL COMPLY WITH NFPA 13. SEPARATE SHOP DRAWINGS, ARE | | | REQUIRED TO BE SUBMITTED, REVIEWED AND APPROVED BY THE | | | FIRE PREVENTION BUREAU PRIOR TO ANY WORK ON THE SYSTEM. | | | | | | | | | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | | | | LT. BRIAN DOLAN | | | DIVISION OF FIRE PREVENTION | | | 561-804-4752 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-08-11 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-08-11 |
Time |
|
Rev Time |
0.00 |
| Received By |
bdolan |
Date |
2022-08-01 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2022-08-11 13:47:28 | THE FOLLOWING COMMENTS WERE SUBMITTED BY LT. BRIAN | | | DOLAN, DIVISION OF FIRE PREVENTION, WEST PALM BEACH | | | FIRE RESCUE. | | | | | | AS PER PLAN SET, ANY REMOVAL AND/OR CONSTRUCTION OF THE | | | CEILING/WALL AREAS MAY REQUIRE AN EVALUATION OR | | | MODIFICATION OF THE FIRE SPRINKLER AND FIRE ALARM | | | SYSTEMS (IF PRESENT) FOR CODE COVERAGE AND COMPLIANCE | | | BY CERTIFIED CONTRACTORS. | | | | | | ANY AND ALL WORK ON THE FIRE ALARM SYSTEM SHALL BE DONE | | | BY A FIRE ALARM CONTRACTOR. A SEPARATE SHOP DRAWING | | | COMPLIANT WITH NFPA 72 IS REQUIRED TO BE SUBMITTED, | | | REVIEWED AND APPROVED BY THE FIRE PREVENTION BUREAU | | | PRIOR TO ANY INSTALLATION. | | | | | | ALL WORK ON THE FIRE SPRINKLER SYSTEM IS REQUIRED TO BE | | | COMPLETED BY A CERTIFIED FIRE SPRINKLER CONTRACTOR AND | | | SHALL COMPLY WITH NFPA 13. SEPARATE SHOP DRAWINGS, ARE | | | REQUIRED TO BE SUBMITTED, REVIEWED AND APPROVED BY THE | | | FIRE PREVENTION BUREAU PRIOR TO ANY WORK ON THE SYSTEM. | | | | | | | | | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | | | | LT. BRIAN DOLAN | | | DIVISION OF FIRE PREVENTION | | | 561-804-4752 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-10-05 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-10-05 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-10-05 |
Time |
09:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-10-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-10-03 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-09-30 |
Time |
10:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-09-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-09-24 |
Time |
07:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-08-30 |
Time |
15:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-08-24 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-08-24 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-07-29 |
Time |
07:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2022-10-03 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-10-03 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-09-21 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2022-10-03 09:19:25 | RECEIPT MU-2022-043652-0000 - $1,310.85 PAID AO | | 2022-09-21 09:38:10 | 9/21/22 EMAILED IMPACT OFFICE TO REVIEW PER DBATTLES | | | LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-08-19 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-08-19 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-08-19 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2022-08-19 15:45:52 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2022-08-12 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-12 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-12 |
Time |
09:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-08-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-31 |
Time |
07:29 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-31 |
Time |
07:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-01 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-01 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2022-08-01 15:08:40 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 22071298 | | | 8/1/2022 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET ALS.1.1: DRINKING FOUNTAINS AND A SERVICE SINK | | | ARE REQUIRED FIXTURES FOR B OCCUPANCIES BASED ON TABLE | | | 403.1 FBC P. THE FOOT NOTE BELOW THE PLUMBING FIXTURE | | | CALCULATION TO PROVIDE BOTTLED WATER IS NOT IN | | | COMPLIANCE WITH TABLE 403.1 & SEC. 410.4 FBC P, AND IS | | | ONLY APPLICABLE FOR RESTAURANTS. PLEASE REVISE THE PLAN | | | TO SHOW THE FIXTURE LOCATIONS AND PLUMBING PIPING | | | DETAILS. PLEASE NOTE THAT HOT WATER AT MINIMUM | | | TEMPERATURE OF 110 DEGREES F SHALL BE DELIVERED FROM | | | THE MOP SINK, AND A MEANS OF LIMITING THE HOT WATER | | | TEMPERATURE IS REQUIRED- SECS. 607.1 & 607.1.1 FBC P. | | | | | | 2) A.9.0.2: REFER TO SECS 306, 307, AND 602 FBC ACC AND | | | PROVIDE DRINKING FOUNTAIN INSTALLATION DETAILS AND | | | ELEVATION VIEWS SHOWING KNEE AND TOE CLEARANCES, SPOUT | | | HEIGHTS, AND SPOUT LOCATIONS. SHOW THE REQUIRED 30 X 48 | | | IN. CLEAR FLOOR SPACE FOR A FORWARD WHEELCHAIR APPROACH | | | TO THE FOUNTAIN- SEC. 602.2 FBC ACC, AND SHOW HOW THE | | | LOCATIONS OF THE FOUNTAINS WILL BE IN COMPLIANCE WITH | | | SEC. 307.2 PROTRUSION LIMITS. | | | | | | 3) A.9.0.2 DETAIL 8: THE DOOR SHALL NOT SWING INTO THE | | | CLEAR FLOOR SPACE OF THE LAVATORY UNLESS MEETING | | | EXCEPTION 2 UNDER SEC. 602.3.2 FBC ACC. THE DETAIL | | | SHOWS THE ARC OF THE DOOR OVERLAPPING THE LAVATORY | | | CLEAR FLOOR SPACE AND THE 30X48-INCH CLEAR FLOOR | | | MANEUVERING SPACE. | | | | | | 4) A.9.02 DETAILS 2, 3, 6, & 7: PLEASE SHOW THE GRAB | | | HEIGHT MEASUREMENT FROM THE FINISHED FLOORS TO THE TOPS | | | OF THE GRAB BARS- SEC. 609.4 FBC ACC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2022-11-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-11-01 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-11-01 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2022-11-01 08:44:30 | THE 2ND REVIEW THEY SUBMITTED A ROOFING PRODUCT | | | APPROVAL FOR JOHN MANVILLE FLORIDA APPROVAL # | | | FL2948-R16 APPENDIX 1, PAGE 17 OF 49 SYSTEM S-67 GOOD | | | FOR -135.0 PSF |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2022-10-06 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-10-06 |
Time |
05:52 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-10-06 |
Time |
05:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2022-10-05 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-10-05 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-10-05 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2022-10-05 16:47:11 | SIGNATURE REVIEW DENIED: | | | | | | THE PLAN SHEETS (S-1, S-2, & S-3) NEED TO BE 3RD PARTY | | | VERIFIABLE DIGITAL SIGNATURES AS PER NOTES BELOW: | | | | | | FS 471/FS 481 DOCUMENTS PREPARED BY AN | | | ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE | | | TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A | | | SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL. | | | UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY | | | VERIFIED) PLAN: | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | FEEL FREE TO CONTACT ME AT 561 805 6673. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-10-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-10-03 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-10-03 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2022-10-03 15:39:56 | | | | SIGNATURE REVIEW DENIED: | | | | | | THE SUBMITTED PLAN SHEETS, Z-2, Z-3, S-1, S-2, & S-3 | | | NEED TO HAVE DIGITAL SIGNATURES AS PER NOTES BELOW: | | | | | | SIGNATURE REVIEW DENIED: | | | | | | FS 471/FS 481 DOCUMENTS PREPARED BY AN | | | ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE | | | TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A | | | SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL. | | | UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY | | | VERIFIED) PLAN: | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | FEEL FREE TO CONTACT ME AT 561 805 6673 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-09-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-09-14 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-09-14 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-08-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-08-22 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-08-19 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2022-08-12 09:36:08 | MECHANICAL DIGITAL SIGNATURES APPROVED ME | | 2022-08-12 07:27:08 | ELECTRICAL PAGES SIGNATURES ARE APPROVED JLEAHY |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-09-30 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-09-30 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-09-30 |
Time |
14:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2022-09-22 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-09-22 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-09-22 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2022-09-22 16:21:29 | 09/22/22 FAILED- THIS PROJECT IS CURRENTLY IN THE ISPR | | | PROCESS TO OBTAIN SITE PLAN APPROVAL. ONCE SITE PLAN | | | APPROVAL IS OBTAINED, PLEASE UPLOAD THE APPROVED PLANS | | | TO THIS PERMIT | | | | | | ALEXANDER FOWLKES | | | 5618221431 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-08-24 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-08-24 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-08-24 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2022-08-24 09:35:53 | 08/24/22 FAILED- THIS PROJECT IS CURRENTLY IN THE ISPR | | | PROCESS TO OBTAIN SITE PLAN APPROVAL. SEE MY COMMENTS | | | BELOW FROM THE AUGUST 11TH PPRC DATE TO BE ADDRESSED | | | | | | 1. NEED TO PROVIDE ALL EXISTING AND PROPOSED PARKING | | | MEASUREMENTS (LENGTH/WIDTH) | | | 2. THE SHAPES OF THE PROPOSED LANDSCAPE AREA SEEM ODD. | | | 2A. WHY IS THERE SUCH A SMALL STRIP EXTENDING WEST? IT | | | LOOKS LIKE YOU?VE INCLUDED THE CURB AS A PART OF THE | | | LANDSCAPE AREA | | | 2B. WHY IS THERE A PORTION ON THE RIGHT SIDE OF THE | | | PROPOSED LANDSCAPED AREA THAT?S NOT INCLUDED? | | | 3. STREET VIEW IMAGES SHOW WHEEL STOPS ON THE WESTERN | | | PARKING SPACES SHOWN ON THE ENLARGED SITE PLAN. TO MAKE | | | UP FOR ADDITIONAL LANDSCAPE AREA, STAFF WOULD LIKE TO | | | SEE THESE REMOVED AND THE OVERHANG REPLACED WITH 2 FT | | | OF LANDSCAPED AREA. | | | 4. THE NEW LANDSCAPE ISLANDS NEED TO BE AT LEAST 8 FT | | | WIDE, WITH AN ADDITIONAL 6 INCHES OF CURB ON EITHER | | | SIDE. THE NEW LANDSCAPE ISLAND TO THE SOUTH OF THE | | | HANDOVER BAY NEEDS TO BE WIDENED TO MEET THIS | | | REQUIREMENT. | | | 5. ADDITIONAL PARKING SPACES MAY NEED TO BE ALTERED TO | | | MAKE SPACE FOR THIS. | | | 6. CONFIRM THAT ALL LANDSCAPE ISLANDS ARE THE SAME | | | LENGTH OF THE PARKING SPACES | | | 7. PROVIDE AN AUTOTURN ANALYSIS SHOWING CARS CAN STILL | | | TURN AROUND WITHOUT THE TURNAROUND SPACE. | | | 8. IT IS STAFFS UNDERSTANDING THAT THE LANDSCAPE FOR | | | THIS PROPERTY DOES NOT MATCH WHAT WAS APPROVED IN THE | | | PAST. THEREFORE, THE LANDSCAPING ON THIS PROPERTY NEEDS | | | TO MATCH THE LATEST APPROVED LANDSCAPE PLAN. CONTACT | | | STAFF FOR THIS DOCUMENT | | | 9. EXTERIOR CHANGES/SIGNAGE CAN BE ADDRESSED DURING | | | PERMITTING. | | | | | | ALEXANDER FOWLKES | | | [email protected] | | | 5618221431 |
|
|