| Plan Review Stops For Permit 22071259 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2022-12-16 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-12-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2022-10-17 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-10-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-09-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-08-09 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-08-09 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2022-12-21 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-12-21 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-12-15 |
Time |
09:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2022-12-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-12-02 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-11-29 |
Time |
16:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-11-03 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-11-03 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-19 |
Time |
07:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-10-18 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-14 |
Time |
08:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-09-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-07 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-01 |
Time |
14:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-08-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-18 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-08 |
Time |
07:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2022-12-21 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-12-21 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-12-21 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2022-12-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-12-02 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-12-02 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2022-12-02 14:22:19 | 5TH REVIEW FMC | | | PERMIT: 22071259 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) I AM STILL TRYING TO GET THE ANSWER TO COMMENT 1 OF | | | PREVIOUS REVIEW CYCLE. THE PERMIT NUMBER THAT WAS GIVEN | | | IN REFERENCE TO SHEET A8.0.1 IS THIS PERMIT NUMBER. | | | THERE ARE NO A SHEETS IN THIS SUBMITTAL AND THERE ARE A | | | LOT OF A SHEETS FOR THIS BUILDING, A LOT FOR EACH | | | PERMIT FOR THIS BUILDING AND BUILDOUTS. I AM ASKING FOR | | | YOU TO EITHER SUBMIT SHEET A8.0.1 AS A REFERENCE ONLY | | | SHEET OR TELL ME THE PERMIT NUMBER OF THE A.8.0.1 THAT | | | YOU ARE REFERENCING SO I CAN FIND IT MYSELF. | | | | | | 2) THE LETTER SUBMITTED FROM MR. ERIC CHAPA FROM | | | CAPTIVEAIRE ONLY STATES WHAT THE FMC STATES: SUCH ROOM | | | OR SPACES SHALL BE VENTILATED IN ACCORDANCE WITH THE | | | FAN MANUFACTURERS INSTALLATION INSTRUCTIONS. PLEASE | | | PROVIDE THIS INFORMATION FROM THE FAN MANUFACTURER. THE | | | REVISED DRAWING REFERENCES NOTE 10 (COOLING TUBE TO | | | MOTOR COMPARTMENT, BOTH SIDES) PLEASE PROVIDE A DETAIL | | | DRAWING OF THIS. PLEASE PROVIDE THE INSTALLATION | | | INSTRUCTIONS FOR THE GREASE DUCT IN-LINE FAN. FMC | | | 506.5.1.2 | | | | | | 3) PLEASE SUBMIT A REVISION FOR THE NEW PIZZA OVENS AND | | | THE DUCTWORK THAT IS NOW ON THE NEW SHEETS ADDED TO | | | THIS SUBMITTAL; MKH-502 AND MKH-503, INCLUDE THE ADDED | | | VALUE TO THIS REVISION. | | | | | | 4) PROVIDE A DESIGN FOR THE PIZZA OVENS DUCTWORK. IS | | | THE DUCTWORK FOR THESE PIZZA OVEN TO BE FIRE WRAPPED? | | | FBC 107.3.5 | | | | | | 5) PROVIDE SPECS FOR THE PIZZA OVENS THAT ARE SHOWN ON | | | THE NEW SHEETS MKH-502 AND MKH-503 ALSO PROVIDE | | | INFORMATION FOR THE DUCT WORK FOR THESE 2 PIZZA OVENS. | | | THE KITCHEN FAN SCHEDULE LISTED ON MKH-503 INDICATES | | | THE DUCT SIZE CONNECTION AS 6 INCH BUT THE DUCTWORK | | | SHOWN ON MKH-502 INDICATES THE DUCTWORK TO BE 8 INCH. | | | PLEASE EXPLAIN? | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2022-11-03 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-11-03 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-11-03 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2022-11-03 16:09:45 | 1ST REVIEW FMC | | | PERMIT: 22071259 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE THE PERMIT NUMBER FOR THIS A8.0.1 | | | THAT IS REFERENCED IN THE RESPONSE LETTER. IF THIS | | | ENCLOSURE IS LOCATED IN A PLENUM IT CANNOT BE ALLOWED | | | TO ???BREATHE WITH THE PLENUM AIR.??? THE IN LINE FAN | | | WILL NEED TO MEET THE REQUIREMENTS OF FMC 506.5.1.2 | | | | | | 506.5.1.2 IN-LINE FAN LOCATION. WHERE ENCLOSED DUCT | | | SYSTEMS ARE CONNECTED TO IN-LINE FANS NOT LOCATED | | | OUTDOORS, | | | THE FAN SHALL BE LOCATED IN A ROOM OR SPACE HAVING THE | | | SAME FIRE-RESISTANCE RATING AS THE DUCT ENCLOSURE. | | | ACCESS SHALL BE PROVIDED FOR SERVICING AND CLEANING OF | | | FAN COMPONENTS. SUCH ROOMS OR SPACES SHALL BE | | | VENTILATED | | | IN ACCORDANCE WITH THE FAN MANUFACTURER???S | | | INSTALLATION INSTRUCTIONS. | | | | | | 2) PROVIDE THE DOCUMENT THAT SHOWS THE TENANT ACCESS | | | AGREEMENT FMC 306.1 | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-10-18 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-18 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2022-10-18 14:42:53 | PLEASE ADDRESS THE COMMENTS FROM THE PREVIOUS REVIEWS | | | LISTED BELOW: | | | | | | 1) PROVIDE THE ARCHITECTURAL SHEETS CALLED OUT IN NOTE | | | 1. NOTE 2, PROVIDE A DETAIL DRAWING OF THIS ACCESS | | | DOOR. OR REFERENCE WHICH A SHEET THE DETAIL IS LOCATED. | | | | | | 2) ACCORDING TO THIS DESIGN FOR THE HOOD EXHAUST AND | | | DISHWASHER EXHAUST, THE DUCTWORK IS TRAVELING THROUGH A | | | FUTURE TENANT SPACE, MEDICAL OFFICE, PLEASE EXPLAIN HOW | | | THIS GREASE DUCT WILL BE ACCESSIBLE FOR CLEANING AND | | | MAINTAINING. FBC 107.3.5 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-09-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-07 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-07 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2022-09-07 12:55:55 | 2ND REVIEW FMC | | | PERMIT: 22071259 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | DRAWING 3 OF 4: KITCHEN HOOD EXHAUST FAN 2 HOUR RATED | | | SHAFT DETAIL: | | | | | | 1) PLEASE PROVIDE A MORE DETAILED DRAWING OF THIS RATED | | | BOX THAT WILL ENCLOSE THE KEF-1. EXPLAIN WHY THE FIRE | | | DAMPERS ARE IN THIS DESIGN. PROVIDE THE ARCHITECTURAL | | | SHEETS CALLED OUT IN NOTE 1. NOTE 2, PROVIDE A DETAIL | | | DRAWING OF THIS ACCESS DOOR. NOTE 8 STATES THE 2-HOUR | | | FIRE WRAP SHALL TERMINATE TO 2- HOUR GYPSUM BOARD | | | ENCLOSURE BUT THE INSTALLATION DETAIL FOR TRANSITION TO | | | RATED SHAFT DETAIL DOES NOT SHOW THIS. PLEASE PRESENT | | | CONSISTENT DETAILS. THE INSTALLATION DETAIL FOR | | | TRANSITION TO RATED SHAFT DETAIL DOES NOT SHOW THAT | | | NOTE 5 IS BEING USED, SHOW THE BANDING OR REMOVE THIS | | | NOTE 5. THERE IS A 6 ON THE DESIGN DRAWING BUT THIS | | | NUMBER 6 IS NOT LISTED, EXPLAIN WHAT THIS 6 IS | | | REFERENCING. FBC107.3.5 | | | | | | 2) ACCORDING TO THIS DESIGN FOR THE HOOD EXHAUST AND | | | DISHWASHER EXHAUST, THE DUCTWORK IS TRAVELING THROUGH A | | | FUTURE TENANT SPACE, MEDICAL OFFICE, PLEASE EXPLAIN HOW | | | THIS GREASE DUCT WILL BE ACCESSIBLE FOR CLEANING AND | | | MAINTAINING. FBC 107.3.5 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-08-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-18 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-18 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2022-08-18 11:35:16 | 1) PROVIDE THE FIELD APPLIED GREASE DUCT ENCLOSURE | | | SPECIFICATIONS. FMC 506.3.11.2 | | | | | | 2) PROVIDE DETAILS FOR THE KEF-1 HOOD EXHAUST FAN AND | | | HOW THIS INSTALLATION WILL MEET THE PROTECTION | | | REQUIREMENTS OF FMC 506.5.1.2 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
P |
Date |
2022-09-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-07 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-07 |
Time |
13:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2022-12-21 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-12-21 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-12-21 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-12-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-12-02 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-12-02 |
Time |
14:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-10-18 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-18 |
Time |
14:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-09-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-07 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-07 |
Time |
12:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-08-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-18 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-18 |
Time |
11:36 |
Sent To |
|
|
| Notes |
|
|