| Plan Review Stops For Permit 22071166 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2022-08-02 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-08-02 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-08-02 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2022-08-02 08:59:54 | ADDRESS APPROPRIATE FOR PROJECT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-10-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-10-19 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-10-19 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2022-10-19 14:18:01 | FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND | | | BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO | | | FILLING THE POOL WITH WATER. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-08-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-08-26 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-08-26 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2022-08-26 16:50:47 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SHOW COMPLIANCE WITH FBC-R4502.17.1 OUTDOOR SWIMMING | | | POOLS. OUTDOOR SWIMMING POOLS SHALL BE PROVIDED WITH A | | | BARRIER COMPLYING WITH R4501.17.1.1 THROUGH | | | R4501.17.1.14. | | | | | | 2) SECTION R403.9.3 OF THE 2020 ENERGY CONSERVATION | | | CODE REQUIRES HEATED POOLS TO HAVE COVERS TO REDUCE | | | HEAT LOSS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-10-27 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-10-27 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-10-27 |
Time |
08:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-09-22 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-09-22 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-09-22 |
Time |
08:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-08-07 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-08-07 |
Time |
18:52 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-08-07 |
Time |
18:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-10-27 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-10-27 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-10-19 |
Time |
16:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-10-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-10-19 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-09-07 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-08-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-08-26 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-07-27 |
Time |
07:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2022-10-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-10-26 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-10-26 |
Time |
10:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-09-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-09-13 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-09-13 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2022-09-13 16:54:27 | 1ST REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 22071166 | | | 9/13/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS 1 & 2: PLEASE SHOW THE LENGTH OF THE PIPING | | | RUNS AND TYPE AND NUMBER OF FITTINGS IN THE TDH | | | CALCULATIONS, AND PROVIDE THE PUMP CURVE ON THE PLAN | | | MARKED UP TO SHOW THE TDH AND FLOW RATE OF THE SYSTEM- | | | SECS. 4.4.9, 4.4.9.1 ANSI/APSP/ICC-7 & R4501.7.2 & | | | R4501.7.3 FBC RES. | | | | | | 2) SHEET 2: THE WATERWAY MAIN DRAIN AND COVER SPECIFIED | | | ON THE PLAN DOES NOT MATCH THE UPLOADED PENTAIR DRAIN | | | SUBMITTAL. PLEASE NOTE THE 160 GPM MAXIMUM FLOW RATE OF | | | THE SYSTEM EXCEEDS THE FLOW CAPACITIES OF THE TWO DRAIN | | | ASSEMBLIES- SEC. R4501.6.6 FBC RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-07-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-07-29 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-07-29 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2022-07-29 16:52:27 | 1ST REVIEW FBC- 2020 RES. PLUMBING | | | PERMIT- 22071166 | | | 7/29/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS 1 & 2: THE TDH CALCULATIONS INDICATE 35 FT. | | | LENGTHS FOR SUCTION AND PRESSURE PIPING HOWEVER BASED | | | ON THE POOL LAYOUT PLAN THE LENGTHS APPEAR GREATER THAN | | | 35 FT.- PLEASE CORRECT- SECS. 4.4.9, 4.4.9.1 | | | ANSI/APSP/ICC-7. | | | | | | 2) SHEET 2: PLEASE PROVIDE POOL EQUIPMENT ANCHORING | | | DETAILS- TYPES AND SIZES OF ANCHOR BOLTS OR TAPCONS- | | | SEC. R4501.22 FBC RES. | | | | | | 3) SHEET 2: REFER TO SEC. R4501.6.1 FBC RES AND SHOW | | | THE CURRENT YEAR EDITIONS OF THE DESIGN STANDARDS IN | | | EFFECT. | | | | | | 4) SHEET 1: A BACKFLOW DEVICE IS REQUIRED FOR THE | | | POTABLE WATER AUPPLY TO THE AUTOFILL- SECS. 608.3 AND | | | 608.3.17.4.1 FBC P. PLEASE PLACE A NOTE ON THE PLAN TO | | | SHOW COMPLIANCE. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-10-27 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-10-27 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-10-27 |
Time |
09:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-09-22 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-09-22 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-09-22 |
Time |
08:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-08-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-08-26 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-07-29 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2022-08-07 18:53:58 | ELECTRICAL PAGE APPROVED FOR SIGNATURE JLEAHY |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-08-04 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-08-04 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-08-04 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|