|
 |
 |
 |
 |
 |
Plan Review Details - Permit 22071160
| Plan Review Stops For Permit 22071160 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-09-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-09-22 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-09-22 |
Time |
15:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-09-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-09-06 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-09-06 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2022-09-06 10:36:44 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT A COPY OF THE ACTUAL TEST REPORTS FOR THE | | | SOUND INSULATION INCLUDING FLAME SPREAD AND SMOKE | | | DEVELOPED FOR THE APPLICABLE CONSTRUCTION CONDITIONS. | | | THE TEST REPORTS FOR THE PROPOSED UNDERLAYMENT SHALL BE | | | BASED ON THE CONCRETE SLAB THICKNESS AND ONY OTHER | | | EXISTING SITE CONDITIONS. | | | TEST REPORTS MAY BE BASED ON THE FOLLOWING ASTM'S: | | | E-84, E-90 & E-492. | | | - FBC 603.1 FLAME SPREAD - ASTM E 84-09 | | | | | | - FBC 1207.2 AIR-BORNE SOUND. ASTM E 90-04 | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | - FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E 492-09 | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-08-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-08-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-08-04 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2022-08-04 16:28:56 | FLOORING DOCUMENT PROVIDED 8/26/22. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-09-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-09-22 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-09-19 |
Time |
08:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-09-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-09-14 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-08-01 |
Time |
07:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2022-09-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-09-06 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-09-06 |
Time |
09:56 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |