| Plan Review Stops For Permit 22071059 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-12-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-12-01 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-12-01 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2022-12-01 13:26:13 | FBC-R4501.19 FINAL ELECTRICAL AND BARRIER CODE | | | INSPECTION SHALL BE COMPLETED PRIOR TO FILLING THE POOL | | | WITH WATER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2022-09-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-09-29 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-09-29 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2022-09-29 16:00:16 | FBC-R4501.19 FINAL ELECTRICAL AND BARRIER CODE | | | INSPECTION SHALL BE COMPLETED PRIOR TO FILLING THE POOL | | | WITH WATER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-10-24 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-10-24 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-10-24 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-09-02 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-09-02 |
Time |
10:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-12-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-12-01 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-10-12 |
Time |
06:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-09-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-09-29 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-08-16 |
Time |
13:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-10-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-10-17 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-10-17 |
Time |
12:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-08-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-26 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-26 |
Time |
09:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-10-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-10-17 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-10-17 |
Time |
12:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-08-24 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-08-24 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-08-24 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2022-08-26 09:35:18 | TDH CALCULATIONS AND PLUMBING PLANS ARE COPIES OF | | | DIGITALLY SIGNED AND SEALED CALCULATIONS AND PLANS. | | | VERIFIABLE DIGITAL SIGNATURES AND SEALS ARE REQUIRED- | | | FL. STAT. 471.025 & FAC 61G15-23.005. | | 2022-08-24 15:34:09 | SIGNATURE REVIEW FAILED | | | ALL DOCUMENTS/PLANS SUBMITTED AND ENGINEERED BY SYDNEY | | | KOVNER ARE COPIES OF A SEAL AND DIGITAL SIGNATURE. | | | | | | FS471/FS481 DOCUMENTS PREPARED BY ARCHITECT/ENGINEER OF | | | RECORD AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | DIGITALLY SEALED AND SIGNED OR PAPER SUBMITTALS ARE | | | REQUIRED TO BE SEALED AND WET SIGNED. | | | | | | PLEASE SUBMIT DIGITALLY SEALED AND SIGNED PLANS | | | FOLLOWING PROJECTDOX INSTRUCTIONS OR PROPERLY SIGNED | | | AND WET SIGNED ORIGINAL PAPER DOCUMENTS/PLANS | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-10-14 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-10-14 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-10-14 |
Time |
15:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-08-22 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-08-22 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-08-22 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2022-08-22 09:27:30 | 08/22/22 FAILED | | | | | | NEED TO PROVIDE THE SETBACK OF THE POOL EQUIPMENT. PER | | | CITY CODE, MECHANICAL EQUIPMENT CANNOT PROTURDE MORE | | | THAN 4 FT INTO ANY SETBACK | | | | | | ALEXANDER FOWLKES | | | [email protected] | | | 5618221431 |
|
|