Plan Review Details - Permit 22070933
Plan Review Stops For Permit 22070933
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2022-08-15 Cont ID  
Sent By ccole Date 2022-08-15 Time 06:55 Rev Time 0.00
Received By ccole Date 2022-08-15 Time 06:39 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-08-10 Cont ID  
Sent By ccole Date 2022-08-10 Time 14:36 Rev Time 0.00
Received By ccole Date 2022-08-10 Time 13:41 Sent To  
Notes
2022-08-10 14:38:221ST REVIEW FBC-2020 FUEL GAS
 PERMIT- 22070933
 8/10/2022
  
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) GAS RISER: THE PRINTED NAME, SIGNATURE, LICENSE
 NUMBER OF THE CONTRACTOR OR QUALIFIER SHALL BE ON THE
 DRAWING- SEC. 107.2.1 WPB, AND FL. STATUTES
 471.003(2)(H) & 471.025.
  
 2) GAS RISER: SHOW THE TYPE AND SIZE OF THE PIPE FROM
 THE METER TO THE TEE, AND THEN FROM THE TEE ONWARD
 (DESTINATION NOT SHOWN). REFER TO SECS. G2412.3 &
 G2412.4 FBC RES. AND PROVIDE THE FOLLOWING INFORMATION
 ON THE DRAWING PER SECS. G2412.3 & G2412.4 FBC RES.
 A) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS.
 B) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 C) TYPES AND SIZES OF PIPING.
 D) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 E) LOCATIONS OF REGULATORS, SHUTOFF VALVES.
 F) OUTLET PRESSURES AT REGULATORS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2022-08-15 Time   Rev Time 0.00
Received By lmarchan Date 2022-08-12 Time 08:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2022-08-10 Time   Rev Time 0.00
Received By cdecoeur Date 2022-08-09 Time 07:41 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2022-08-15 Cont ID  
Sent By ccole Date 2022-08-15 Time 06:55 Rev Time 0.00
Received By ccole Date 2022-08-15 Time 06:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2022-08-10 Cont ID  
Sent By ccole Date 2022-08-10 Time 14:38 Rev Time 0.00
Received By ccole Date 2022-08-10 Time 13:41 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2022-08-10 Cont ID  
Sent By ccole Date 2022-08-10 Time 14:38 Rev Time 0.00
Received By ccole Date 2022-08-10 Time 13:41 Sent To  
Notes
2022-08-10 14:39:06CONTRACTOR PLANS.